ASCON TECNOLOGIC - TLI 40 - OPERATING INSTRUCTIONS - 

PAG. 11

6.3 - GUARANTEE AND REPAIRS

 

The  instrument  is  under  warranty  against  manufacturing  flaws  or 
faulty material, that are found within 1

8

 months from delivery date.  

The  guarantee  is  limited  to  repairs  or  to  the  replacement  of  the 
instrument.  
The eventual opening of the housing, the violation of the instrument 
or  the  improper  use  and  installation  of  the  product  will  bring  about 
the immediate withdrawal of the warranty’s effects.  
In  the  event  of  a  faulty  instrument,  either  within  the  period  of 
warranty,  or  further  to  its  expiry,  please  contact  our  sales 
department to obtain  authorisation for sending the instrument to our 
company.  
The faulty product must be shipped to TECNOLOGIC with a detailed 
description  of  the  faults  found,  without  any  fees  or  charge  for 
Tecnologic, except in the event of alternative agreements. 

7 - TECHNICAL DATA

 

7.1 – ELECTRICAL DATA

 

Power supply: 24 VAC/VDC, 100... 240 VAC +/- 10%  
Frequency AC: 50/60 Hz 
Power consumption: 8 VA approx. 
Input/s: 1 input for temperature probes: tc J,K,S ; RTD Pt 100 IEC; 
PTC KTY 81-121  (990

 Ω

 @ 25 °C); NTC 103AT-2 (10K

 @ 25 °C) 

or  mV    signals  0...50  mV,  0...60  mV,  12  ...60  mV  or  normalized 
signals  0/4...20  mA,  0/1...5  V  ,  0/2...10  V  or  potentiometer  with 
resistance > 1 K

; 1 digital input for free voltage contact 

Impedance normalized signals input:  0/4..20 mA: 51 

;   

mV and V: 1 M

 

Output/s:  Up  to  4  digital  outputs.  Relay  SPST-NO  (5  A-AC1,  2  A-
AC3 / 250 VAC) ; or in tension to drive SSR (7mA/ 14VDC).  
Up to 1 (OUT1)  analogue output: 0/4 ..20 mA or 0/2 ..10 V. 
Auxiliary supply output: 12 VDC / 20 mA Max. or 2,5 VDC / 2,5 mA 
Max. for potentiometer input. 
Electrical life for relay outputs: 100000 operat. 
Installation category:  II 
Measurement category:  I 
Protection class against electric shock:  Class II  for Front panel 
Insulation:

 

Reinforced  insulation  between  the  low  voltage  section 

(supply and relay outputs) and the front panel; Reinforced insulation 
between the low voltage section (supply and relay outputs) and the 
extra  low  voltage  section  (inputs,  analogue  outputs,  SSR  outputs); 
analogue  and  SSR  outputs  optoisolated  respect  to  the  input.  50  V 
insulation between RS485 and extra low voltage section.

 

7.2 – MECHANICAL DATA

 

Housing: Self-extinguishing plastic, UL 94 V0 
Dimensions: 48 x 48 mm DIN, depth 98 mm 
Weight: 190 g approx. 
Mounting: Flush in panel in 45 x 45  mm hole 
Connections:  2 x 1 mm

2

 screw terminals block

Degree  of  front  panel  protection  :  IP  65  mounted  in  panel  with 
gasket 
Pollution situation: 2 
Operating temperature:  0 ... 50 °C 
Operating humidity: 30 ... 95 RH% without condensation 
Storage temperature: -10 ... +60 °C 

7.3  –  MECHANICAL  DIMENSIONS,  PANEL  CUT-OUT  AND 
MOUNTING [mm]

 

