6
CLEANING OF THE FILTERS
The dehumidifier is equipped with two filters:
1). Anti-dust filter
2). Activated carbon filter, in order to prevent the prolife-
ration of bacteria and bad smells (ex. kitchen smells)
The cleaning of the filters must be carried out periodical-
ly, at least every three months.
The operations to carry out are the following:
1. switch the dehumidifier off
2. withdraw the condensed water collecting tank
3. withdraw the filter by pulling it downwards (see fig. 1)
4. open gently the case that fastens the two filters paying
attention not to damage it.
5. clean the two filters with a vacuum cleaner (fig. 3) (the
activated carbon filter cannot be regenerated; the life of
this filter depends on the pollution degree of the room).
It is recommended to replace the activated carbon filter at
least every season
WARNINGS
IF THE DEHUMIDIFIER DOES NOT WORK:
IMPORTANT SAFETY RULES
figure 1
figure 2
figure 3
Read the instructions carefully before using the appliance.
The best results will be obtained by positioning the dehumidifier far from heat sources and keeping internal doors open
and external doors and windows well closed.
The dehumidifier does not operate at a temperature lower than 5°C and higher than 35°C and with a humidity level
lower than 30%.
WARNING: BEFORE CARRYING OUT ANY OPERATION
- ALWAYS DISCONNECT THE PLUG
- EMPTY THE CONDENSED WATER TANK
Never use the dehumidifier outdoor.
If you use it in the bathroom, be careful that water does not go inside the upper grille.
Install the appliance according to the international installation standards.
Be sure that no object interferes with the air flow.
The machine must not be connected to a multiple socket.
Do not pull the electric cable in order to remove the plug.
Never open the casing of the dehumidifier.
After having switched the machine off, always wait for at least one minute and a half before switching it on again.
After having been moved, the machine should stand still for at least one hour before switching it on again.
This dehumidifier is conceived exclusively for domestic use: any other use must be considered improper.
Do not use the machine in the event of malfunctions or if it appears damaged: in these situations, remove the plug and
ask for technical assistance.
Position the appliance in a place where the plug is easily accessible.
If the feed cable is damaged, it should be replaced by the manufacturer or by the technical assistance service or by a
person with similar qualification in order to avoid any risk.
The fuse supplied in the printed circuit board is a “T2A 250V” (for electronic model only).
If the dehumidifier does not work, before asking for technical assistance, check that:1-The plug is correctly connected
to the socket;
2-The general switch is on;
3-The red “tank full” light is off;
4-The “condensed water collecting" tank is correctly positioned;
5-The humidistat is well adjusted;
6-The air filter is not obstructed.
If the unit still does not function correctly, remove the plug and ask for technical assistance.
When you do not use the dehumidifier, it is recommen-
ded to wind the cable on the back and to place the plug
in the special conceived dap. To carry out this operation
it is necessary to wind the cable rightwards as shown in
the side pictures. The machine standard cable is 235 cm
long: if, in case of replacement, this length should be
altered, it will be impossible to wind the cable correctly.
1a
1b
2b