background image

取扱説明書

 

User’s  Manual 

AVSDV-T                                                                                                                                                                                                                                                                                       

 

④固定方法 

Mounting

⑦チューブ径

 Connection tubing size

⑥耐薬仕様

 Chemical-resistant

※6

T

AVSDV

10

Super 300 Type Pillar Fitting

Flowell 20 series

  T

 

※3

  F

 

※4

25

□30

□40

□50

□60

   03

※2

9.53 x 6.35

6.35 x 4.35

0

90°

ロック式

90°

LockType

1

ノンロック式

Non-Lock

Type

  R

 

※4

  N

 

※4

M

I

インチ 

ミ  リ

Oリング材質

※7

O-ring

台座 Base plate

(方向1 Direction 1)

台座 Base plate

(方向2 Direction 2)

1

Tube

Flare Type

Rc

2

180°

ロック式

18

LockType

Millimeter

Inch

Super Type Pillar Fitting

1

カルレッツ

®

 6190

Karlez

®

 6190

②接続方法

 Connection

①本体材質

 Body Materials

※1

A

2

6

S

   2

※5

③規格

 Tubing Standard

金属部品コート

Metal Coating

0

V

1

0

FKM

EPDM

3

×

0

1

0

1

バイフロン

®

 F 

※8

Viflon

®

 F

×

×

19.05 x 15.88

19 x 16

12.70 x 9.53

12 x 10

   10A

※9

12

19

×

9.53 x 6.35

25.40 x 22.20

3 x 2

6 x 4

10 x 8

10 x 8

25 x 22

3.18 x 1.6 

PFA

T

PTFE

06

⑤ハンドルタイプ

 

Handle type

※5

E

F

K

FNPT

Flowell 60 series

T

-

作動

 Actuation

トグル式

 Toggle

流 体 方 向

Flow direction

流 体 方 向

Flow direction

SHUT

OPEN

SHUT

OPEN

SHUT

OPEN

④  型式選定   

How to select types

 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

型式選定例

Ordering code example

AVSDV-TAFI20V006

AVSDV-TTSM12E119

      下さい。

      “Body material”.tubing size “03”,only “A”can be 

※1 In the case of the connection is “3”,“F”, remove 

※2 In the case the tube diameter is “03”,F,T,R and N 
      connection is not available.

      only “I(Inch)” can be selected for the “Tubing Standard“.
※5 In the case of Mounting “2”there is some possibility
      of that the mounting holes are hidden by some 

      is a strong chemical, strong acid etc.

※4 In the case of the connection is “F”,“R”or “N” , 

      connection from top side,  and hard to be mounted.
※6 Please consult us for the specification if the medium

※7 O-rings are not wetted.
※8 ”Viflon” is the Terpolymerization Fluorocarbon

※1  接続方法 “3” 、“F”(チューブ径 “3”を除く)の場合、本体
      材質はAのみ選択できます。その他の接続の場合、本体

※2 チューブ径が “03”の場合、接続方法はF、T、R、Nは選択

※3  Tubeの外径、内径サイズは接続方法・Tubeサイズをご参照

※4 接続方法“F” 、“R” 、“N”の場合は、規格 I“(インチ)”のみ
       選択できます。
※5  固定方法 “2” の場合、接続方法によっては接続部が

   材質はTのみです。

      できません。

※7 Oリングは接液しません。

※8 バイフロン

®

F は耐酸用三元系弗素ラバーです。

※9 接続方法は“3” と“F”のみ選択できます。

※3 Please refer to “Connection・ tube”size  for diameter

※9 Connection suitable only “3”and“F”.

      selected for the “Body material”. In the case of the 
      other connection, only “T”can be selected  for the “Body 

      ご注意ください。

      material”.

       の台座固定用穴と干渉する場合があります。

※6  使用流体が強酸等の場合にはご相談ください。

      of “Tube“.

      Elastomers.

□50

□60

03

06

10A

10

12

19

25

PTFE

PTFE

PTFE

PTFE

PTFE

PTFE

PTFE

PTFE

PTFE

PTFE

PTFE

PTFE

PTFE

PTFE

PTFE

PTFE

PTFE

PTFE

PTFE

PFA

PFA

PFA

PFA

PFA

PFA

PFA

PFA

PFA

PFA

PFA

PFA

PTFE

PTFE

PTFE

PTFE

PTFE

PTFE

PTFE

PTFE

PTFE

PTFE

PTFE

PTFE

PTFE

PTFE

PTFE

R

Rc

N

FNPT

□30

□40

● 本体材質・接続方法 組合せ

 

Body materials ・ Connection combination

3

Super 300 Type Pillar Fitting

F

Flare Type

T

Tube

接続方法

 Connection

2

Flowell 20 series

6

Flowell 60 series

S

Super Type Pillar Fitting

Содержание Dymatrix AVSDV-T

Страница 1: ...ve Serial No DTS033 04 General cautions Part names Specifications How to select types Dimension How to operate Technical data How to installation How to piping Check items Causes of defects and how to...

