Before You Start
IMPORTANT:
Observe all governing codes
and ordinances.
1. Proper installation is your responsibility. Ensure a
qualified/Jaquar technician installs your product.
2. An air vent and a service window must be
provided for product as basic requirement.
3. Electrical supply requirement: 220~240 volt (16 A)
Fluctuation may damage the product or its
component. Manufacturer recommends the use
of fluctuation free or stabilized power supply to
feed the product.
4. Water supply parameters like pH/hardness must
be maintained at below recommended level.
pH
7.5 – 8.5
TH
150 – 450 ppm.
Sanitizer
2- 4 ppm
Electrical Supply and safety devices.
a) The equipment must be connected to single phase
220 ~ 240 V and 50hz supply.
b) The equipment must be connected to the
equipotential/ differential switches of the room and
duly fastened to the specified clamp/terminals that
can be found on the product.
c) Connection to the power mains foresees installation
of a 30mA max. differential switch
(RCCB/ELCB/GFCI), with at least 3 mm contact
opening and suitable for a single phase supply.
d) Switches must be arranged near the device,
upstream of power boxes (only for product versions
equipped with power box).
e) The product’s supporting structure is made of metal,
therefore an efficient ground dispersal provision is
required, with regulations compliant sensitivity.
Earth Wire
The earth wire must be connected and fixed permanently
with a 3 mm dia. core conductor to the electrical system.