Chapter 2
COMX-P4080-2G-ENP2 Installation and Use (6806800P63B)
25
Hardware Preparation and Installation
2.1
Environmental and Power Requirements
You must make sure that following environmental requirements meet when board is operated
in your system configuration.
Environmental Requirements
The following table provides the environmental requirement details for the board:
Thermal Requirements
A standard passive heat sink or heat spreader can be provided by Emerson; 12 CFM system
airflow volume (at 71
o
C) is needed for the heat sink to keep sufficient cooling to the
COMXP4080-2G-ENP2. Contact your Emerson sales representative for current information on
the detailed thermal information of the COMX-P4080-2G-ENP2.
Operating temperatures refer to the temperature of air circulation around the board, but
not the component temperature.
Table 2-1 Environmental Requirements
Environmental Factor
Operating
Non-operating
Temperature
-40
o
C to +71
o
C
-50
o
C to +100
o
C
Humidity
to 100% RH
to 100% RH
Vibration Random (1hr/axis)
0.04g2/Hz, 15 to 2000Hz
(7.6GRMS)
Shock
30g/11mS(half sine)
Altitude
-60 to 4000 m ASL
Vibration Sine (10mins/axis)
Содержание COMX-P4080-2G-ENP2
Страница 1: ...COMX P4080 2G ENP2 Installation and Use P N 6806800P63B August 2014 ...
Страница 6: ...COMX P4080 2G ENP2 Installation and Use 6806800P63B Contents 6 Contents Contents ...
Страница 8: ...COMX P4080 2G ENP2 Installation and Use 6806800P63B 8 List of Tables ...
Страница 10: ...COMX P4080 2G ENP2 Installation and Use 6806800P63B 10 List of Figures ...
Страница 18: ...COMX P4080 2G ENP2 Installation and Use 6806800P63B Safety Notes 18 ...
Страница 30: ...Hardware Preparation and Installation COMX P4080 2G ENP2 Installation and Use 6806800P63B 30 ...
Страница 68: ...BSP COMX P4080 2G ENP2 Installation and Use 6806800P63B 68 ...
Страница 69: ......