Страница 2: ...User s Manual AVSDV T 1 General cautions 1 2 AV V 029 EJ N2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 1 2...

Страница 3: ...User s Manual AVSDV T 2 1 1 AV V 029 EJ N2 2 3 4 5 6 1 2 3 4...

Страница 4: ...alve unable to seal 4 Please contact us when use for the fluid containing the crystalline substance It would make the valve unable to seal 5 Use the products within the range of working pressure shown...

Страница 5: ...nding on the working condition If cavitations are observed review the fluid pressure and piping design 3 Do not use the valve in negative pressure It can be damaged 4 Handle the products carefully to...

Страница 6: ...ser s Manual AVSDV T 5 Part names Body Diaphragm Actuator O O ring Metal parts SUS304 SUS304 PTFEcoating PTFE PP PVDF FKM EPDM Viflon F Kalrez 6190 Parts Chemical resistant Wetted parts 0 1 PFA or PTF...

Страница 7: ...c pressure 23 0 0 25 0 36 25psi Leakage Rate 3 Back Pressure Ambient Temperature Installation direction Connection 5 Orifice diameter CV 4 5 Cv value Items Actuation Medium Temperature Proof Pressure...

Страница 8: ...F T R and N connection is not available only I Inch can be selected for the Tubing Standard 5 In the case of Mounting 2 there is some possibility of that the mounting holes are hidden by some is a st...

Страница 9: ...Rc FNPT inch 50 72 72 90 110 50 60 89 5 129 5 158 5 22 34 39 112 174 227 5 111 173 5 227 112 175 228 5 30 Size 30 G 5 107 106 107 E 144 F 143 T 7 145 B 40 C 106 5 D 25 5 84 5 18 40 Standard A Flowell...

Страница 10: ...r 300 Type Pillar Fitting Flare Type 3 1 Secifications only for the PTFE Body 2 Secifications only for the PFA Body Super 300 Type Pillar Fitting Flare Type 3 It is reference value 1 PTFE 2 PFA Super...

Страница 11: ...19 15 8 25 4 22 2 12 10 25 22 12 70 9 53 19 05 15 88 12 7 9 5 6 4 10 8 inch 6 35 4 35 9 53 6 35 3 18 2 18 6 35 3 95 9 53 6 33 Flowell 20 series Flowell 60 series 06 10 12 19 25 6 4 10 8 12 10 19 16 25...

Страница 12: ...wn in parallel Upstream side 2 Valve is opened when Handle is raised to vertical and handle is locked 1 2 3 Non Lock Type 1 Valve is closed by spring when Handle is knocked down in parallel Upstream s...

Страница 13: ...Handle is knocked down in parallel Upstream side 2 Valve is opened when Handle is knocked down in parallel downstream side and handle is locked Upstream Downstream Upstream Downstream Status Close St...

Страница 14: ...Manual AVSDV T 13 Technical date Working pressure Back pressure Differential pressure Flow rate 2 The data shown here is the experimental values and the reference values 1 Cv B 2 1 The data of B type...

Страница 15: ...direction of passage and then fix the product to the panel by hand Insert the nut again from the top of the handle and tighten the nut while the panel is pinched to secure the product in firm positio...

Страница 16: ...User s Manual AVSDV T 15 How to piping Flowell 20 series 1 2 Flowell 60 series Super Type Pillar fitting Super 300 Type Pillar fitting Flare Type...

Страница 17: ...he inner surface of the tube Insert the tube provided with the ring into the main body by hand Turn nut up to the required clearance by spanner after tightening by hand firmly To check the tightness o...

Страница 18: ...check them at least once a year When finding any problem or trouble call us Check points Check items Actuator Appearance flaw crack distortion discoloration Unusual noise while the valve opens and clo...

Страница 19: ...kage in the fully closed position The diaphragm is abraded Replace the valve Flaw in the diaphragm or body Foreign matter is caught in the valve Outer leakage from the valve The cap nuts are loose Ret...

Страница 20: ...e of product improvement 2020 12 v04 110 0005 3 24 6 21 TEL 03 5826 8832 FAX 03 3834 7592 For inquiries contact Head Office Overseas Department Tel 81 3 5826 8831 Fax 81 3 3834 7592 21st Floor Ueno Fr...

Отзывы: