User’s
Manual 237
Default
23
Command Mode
Global Configuration
Usage Guidelines
The command specifies the facility type tag sent in syslog messages. (See RFC 3164.) This type has no
effect on the kind of messages reported by the switch. It may be used by the syslog server to sort messages
or to store messages in the corresponding database.
Example
Console(config)#
logging facility 19
Console(config)#
16.85 logging history
This command limits syslog messages saved to switch memory based on severity. The no form returns the
logging of syslog messages to the default level.
Syntax Description
logging history {flash | ram}
level
no
logging history {flash | ram}
flash
Event history stored in flash memory (For example, permanent memory).
ram
Event history stored in temporary RAM (For example, memory flushed on
power reset).
level
One of the levels listed below. Messages sent include the selected level down
to level 0. (Range: 0-7)
The following table gives information on each level name, number and general description.
Level Name
Level
Description
debugging 7
Debugging
messages
informational 6
Informational
messages
only
notifications
5
Normal but significant condition, such as cold start
warnings
4
Warning conditions (such as, return false,
unexpected return)
Errors
3
Error conditions (such as, invalid input, default
used)