Transfer 

has to  be pressed to  export the  values stored 

in memory as text format to PC by USB port. 

6.7.4 Delete by Group No. 

 

 

Delete  by  No. 

:The  range  of  deleted  groups  is 

displayed. The digit figure keys have to be pressed to input 

the number.  

ETR  

has to be pressed to delete the selected groups. 

ESC  

has to be pressed to cancel the operation. 

 

Note:  1.If the present  group exceeds the actual range, 

the actual groups among them will be deleted! 

2.  The  instrument  may  not  be  powered  off  while 

deleting  data.  This  could  lead  to  unpredicted 

consequences! 

 

6.7.5 Delete all Data 

By  pressing 

Delete  All 

,  all  data  in  memory  will  be 

deleted. 

 

6.7.6 Deletion Confirmation 

 

 

The 

key  or  the 

key  has  to  be  pressed  to 

move the cursor to 

YES 

and 

key deletion. 

The 

key  or  the 

key  has  to  be  pressed  to 

move the cursor to 

NO 

and 

ETR 

has to be pressed 

to cancel deletion. 

ESC   

has  to  be  pressed  to  cancel  deletion,  no  matter 

where the cursor is located. 

 

6.8    Browsing Memory Data Groups 

  

 

 

 

 

 

 

 

 

 

 

The 

or 

key  has to  be pressed to see previous 

or next page. 

ESC  

has to be pressed to exit browsing. 

ETR 

has  to  be  pressed  and  then 

or 

to 

move  the  cursor  to  the  desired  line  you  want  to  see  the 

details  from. 

ETR 

has  to  be  pressed  to  see  details  of 

that group. 

 

 

The 

or 

key has to be pressed to browse details 

including average value, test set and each single value. 

ESC  

has to be pressed to return to previous display. 

 

6.9 System Set 

 

At  the  main  display  interface, 

MENU 

key  has  to  be 

pressed to enter the main menu. 

 

 

or 

 

key  has to be  pressed to  move the cursor 

to 

System  Set   

Menu. 

ETR 

has  to  be  pressed  to 

enter 

System Set  

Menu. 

 

 

Auto Save: Off 
Auto Print: Off 
Auto Delete: Off 
Auto Trans: Off 
Key sound: On 
Warn.  Sound:  On 
LCD Brightness 
Time Date Set 

 

 

or 

 

key  has to be  pressed to  move the cursor 

to the desired item.         
By pressing, the setting can be directly modified or into the 

corresponding screen. 

ESC 

has to be pressed to exit.  

Auto  Save 

,   

Auto  Delete 

Auto  Trans. 

,   

Key 

Sound 

Warn. Sound 

can be switched on or off now. 

If 

Auto Save 

is set to <On>, according to 3

б

 rule, gross 

errors  can  be  cancelled  automatically  after  having 

measured  preset  average  times  or  pressing  end  in 

advance.  If  there  is  any  data  cancelled,  it  needs 

supplemental measurement to reach the preset times. 

If 

Auto  Trans. 

is  set  to  <On>,  the  value  of  the  present 

group  can  be  exported  by  USB  after  measuring  and 

displaying the average value. 

If 

Key  Sound 

is  set  to  <On>,  the  buzzer  will  make  a 

short hoot while a key is being pressed each time. 

If 

Warn.  Sound 

is  set  to  <On>,  if  the  measured  value 

exceeds  the  tolerance  limit,  the  preset  average  times  or 

deleting  data  are  reached,  the  buzzer  will  make  a  long 

hoot. 

 

No.001  12/03   652HL 

No.002  12/03   587HL 

No.003  12/03   820HL 

No.004  12/03   693HL 

No.005  12/03   783HL 

No.006  12/03   782HL 

No.007  12/03   579HL 

No.008  12/03   687HL 

 

No.002  12/03   785HL 

No.003  12/03   516HL 

No.004  12/03   789HL 

No.005  12/03   570HL 

No.006  12/03   852HL 

No.007  12/03   523HL 

No.008  12/03   796HL 

No.001  12/03   514HL

 

Содержание ARW-HMR

Страница 1: ...al Setting 6 5 4 Hardness Scale Setting 6 5 5 Tolerance Limit Setting 6 5 6 Hardness б b Setting 6 6 Print Set 6 7 Memory Management 6 7 1 View from No 1 Group View from Ending Group 6 7 2 View from Selected No Group 6 7 3 Data Transfer 6 7 4 Delete by Group No 6 7 5 Delete all Data 6 7 6 Deletion Confirmation 6 8 Browsing Memory Data Groups 6 9 System Reset 6 9 1 LCD Brightness Setting 6 9 2 Date...

Страница 2: ... 3 Standard test block 1 4 Cleaning brush I 1 5 Small support ring 1 6 Alkaline battery 4 AA size 7 Manual 1 8 Instrument case 1 9 Optio nal Config uration 11 Cleaning brush II 1 For use with G type impact device 12 Other type of impact devices and support rings Refer to Table 3 and Table 4 in the appendix 13 DataPro for HL200 software 1 14 Communication cable 1 1 4 Working Conditions Working Temp...

