ARTEX PRODUCTS / ACR ELECTRONICS, INC.
DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL
ELT 1000 (P/N: A3-06-2749-1)
Y1-03-0259 Rev. U
Company Confidential
Page 32 of 62
B.
Troubleshooting
SYMPTOM
PROBABLE CAUSE
POSSIBLE SOLUTION
Remote switch LED always on
(steady)
Improper wiring
Verify wiring
Short circuit
Verify integrity of all crimp and
solder connections
ELT will not turn off
Turn ELT “OFF” using local switch – If ELT turns off:
Defective remote switch harness
reset circuit wiring
Check wiring continuity and repair
as necessary
Defective remote switch
Replace remote switch
If ELT does not turn “OFF” using local switch:
ELT defective
Remove battery pack to disable ELT
and return ELT to factory for
servicing
Flash Errors
Please Refer to Table 6 Self-test Error Codes
Table 7 ELT Troubleshooting Guide