Installation Guide
teleCARE IP
Figure 103. Pull cord module electrical connections and address setting
Note:
The 4-pole connector terminals required for the room bus connections is not supplied
with the switch module. It is available as accessories and must be ordered separately.
6.8.2 Assembling and Attaching the Pull Cord
It is important to assemble and attach the pull cord to the pull switch module correctly to ensure the cord
is securely attached and that the “safety break” mechanism works reliably. The following illustrations
show how to attach the pull cord:
Figure 104. Assembling and attaching the pull cord
4-Pole Connector
for Room Bus
Dip Switch
for Setting the
Room Bus
Address
0, 1, 2, or 3
Connector
for the
Speech Module
Not supported
with UL 2560
systems