7 Faults and their Rectification
7.1 Fault indication on the display
Short circuit temperature sensor, hob temperature too low < -50°C
Temperature of hob too high, hob temperature sensor interrupted > 260°C
No pan on the hob (pan too small for the hob)
Wrong pan on the hob, short circuit of the induction coil
Heat sink temperature > 100°C or temperature sensor of heat sink short circuited
Heat sink temperature > -15°C or temperature sensor of heat sink interrupted
Potentiometer is missing or defective: Incorrect value (greater than 10.75 kOhm)
Electronics OK, potentiometer at 0 position
Signal for external indication is missing (external indication disconnected or
SW1/3 switched on)
Switch-on after disconnection of AC phases L1 and L3 to zero < 150 V,
(if L2 drops out, appliance continues to function at reduced power)
Failure of standard I/O DEVICE 1 or 2
Warning: DC current > 350 mA (too many or wrong fans)
Warning: Fan not connected or blocked