4
5
CONTROL PADS ON THE DEHUMIDIFIER
Control pads
3
When you push the button to change
operation modes, the unit will make
a beep sound to indicate that it is
changing modes.
NOTE:
The control panel of the unit you purchased may be slightly different according to the
models.
Fig.1
2
Humidity Set Control Pads
: Down/Up Pads
TIMER Set Control Pads
Use the Up/Down pads to set the Auto start and
Auto stop time from 0.0 to 24.
The humidity level can be set within a range of
35%RH(Relative Humidity) to 85%RH(Relative
Humidity) in 5% increments.
For drier air, press the pad and set to a lower
percent value(%).
For damper air, press the pad and set a higher
percent value(%).
CONTROL PADS ON THE DEHUMIDIFIER
Other features
Bucket Full Light
Glows when the bucket is ready to be
emptied, or when the bucket is removed
or not replaced in the proper position.
When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue
to run until the frost disappears.
NOTE:When Auto defrosting operation,the unit may
make a voice of refrigerant flowing,it is normal.
Auto Defrost
Wait 3 minutes before resuming operation
After the unit has stopped, it can not be restart
opertation in the first 3 minutes. This is to protect
the unit. Operation will automatically start after
3 minutes.
Setting the Timer
When the unit is on, first press the Timer
button, the Timer Off indicator light
illuminates. It indicates the Auto Stop
program is initiated. Press it again the
Time On indecator light illuminates.It
indicates the Auto Start is initiated.
When the unit is off, first press the Timer
button, the TIMER ON indicator light
illuminates. It indicates the Auto Start
program is initiated. Press it again the
Time Off indecator light illuminates.It
indicates the Auto Stop is initiated.
Press or hold the UP or DOWN pad to
change the Auto time by 0.5 hour incre-
ments, up to 10 hours, then at 1 hour
increments up to 24 hours. The control
will count down the time remaining until
start.
The selected time will register in 5 seconds
and the system will automatically revert
back to display the previous humidity
setting.
When the Auto start & Auto stop times are
set, within the same program sequence,
TIMER ON OFF indicator lights illuminate
identifying both ON and OFF times are
now programmed.
Turning the unit ON or OFF at any time or
adjusting the timer setting to 0.0 will cancel
the Auto Start/Stop function.
When LED display window displays the
code of P2, the Auto Start/Stop function
will also be cancelled.
Display
Shows the set % humidity level from 35% to 85% or auto
start/stop time (0~24) while setting, then shows the actual
(
±
5% accuracy) room % humidity level in a range of
RH(Relative Humidity) to 90%RH(Relative Humidity).
Error Codes and Protection Codes:
AS
- Humidity sensor error--Unplug the unit and plug it back
in. If error repeats, call for service.
ES
- Temperature sensor error-- Unplug the unit and plug it
back in. If error repeats, call for service.
30%
5
Timer Pad
Press to initiate the Auto start and Auto stop feature,
in conjuction with the and key pads.
Auto Shut Off
The
shuts off when the bucket is full,
or when the bucket is removed or not replaced in
the proper position.When the setting humidity is
reached, the unit will be shut off automatically.
For some models,the fan motor will continue
operating.
dehumidifier
Auto-Restart
If the unit breaks off unexpectedly due to the power cut,
it will restart with the previous function setting automa-
tically when the power resumes.
1
4
Power Pad
Press to turn the dehumidifier on and off.
1
2
3
4
5
6
7
Unit operation on
indicator light
8
High fan
indicator light
Timer on/off
indicator light
Ion operation on
indicator light
Bucket full
indicator light
Continuous
operation on
indicator light
Dryer operation
on indicator light
Smart dehumidifying
operation on indicator
light
Mode Pad
Press to select the desired operation mode from
Dehumidifying,Dryer,Continuous dehumidifying and
Smart dehumidifying.
NOTE: Dryer and Smart dehumidifying modes are
optional.
6
Turbo Pad
7
Ion Pad(optional)
Press to activate the ionizer. Anions ar automatically
generated by ionization. The anions deactive the
airborne chemical vapors and dust particles. Press
it again to stop the function.
Control the fan speed. Press to select either High
or Normal fan speed. Set the fan control to High for
maximum moisture removal. When the humidity has
been reduced and quiet operation is preferred, set
the fan control to Normal.
8
P1
- Unit is defrosting-- Allow the unit time to automatically
defrost. The protection will clear after the unit self defrosts.
P2
- Bucket is full or bucket is not in right position-- Empty
the bucket and replace it in the right position.
E3
- Unit malfunction-- Unplug the unit and plug it back in. If
error repeats, call for service.
EC
-Refrigerant leakage detection-- With this new technology,
the display area will appear EC when the unit detects
refrigerant leakage ,call for service.
Smart dehumidifying mode(optional)
At smart dehumidifying mode, the unit will automatically
control room humidity in a comfortable range 45%~55%
according to the room temperature. The humidity setting
function will be invalid.
NOTE: When the compressor startups or stops
running,the unit may make a loud voice,it is normal.