Hardware Preparation and Installation
COMX-P4080-2G-ENP2 Installation and Use (6806800P63B
)
26
The following table summarized components that exhibit significant temperature raises and
their maximum allowable operating temperature. These components should be monitored in
order to assess thermal performance during customized thermal solution development.
Power Requirements
Table 2-2 Critical Temperature Spots
Component Identifier
Heat Dissipation Power (W)
Maximum Allowable Temperature
(
o
C)
CPU: P4080
20.5
CPU: 105 (Tj)
Memory SDRAM: 2GB
3
95 (Tc)
System Overheating
Colling Vents
Improper cooling can lead to system damage and an void the manufacturer's warranty. To
ensure proper cooling and undisturbed airflow through the system do into obstruct the
ventilation openings of the system. Make sure that the fresh air supply is not mixed with hot
exhaust from other devices.
Personal Injury
During operation, hot surfaces may be present on the heat sinks and the components of the
product.
To prevent injury from hot surface, do not touch any of the exposed components or heats-
inks on the product when handling. Use the handle and face plate, where applicable, or the
board edge when removing the product from the enclosure.
Содержание COMX-P4080-2G-ENP2
Страница 1: ...COMX P4080 2G ENP2 Installation and Use P N 6806800P63B August 2014 ...
Страница 6: ...COMX P4080 2G ENP2 Installation and Use 6806800P63B Contents 6 Contents Contents ...
Страница 8: ...COMX P4080 2G ENP2 Installation and Use 6806800P63B 8 List of Tables ...
Страница 10: ...COMX P4080 2G ENP2 Installation and Use 6806800P63B 10 List of Figures ...
Страница 18: ...COMX P4080 2G ENP2 Installation and Use 6806800P63B Safety Notes 18 ...
Страница 30: ...Hardware Preparation and Installation COMX P4080 2G ENP2 Installation and Use 6806800P63B 30 ...
Страница 68: ...BSP COMX P4080 2G ENP2 Installation and Use 6806800P63B 68 ...
Страница 69: ......