Instant/Delay Mode

Your system will normally arm in the Delay Mode when leaving the

premise.  This will delay arming, allowing time to exit.  When entering,

the alarm will be delayed allowing time to disarm the system.  The

audible warning device will sound during the entrance delay remind-

ing you to disarm the system.  The Instant Mode is primarily used in

residences.  If this is desired, the key sequence is as follows:

If a zone(s) are to be bypassed in conjunction with entering the Instant

mode or the group bypassing is desired simply enter the zone

number(s) or the [* 1] prior to the [*] key in the sequence above.

Arming/Disarming Reports By User

The Arming and Disarming by user code identifies the user who

disarms and arms the system.  This is accomplished by assigning an

individual user code to each of the eight possible users.  The primary

user code is always reported as user one.  Seven additional secondary

user codes report as user 1-7.  Select secondary codes as shown in

“Changing Code(s) From the Keypad” Section.

Testing the Communicator

Your installer should instruct you on how to test , and how often to test

the communicator portion of your system.  Various central monitoring

stations have different procedures for testing  the communicator. Your

installer is familiar with this procedure.

Содержание KP600F

Страница 1: ...KP600F L LED LCD KEYPADS Owner s Manual Use with AV6500 SP850 Control panels P N 64812823 A PDF 10 23 97 IT IS IMPORTANT FOR YOUR SAFETY TO TEST YOUR SYSTEM AND IT S COMPONENTS REGULARLY...

Страница 2: ...ant Delay Mode 9 Arming Disarming Reports By User 9 Testing the Communicator 9 Testing Your System 10 Smoke Detector Reset 10 Setting Chime Mode 11 Fault Condition 11 Duress Ambush 12 Emergency Alarm...

Страница 3: ...delays silent alarm duress power failure communication failure fire trouble and others Consult with your installer and make sure you understand which ones are programmed and how they are used The mat...

Страница 4: ...s to other users or service persons for whom you want to grant entry Obviously they can also be used in any other way that you desire These codes can only be changed using the primary user code Arming...

Страница 5: ...system Trouble or Fault Condition exists The LCD DISPLAY indicates system status in English with READY ARMED BYPASSED VIOLATED TROUBLE and ALARM conditions all being displayed System information such...

Страница 6: ...or Fault Condition exists Red ZONE Lights These lights indicate different conditions depending on the status of the system When the system is Disarmed lights that are ON indicate violated zones When t...

Страница 7: ...SIDENCE Arming Your System If the READY light is lit on the LCD keypad or all zone lights OFF on the LED all zones may be armed by entering your User Code using the key sequence below When the READY l...

Страница 8: ...eypad s Status light and all active zone lights will be lit Zone 3 is now deactivated If the window is closed and opened again an alarm condition will not result as this burglary zone will be bypassed...

Страница 9: ...zone number s or the 1 prior to the key in the sequence above Arming Disarming Reports By User The Arming and Disarming by user code identifies the user who disarms and arms the system This is accomp...

Страница 10: ...to return to Normal During the test each door contact motion detector etc should be violated which will cause a short blast from the siren output The Entry Exit delays are shortened to 4 seconds duri...

Страница 11: ...D keypad indicates this Fault condition with the STATUS LED flashing with the audible tone To identify the nature of the Fault Condition press and HOLD the ENTER key This will also silence the audible...

Страница 12: ...e in Trouble The LCD will scroll each of the zone s and the LED keypad will light the appropriate zone LED IT IS IMPORTANT FOR YOUR SAFETY THAT YOU HAVE YOUR INSTALLER CORRECT ANY FAULTS AS SOON AS PO...

Страница 13: ...re marked with a circle square diamond or triangle Consult your installer dealer as to which one s of these are used if any and which combination initiates which alarm The special symbols above and be...

Страница 14: ...This example shows user 2 being changed or added to the system as 9886 User code number 2 is now programmed as 9886 into your system Additional users may be changed or added to the system using the s...

Страница 15: ...is taken by the answering fax equipment will be required before the panel will answer To Use Call the premises telephone number Allow the phone to ring the proper number of times Your installer will s...

Страница 16: ...should have a rope ladder that reaches the ground 5 Draw a sketch of the escape route and familiarize everyone in the home with it 6 Select a meeting place outside where everyone is to report 7 Practi...

Страница 17: ...be responsible for expenses or labor incurred in removing and reinstalling its products from the retail purchaser s location If examined equipment is found not to be defective or is not for some other...

Страница 18: ...LIMITED WARRANTY OR IN ANY OTHER MANNER WARRANT OR GUARANTEE THAT THIS PRODUCT WILL PREVENT PERSONAL INJURY OR PROPERTY LOSS PURCHASER SHOULD TAKE ALL REASONABLE AND AVAILABLE PRECAUTIONS IN PROTECTI...

Отзывы: