background image

Rail-Switch II User Guide

Overview

 

Page 4 

Connections

Input

The DMX512 input is attached via a 3-pin 

screw terminal. Please refer to the connections 

diagram.

Loop Through

A  passive  loop-through  connection  allows 

onward connection to other DMX512 devices. 

If this feature is not required then the signal 

must be terminated. The product contains an 

internal termination resistor. This is enabled by 

fitting a wire link between the screw terminals 

that  will  terminate  the  DMX  line  (Term  and 

DAT+).

In  theatre,  touring  and  architectural 

applications there are invariably some devices 

that do not provide a useful form of remote 

control. Rail-Switch II is an elegant solution 

to the automation of these devices.

Rail-Switch II is a DIN Rail mounted device 

that provides 6 mains voltage relays and is 

controlled  via  DMX512  &  RDM.  Each  relay 

can be switched independently. The product 

is powered via an external DC power supply 

unit. 

The product is configurable using RDM. This 

is particularly useful in enabling the start 

address of each relay to be set individually. 

Summary of Key Features

 

y

6 mains relays

 

y

Relays  rated  at  250V  AC,  8A  non-

inductive

 

y

DMX/RDM controlled

 

y

LED indication for data, power and each 

relay output

 

y

Simulated  RDM  sub-devices  for  start 

address programming

 

y

Preset mode eliminates need for DMX 

controller 

 

y

Data loss and test modes

 

y

DIN Rail or surface mount

Power 

Rail-Switch  II  is  be  powered  from  an 

external DC power supply (9-24 VDC). It is 

recommended that a ferrite core be fitted onto 

the DC power lines as close as possible to the 

Rail-Switch II. This protects the unit from any 

electrical spikes that appear on the DC line. 

Output

Six relay outputs are provided. It is 

recommended that the output wires are fitted 

with separate ferrite cores when driving a high 

current load.

Relays

NC

NO

C

The relays energise at a DMX value of 128.

Each relay has three connections; Common, 

Normally Open and Normally Closed. 

Common (C)

This  connection  is  always  used  and  is 

connected to either the open or closed pin 

depending on the state of the relay.

Normally Closed (NC)

This pin is connected to 

Common when the relay is 

not energised. 

Normally Open (NO)

This pin is not normally 

connected to the Common 

pin. The relay must be 

energised for a connection 

to be made.

Loading

Rail-Switch II uses electromechanical relays 

that  are  rated  for  8A  at  250  VAC  when 

switching  non-inductive  loads.  The  product 

can be used to drive inductive loads, or those 

with high inrush currents, so long as external 

surge protection is added. These devices stop 

the contacts from being damaged by arcing. 

Part code ‘Sequence-Filter’ is an external 

PTC filter suitable for this purpose.

The user must also ensure that external circuit 

protection such as circuit breakers or fuses 

are  connected  in  compliance  with  the  local 

wiring regulations.

Содержание Rail-Switch II

Страница 1: ...Artistic Licence Rail Switch II User Guide Rail Switch II Version 5 6 User Guide...

Страница 2: ...inside the outer case of this product Always disconnect from the power supply when not in use Any specific IP rating where appropriate is given in the instructions Unless otherwise stated this produc...

Страница 3: ...ck 2 Data Blue 3 Data Red Circuit Description DMX512 Input including Loop Through Type Non isolated Pin 1 Connects to Internal Logic Ground Relay Outputs Isolated volt free Internal Logic Ground Conne...

Страница 4: ...DMX controller y y Data loss and test modes y y DIN Rail or surface mount Power Rail Switch II is be powered from an external DC power supply 9 24 VDC It is recommended that a ferrite core be fitted...

Страница 5: ...Relays 1 6 right hand side Blue Relay is energised This windows based application provides a convenient means of accessing the Rail Switch II configuration menus DMX Workshop can also be used for prod...

Страница 6: ...for more than 2 5 seconds It can be selected to play one of the 8 presets or hold the last state If DMX returns the control is immediately returned Rail Switch II will also power up in this mode unti...

Страница 7: ...SD protection 12 kV y y Input voltage protection 80 V Data Connection y y 3 pin Screw Terminal DMX Input 1 no y y 4 pin Screw Terminal DMX Loop Term 1 no LED Indication y y Power DMX RDM Preset Test R...

Страница 8: ...ipment WEEE Artistic Licence is a member of a WEEE compliance scheme and will happily recycle any of our products that you at your expense return to us Safety Warning When Rail Switch II is used for h...