Страница 3: ...suring range HLD 170 960 HLD Measuring direction 0 360 Hardness Scale HL HB HRB HRC HRA HV HS Display dot matrix LCD 128 x 64 dots Data memory max 500 groups Power supply 3V 2AA size Alkaline batteries Continuous working period about 50 hours with backlight off Communication interface USB1 1 4 Preparation Testing 4 1 Preparation and Inspection before Testing 4 1 1 Preparation of Sample Surface Pre...

Страница 4: ...on should pass the axis of the impact device Each measurement area of the sample usually needs 3 to 5 times of testing operations The result data dispersion should not be more than the mean value 15 HL The distance between any two impact points or from the centre of any impact point to the edge of the sample should conform to the regulation of Table 4 1 If an accurate conversion from the Leeb hard...

Страница 5: ...esting Operation at the Main Display Testing operation can be carried out under this interface After each impact operation the current measured value can be displayed Impact times count plus one the buzzer will alert a long howl if the measured value is not within the tolerance limit As soon as the preset impact times are reached the buzzer will alert a long howl After two seconds the buzzer will ...

Страница 6: ...s to be pressed to move the cursor to the desired impact direction ETR has to be pressed to confirm ESC has to be pressed to cancel 6 5 2 Average Times Setting Average times can be modified within the range of 1 to 32 The 0 9 key has to be pressed to input the number value The cursor will shift right around automatically when inputting the number ETR has to be pressed to confirm ESC has to be pres...

Страница 7: ...xceeds the measurement range the user will be reminded by the Tester to reset 2 If the bottom limit is larger than the upper limit they will be exchanged automatically 6 5 6 Hardness бb Setting ETR has to be pressed to switch between Hard and бb Note Only D and DC type of impact device have got the function of бb measurement So Hard is the only selection if the impact device is not D or DC type 6 ...

Страница 8: ...including average value test set and each single value ESC has to be pressed to return to previous display 6 9 System Set At the main display interface MENU key has to be pressed to enter the main menu or key has to be pressed to move the cursor to System Set Menu ETR has to be pressed to enter System Set Menu Auto Save Off Auto Print Off Auto Delete Off Auto Trans Off Key sound On Warn Sound On L...

Страница 9: ...after measuring 5 times or key has to be pressed to input the nominal value ETR has to be pressed to confirm ESC has to be pressed to cancel this operation Range of adjustment 15HL 6 12 EL Background Light By means of the background light it is convenient to work in dark conditions key has to be pressed to switch on or off the background light at any time if necessary after the instrument is power...

Страница 10: ...e It has to be taken out and repeated for 5 times At last the impact body and the support ring have to be installed again The impact body has to be released after use Any lubricant is absolutely prohibited inside the impact device 8 2 Normal Maintenance Program If the standard Rockwell hardness block is used to test and if all the error is bigger than 2 HRC the ball top of the impact device or the...

Страница 11: ...9 8 68 2 20 7 68 2 22 6 70 2 HV 80 898 80 935 100 941 82 1009 Stainless steel HRB 46 5 101 7 HB 85 655 HV 85 802 Grey cast iron HRC HB 93 334 92 326 HV Nodular cast iron HRC HB 131 387 127 364 HV Cast aluminium alloys HB 19 164 23 210 32 168 HRB 23 8 84 6 22 7 85 0 23 8 85 5 BRASS copper zinc alloys HB 40 173 HRB 13 5 95 3 BRONZE copper alum tin alloys HB 60 290 Wrought copper alloys HB 45 315 Tab...

Страница 12: ... 4µm 6 3µm 1 6µm Min weight of sample Measure directly Need support firmly Need coupling tightly 5kg 2 5kg 0 05 2kg 5kg 2 5kg 0 05 2kg 1 5kg 0 5 1 5kg 0 02 0 5kg 15kg 5 15kg 0 5 5kg 5kg 2 5kg 0 05 2kg Min Thickness of sample Coupling tightly Min layer thickness for surface hardening 5mm 0 8mm 5mm 0 8mm 1mm 0 2mm 10mm 1 2mm 5mm 0 8mm Size of tip indentation Hardness 300HV Indentation diameter Depth...

Страница 13: ...25 50 For testing cylindrical outside R25 R50 4 HZ11 13 For testing cylindrical inside R11 R13 5 HZ12 5 17 For testing cylindrical inside R12 5 R17 6 HZ16 5 30 For testing cylindrical inside R16 5 R30 7 K10 15 For testing spherical outside surface SR10 SR15 8 K14 5 30 For testing spherical outside surface SR14 5 SR30 9 HK11 13 For testing spherical inside surface SR11 SR13 10 HK12 5 17 For testing...

Отзывы: