![Asahi KASEI AK4458 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/asahi-kasei/ak4458/ak4458_general-description-manual_2980215014.webp)
[AK4458]
014011794-E-01
2015/08
- 14 -
■
Slow Roll-Off Filter Characteristics
Slow Roll-Off Filter Characteristics
(fs = 44.1kHz)
(Ta=-40
105
C; AVDD=3.0
5.5V, TVDD=1.7
3.6V; Normal Speed Mode; DEM=OFF;
SLOW bit = “1”, SD bit=“0”)
Parameter
Symbol
Min.
Typ.
Max.
Unit
Digital Filter
Pass band (
Note 20
)
0.05dB
PB
0
8.1
kHz
3.0dB
PB
18.2
kHz
Pass band Ripple (
Note 17
)
PR
-0.043
0.043
dB
Stop band (
Note 20
)
SB
39.2
Stop band Attenuation (
Note 19
)
SA
73
dB
Group Delay (
Note 18
)
GD
-
6.3
-
1/fs
Frequency Response
(
Note 19
)
0.05dB
-
0
8.1
kHz
Digital SCF
(
Note 19
)
Frequency Response: 0
20.0kHz
-5
0.1
dB
Slow Roll-Off Filter Characteristics
(fs = 96kHz)
(Ta=-40
105
C; AVDD=3.0
5.5V, TVDD=1.7
3.6V; Double Speed Mode; DEM=OFF; SLOW bit = “1”,
SD bit=“0”)
Parameter
Symbol
Min.
Typ.
Max.
Unit
Digital Filter
Pass band (
Note 20
)
0.05dB
PB
0
17.7
kHz
3.0dB
PB
39.5
kHz
Pass band Ripple (
Note 17
)
PR
-0.043
0.043
dB
Stop band (
Note 20
)
SB
85.3
Stop band Attenuation (
Note 19
)
SA
73
dB
Group Delay (
Note 18
)
GD
-
6.3
-
1/fs
Frequency Response
(
Note 19
)
0.05dB
PB
0
17.7
kHz
Digital SCF
(
Note 19
)
Frequency Response: 0
40.0kHz
-5
0.1
dB
Slow Roll-Off Filter Characteristics
(fs = 192kHz)
(Ta=-40
105
C; AVDD=3.0
5.5V, TVDD=1.7
3.6V; Quad Speed Mode; DEM=OFF; SLOW bit = “1”,
SD bit=“0”)
Parameter
Symbol
Min.
Typ.
Max.
Unit
Digital Filter
Pass band (
Note 20
)
0.05dB
PB
0
35.5
kHz
3.0dB
PB
79.0
kHz
Pass band Ripple (
Note 17
)
PR
-0.043
0.043
dB
Stop band (
Note 20
)
SB
171
kHz
Stop band Attenuation (
Note 19
)
SA
73
dB
Group Delay (
Note 18
)
GD
-
6.3
-
1/fs
Frequency Response
(
Note 19
)
0.05dB
PB
0
35.5
kHz
Digital SCF
(
Note 19
)
Frequency Response: 0
80.0kHz
-5
0.1
dB
Note 20. The pass band and stop band frequencies scale with fs. For example, PB=0.185×fs, SB=0.888×fs.