4
4.2.1 Free-standing appliances
The connections can be made from below or from the rear from a closed installation space. If connected
from below, the pipe length must be 50 mm above the floor surface. If connected from the rear, the
installation pipes must not protrude into the appliance.
4.2.1.1
Connection from the rear when appliance on a plinth
The penetrations are to be made in compliance with the known DIN and VDE regulations.
The connections can be through the rear wall (see illustration for dimensions).
Front view
– position of the penetrations for connections when the appliance is on a plinth
4.2.2 Wall/table mounted appliance - attached to an installation wall, cantilever or wall-mounted frame
When attaching the appliance to an installation wall, cantilever or wall-mounted frame (ACC 881), the
appliance connections from below or from the rear must be used.
4.2.3 Wall/table-top appliances – connected through the rear wall
On the right-hand side in the rear corner is a bracket that is screwed on with downwards penetration that
covers the access to the installation channel to the rear. Remove the bracket, turn it through 180° and
screw it back on so that the penetration in the bracket now frees up access to the rear and covers the
downwards access.
5 Proper Use of the Appliance
5.1 Operational start-up
Remove the protective film before placing into operation.
Clean the appliance with dilute soap solution.
5.2 Check functions
Check the supply pressure (flow pressure): Connect the pressure gauge to the pressure measuring
nipple of the main gas pipe.
Check whether the nozzles appropriate to the gas supply have been installed (see conversion instructions).
Bring the burners into operation and check whether the allowable supply pressure is maintained.
Close the sealing screw of the pressure measuring nipple again once the measuring is finished!