7.4 – FUNCTIONAL FEATURES 

Sampling  rate:  For  normalized  signals  or  potentiometer  input 
programmable from 8 to 64 sampl./sec. 
Measurement range: according to the used probe (see range table) 
Measurement  Resolution:  For  normalized  signals  or  potentiometer 
input  in  order  to  the  programmed  sampling  rate  as  32000  steps  (8 
sampl./sec.),  16000  steps  (16  sampl./sec.),  8000  steps  (32 
sampl./sec.), 4000 steps (64 sampl./sec.). 
Display resolution: according to the probe used  1/0,1/0,01/0,001 
Overall accuracy: +/- 0,15 % fs  
Max.  cold  junction  compensation  drift  (in  tc)  :  0,04  °C/°C  with 
operating temperature 0 ... 50 °C after warm-up of 20 min. 
Sampling rate: 130 ms. 
Serial Interface : RS485 insulated 
Communication protocol: MODBUS RTU (JBUS) 
Baud rate: Programmable from 1200 ... 38400 baud 
Display: Display: 4 digit, Red h 12 mm  
Compliance:  ECC  directive  EMC  2004/108/CE  (EN  61326),  ECC 
directive LV 2006/95/CE (EN 61010-1) 

7.5

 - 

MEASURING RANGE TABLE 

INPUT 

“dP” = 0 

“dP”= 1, 2, 3 

tc J 

“HCFG” = tc 

“SEnS” = J 

-160 ... 1000 °C

- 256 ... 1832 °F

-160.0 ... 999.9 °C

-199.9 ... 999.9 °F

Содержание TLI40

Страница 1: ...6 PROBLEMS MAINTENANCE AND GUARANTEE 6 1 ERROR SIGNALLING 6 2 CLEANING 6 3 GUARANTEE AND REPAIRS 7 TECHNICAL DATA 7 1 ELECTRICAL DATA 7 2 MECHANICAL DATA 7 3 MECHANICAL DIMENSIONS PANEL CUT OUT AND MO...

Страница 2: ...value has been programmed push key P once more the new value will be memorised and the display will show only the code of the selected parameter By using the UP or DOWN keys it is then possible to se...

Страница 3: ...ked as instrument disconnecting device which interrupts the power supply to the equipment It is also recommended that all the electrical circuits connected to the instrument must be protect properly u...

Страница 4: ...ument is switched on by using the U key that has been suitably programmed see par U key with function USrb r Pic or through the suitably programmed digital input see par digital input with function dI...

Страница 5: ...d in sec and the alarm will be activated only after the elapsing of that time ALARM LATCH the alarm output may behave in two different ways depending on the value added to par Abn 0 ALARM NOT LATCHED...

Страница 6: ...eter input it is possible to set the zero value with this function By closing the contact connected to the digital input assuming the value measured in that instant as 0 r P0P For the instruments equi...

Страница 7: ...tput 3 Par Description Range Def Note 20 O3F Functioning of output 3 ALno ALnc Ser OFF ALno Group O4 parameters relative to output 4 Par Description Range Def Note 21 O4F Functioning of output 4 ALno...

Страница 8: ...to a high value when the material to be measured is particularly light reflective and reduce it when the surface is especially dark non reflective keeping in mind however that for most materials the r...

Страница 9: ...ARM The alarm is activated when the process value goes below the alarm threshold set on parameter AL1L or goes higher than alarm set on parameter AL1H Ab1 ALARM AL1 FUNCTION This permits definition of...

Страница 10: ...r the instruments equipped with potentiometer input with this function it is possible to set the points of measure of the potentiometer by means of an auto ranging procedure through which the paramete...

Страница 11: ...ection class against electric shock Class II for Front panel Insulation Reinforced insulation between the low voltage section supply and relay outputs and the front panel Reinforced insulation between...

Страница 12: ...99 99 99 1 999 9 999 0 50 mV HCFG UoLt SEnS 0 50 1999 9999 199 9 999 9 19 99 99 99 1 999 9 999 0 60 mV HCFG UoLt SEnS 0 60 1999 9999 199 9 999 9 19 99 99 99 1 999 9 999 12 60 mV HCFG UoLt SEnS 12 60...

Отзывы: