background image

WL 150 DIM / USER MANUAL / ENGLISH

8

03

2.6  SERVICE MENU

You can enter the service menu either from DMX channel 511 by holding down the but-

ton UP or from the channel 1 by holding down the button DOWN. The difference is only 

in the speed of the access to the desired function because from the channel 511 you will 

reach the beginning of the chained functions and from channel 1 the end of the chained 

functions.

BEGINNING (CH511 “hold down button UP”) - 7.c.1; 6.c.0; C.30……… C.01 – END (CH1 

“hold down button DOWN”)

Use of the equipment:

The luminaire WL-150 DIM is designed for 

the working and stage/studio lighting of the 

interiors.

Protection against electric shock:

The metal parts of the spotlight are conduc-

tive interconnected and the fixture is con-

nected by a terminal to the protective sys-

tem of the network.

The luminaire has the protection class of 

IP 40, which ensures sufficient protection 

against contact with live parts, but it does 

not protect your luminaire against ingress of 

water into the luminaire. The luminaire is not 

designed for use in outdoor or wet areas.

The connection and putting into operation of 

the fixture should be made only by qualified 

electrical technicians by course of the regu-

lation 50/78 Col.

Installation, assembly:

Installation, assembly:

The luminaire is equipped with yoke with 

screw holes for M10 screws. It is assumed 

that one of the luminaire holders will be at-

tached with screws M 10 to the luminaire 

yoke or that the luminaire will be attached 

by means of screws directly to the structure 

or to the wall.

The safety standard for the luminaires re-

quires additional fall protection, for this pur-

pose the luminaire is equipped on the sides 

with two holes. Through these holes a safe-

ty cable is run, which must be attached to a 

fixed structure.

The power supply is secured with a mov-

able lead cable - flexible cable 3 x 0,75 

mm2, length 1,5 m, equipped with a plug 

of a Schuko type. On the luminaire sides are 

locking nuts enabling setting of the fixture in 

the required working position.

Operation:

Because the fixture is at the same time a 

heat source, it is necessary to secure the 

heat dissipation (e.g. by due space in which 

the fixture is used).

OTHER INSTRUCTIONS

Содержание WL 150 DIM

Страница 1: ...WL 150 DIM USER MANUAL THEATRE AND STAGE LUMINAIRE ENGLISH VERSION 02 2017...

Страница 2: ......

Страница 3: ...to you the new working and stage studio floodlight WL 150 DIM of the company Art Lighting Production s r o Ltd Please read this operation manual carefully Non observance of the operation manual may c...

Страница 4: ...t we can adjust Color rendering index CRI 80 Max surface temperature 65 C Min distance from the surrounding objects 0 5 m Dimension 380 x 240 x 150 mm Enclosure protection class IP 40 Weight 4 6 kg Ma...

Страница 5: ...N 4 2 DEFAULT SETTINGS 5 2 1 DEFAULT DMX CHANNELS 5 2 2 WORKLIGHT FUNCTION 5 2 3 STROBO MODE 6 2 4 WORKLIGHT MODE 6 2 5 LIGHT INTENSITY BLOCKED DMX INPUT 7 2 6 SERVICE MENU 8 3 OTHER INSTRUCTIONS 8 4...

Страница 6: ...ER MANUAL ENGLISH 4 PRODUCT DESCRIPTION 01 1 Bracket for hanging lamps 2 Protecting light diffusion plate 3 DMX INPUT 4 DMX OUTPUT 5 Numeric display 6 Status light DMX LINK 7 Control buttons UP DOWN 3...

Страница 7: ...a period of 1 2 seconds when connected to the 230V electric power mains the luminaire does not re spond charging of the electronics and then gently starts up in a time of 1 second If you want to dim t...

Страница 8: ...tarts flashing 5 When pressing the button UP you will switch the 0 to 1 and the STROBO function 2 channel is activated The symbol has changed to 6 c 1 the second DMX channel STROBO is active 6 Back to...

Страница 9: ...ion should be used only when you do not want to use the Worklight func tion The input DMX signal is blocked after selection of this function 1 Using the buttons UP and DOWN set the DMX address 1 2 Wai...

Страница 10: ...inaire The luminaire is not designed for use in outdoor or wet areas The connection and putting into operation of the fixture should be made only by qualified electrical technicians by course of the r...

Страница 11: ...aining The fixture may be operated by trained per sons according to the regulation 50 78 Col When using the fixture the instructions of this Operation manual have to be observed Operating conditions I...

Страница 12: ...pment in a damp or wet environment Do not use the equipment in an environment with high operating tempera tures above 40 C Do not look at a short distance directly into the light if the equipment is s...

Страница 13: ......

Страница 14: ...ghting Production s r o Komensk ho 427 664 53 jezd u Brna esk republika Tel 420 544 224 312 info artlighting cz www artlighting cz 2017 Art Lighting Production s r o Graphic design v2atelier com WL 15...

Отзывы: