3.1 START FREQ
The start frequency of the sweep cycle.
3.2 STOP FREQ
The stop frequency of the sweep cycle. If it is lower that the
start frequency, the sweep runs "backwards" (from the higher
to the lower frequency).
3.3 SWEEP FREQ
The sweep frequency can be adjusted between 0.1 Hz
(equivalent to 10 sec sweep cycle duration) and 10 Hz (0.1 sec
sweep cycle duration or 10 sweep cycles per second).
3.4 SWEEP MODE
This setting controls the behavior after a sweep cycle is
complete.
LOOP
restarts the cycle again with the start
frequency,
SWING
lets it run back from the stop to the start
frequency.
28
Содержание AE20125
Страница 1: ...20125 10 MHz Sweep DDS Function Generator Assembly and Operation Manual...
Страница 2: ...REV 3 1 EN 2015 Ascel Electronic...
Страница 23: ...Finished Component Side Finished Solder Side without the LCD LCD Mounting 16...
Страница 30: ...Operation Menu Structure 23...
Страница 40: ...Circuit Diagram Part 1 2 33...
Страница 41: ...Part 2 2 34...
Страница 51: ......