1. 

Introduction 

This  manual  is  for  overall  settings  of  cameras  with  Camera  Link.  Please  refer  to  the  camera 
instruction for more details of cameras. 
This manual is especially for the following model:   

Table 1-1: Target Model 

Model 

Pixels 

Frame Rate 

ARTCAM-991SWIR-TEC-CL 

0.32M 

137fps 

 

2. 

Device and System Requirements 

To use a Camera Link camera, the following devices and software are required. Please have them 
prepared before starting up the camera. 

Table 2-1: Minimum Requirements 

Item 

Note 

Camera Link Frame Grabber Board 

Compatible with Base Configuration 

Viewer Software 

Software accompanying with grabber board, 
or ArtMeasure 

Serial Communication Software

 

e.g. Tera Term 

PC 

Any which can adopt items mentioned above. 

Camera 

 

Camera Link Cable 

The connector joining to camera should be SDR. 

AC Adapter

 

Please use the AC adapter we offer 

 
All the settings in this manual are under the condition with following devices which we recommend. 
While using other devices, users could adapt settings correspondent to the devices. 

Table 2-2: Device and System recommended 

Item 

Recommendation 

Camera Link Frame Grabber Board 

PIXCI®EB1 (Manufactured by EPIX) 

Viewer Software 

XCAP for Windows Lite 

Serial Communication Software

 

Tera Term 

 
Operation has been confirmed using the following framegrabbers and software combinations. 
 

Table 2-3: Tested Framegr Software 

Manufacturer 

Product name + software 

NI 

NI PCIe-1433 + NI MAX 

AVAL 

APX-3318 + AcapLib2Viewer 

Dalsa

 

Xcelera-CL PX4 Full + CamExpert 

EPIX 

PI XCAP 

  Tested CameraLink cable length: 2m 

 

 

 

Содержание ARTCAM-991SWIR-TEC-CL

Страница 1: ...2004 2021 ARTRAY Co Ltd 991SWIR TEC CL Camera Link Setting Manual 1 Rev 1 00 ARTCAM 991SWIR TEC CL Camera Link Setting Manual rev 1 00...

Страница 2: ...of the product 5 5 2 Communication Method 5 5 3 Command Format 5 5 4 List of Commands 6 5 5 Commands Details 7 5 5 1 Reset 7 5 5 2 Shutter 7 5 5 3 Gain 8 5 5 4 Temperature Control 8 5 5 5 Mirror 9 5 5...

Страница 3: ...ure Serial Communication Software e g Tera Term PC Any which can adopt items mentioned above Camera Camera Link Cable The connector joining to camera should be SDR AC Adapter Please use the AC adapter...

Страница 4: ...tified Grayscale 63 000MHz 3 2 Resolution The following table shows the maximum pixels of this camera Table 3 2 Resolution Model Horizontal Pixels Vertical Pixels ARTCAM 991SWIR TEC CL 640 512 4 Conne...

Страница 5: ...Please be sure to use half width characters of ASCII code Table 5 2 Command Format 1 2 3 4 5 6 Format cmd opt val CR or LF or CR LF Details 1 One letter which represents the main purpose of the comman...

Страница 6: ...ands Function cmd opt val Description Reset x Reset camera Shutter i v O Shutter speed setting Gain g v O Gain setting Temperature Control t v Sensor Temperature readout C vf FPGA Temperature readout...

Страница 7: ...ra 1 2 Format x Details 1 x Reset 2 Line feed code Response Normal OK Abnormal NG Note Resets camera 5 5 2 Shutter Table 5 5 Shutter Speed Settings 1 2 3 4 5 6 Format i v val Details 1 i Shutter 2 Del...

Страница 8: ...ntrol Table 5 7 Sensor Temperature Readout 1 2 3 4 Format t v Details 1 t Temperature control 2 Delimiter 3 v Option Sensor temperature readout 4 Line feed code Response Normal temperature Abnormal NG...

Страница 9: ...e disable vertical mirror Table 5 10 Mirror horizontal 1 2 3 4 5 6 Format m H val Details 1 m Mirror 2 Delimiter 3 H Option Horizontal 4 Delimiter 5 0 disabled 1 enabled 6 Line feed code Response Norm...

Страница 10: ...onse Normal Version 202012041730 example Abnormal NG Note To show firmware version 5 5 7 Peltier Table 5 13 Peltier ON 1 2 3 4 Format p y Details 1 p Peltier 2 Delimiter 3 y Peltier ON 4 Line feed cod...

Страница 11: ...Format r p Details 1 r Capture mode 2 Delimiter 3 p Preview 4 Line feed code Response Normal OK Abnormal NG Note Configures capture as preview mode Table 5 13 Trigger Mode 1 2 3 4 Format r t Details...

Страница 12: ...C LVAL High 320 clk D LVAL Low 115 clk E LVAL neg edge to FVAL neg edge 112 clk F FVAL Low 230517 clk G LVAL pos edge to DVAL pos edge 0 clk H DVAL High 320 clk Description Value Units A FVAL High 22...

Страница 13: ...n 12 bits x 2 taps CL Port Bit Data 12bit Camera out 12 Bit A0 A 0 Tap1 A 11 0 A1 A 1 Tap2 B 11 0 A2 A 2 A3 A 3 A4 A 4 A5 A 5 A6 A 6 A7 A 7 B0 A 8 B1 A 9 B2 A 10 B3 A 11 B4 B 8 B5 B 9 B6 B 10 B7 B 11...

Страница 14: ...er board is recognized normally If you use our recommendations listed in table 2 2 the device names should be recognized as follows Table 6 1 Devices Recognized No Device 1 PIXCI EB1 PCI Express Camer...

Страница 15: ...dapter to the camera Figure 6 2 Icon of Tera Term After starting the software please choose the port correspondent with the name shown in device manager At the time this manual is made it is shown as...

Страница 16: ...ther operation but not necessary to be Table 6 2 Communication Protocol Item Settings New line Receive CR New line Transmit CR LF Local echo Check the box Figure 6 5 To Set up Terminal on Tera Term Af...

Страница 17: ...p the software you will see welcome message and license information If you have already registered please click OK directly If a warning or precaution concerning the license shows up you may not compl...

Страница 18: ...lay area First please set communication settings choose Configure to set Camera Link configuration bit tap and color Please refer to table 3 1 to confirm the Camera Link format Figure 6 10 Configure S...

Страница 19: ...of Camera Link in Timing Please refer to table 3 1 to confirm the Camera Link format Figure 6 12 Timing Settings The settings are finished now The image will be displayed either by clicking Live in Ca...

Отзывы: