4.3.1 Electrical specifications of the installation
MOD.
OPTIONS
POWER
SUPPLY
MAX. ELECTRIC
POWER
AMP.
(A)
NET
WEIGHT
G-OEM-500
(W/B/DD/F/SA)
230V 1N~ 50/60Hz
3,4 kW
15
54 kg
GM-OEM-500
GT-OEM-500
G-OEM-500
(W/B/DD/F/SA)
UK
230V 1N~ 50/60Hz
2,8 kW
12,2 A
GM-OEM-500
GT-OEM-500
G-OEM-510
(W/B/DD/F/SA)
230V 1N~ 50/60Hz
6,2 kW
27 A
60 kg
GM-OEM-510
230V 3~ 50/60Hz
16,7 A
GT-OEM-510
400V 3N~ 50/60Hz
10,7 A
G-OEM-510
(W/B/DD/F/SA)
UK
230V 1N~ 50/60Hz
6,2 kW
27 A
GM-OEM-510
230V 3~ 50/60Hz
16,7 A
GT-OEM-510
400V 3N~ 50/60Hz
10,7 A
4.3.2 Voltage Configuration of the machine
The voltage configuration of the machine is stipulated on the nameplate. If the mains voltage supply
is not the same as that stipulated on the machine, there is a terminal box from which the different
voltage options can be configured
(230V 1N~, 230V 3~ or 400V 3N~).
Fig. 6, 7, 8
In the event of a change, the supplier must be notified to ensure that the machine’s guarantee remains
valid. To access the terminal holder, undo the machine’s cover.
ONLY AUTHORISED PERSONNEL may change the electrical
configuration. Users may not tamper with the machinery.
4.4 Hydraulic connection
The new hoses supplied with the appliance should be used (do not reuse old hoses).
Before connecting the machine to the water supply, the water quality should be tested.
Recommended water quality:
Water temperature (T):
max. 60
⁰
C
Total water hardness:
5 – 10
⁰
fH (French degrees)
pH:
6.5 - 7.5
7 – 14
⁰
eH (English degrees)
Impurities:
Ø < 0.08 mm
9 – 18
⁰
dH (German degrees)
Chlorides:
max. 150 mg/l
Conductivity:
400 - 1,000 µS/cm
Cl:
0.2 - 0.5 mg/l
If the water hardness is more than 10
⁰
fH (French degrees), a descaler must be installed.
In addition to water quality, the pressure of the mains water supply must be considered. This is
important to ensure the machine operates correctly.
Required water pressure:
Min.
Max.
DYNAMIC
PRESSURE
bar
kPa
kg/cm
2
psi
bar
kPa
kg/cm
2
psi
2
200
2,03
29
4
400
4,07
58,01
If the water pressure is higher than the recommended pressure, a pressure regulator must be mounted
at the output
Fig. 2.
If the mains water pressure is lower than the recommended pressure, a pressure
pump should be mounted at the mains water supply
Fig. 3
.
Fig. 2
. Direct connection of water input hose.
5
Fig. 3
. Pressure pump connection.
S → SHUT-OFF COCK
F → FILTER
H → WATER HOSE
6
E → ELECTROVALVE
B → ELECTRIC PRESSURE PUMP
5
31mm in diameter and must be installed in accordance with AS/ NZ3500.2 (drainage) by means of coupled
connection to a DN50 or larger pipe
6
For Australia, watermark certified inlet hose and backflow prevention device. Must be installed in
accordance with AS/NZS3500.1 (water service supply) including installation of the supplied backflow
prevention device.
Содержание Easy GT 500
Страница 4: ...4 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 Fig 8...
Страница 6: ...6 Fig 11 Modelo Mod le Model Modell Modello Mode Model Modell GT GT OEM 500 GT OEM 500 SOFT...
Страница 136: ...RU 136 1 G OEM 500 1 1 2 2 3 1 2 3 4 4 1 1 0 1 2 3 3 1 1 4 4 1 5 3 4 6 1 0 1 1 4 2 3 1 1 2 3 4...
Страница 140: ...RU 140 2 2014 35 2014 30 2006 42 2011 65 5 40...
Страница 142: ...RU 142 4 4 1 4 2 4 3 H07RN F 3...
Страница 144: ...RU 144 5 C T 25 C 40 C T 60 C 60 3 4 4 5 4 680 1 5 4 5 4 6 Rinse Aid 4 7 Rinse Aid...
Страница 145: ...RU 145 4 8 Detergent 1 DETERGENT CONNEXION 4 9...
Страница 149: ...RU 149 5 2 5 2 1 o o o o o o 5 2 2 5 2 3 40 50 5 2 4 5 2 5...
Страница 150: ...RU 150 6 50 80...
Страница 151: ...RU 151 6 1 8 E1 0 5 2 E2 0 5 2 E3 0 5 2 E4 0 5 2 E5 0 5 2 7 2012 19 EU...