ARROWELD ARW-HMR Скачать руководство пользователя страница 7

 
 
 
 

Instruction Manual 

ARW-HMR  

 

 

AS, 02.12.2010 

HMR GB 

Page 7 of 13 

ARROWELD ITALIA Spa 

Via M. Pasubio, 137   

36010 Zanè (VI)-(Italia)  
Tel +39 0445 492313  

Fax +39 0445 491365 

E-mail:[email protected]   

 

Steel,  Cr-Ni  Steel,  Cr-Mo  Steel,  Cr-Ni-Mo  Steel,  Cr-Mn-Si 

Steel, Super Strength Steel and Stainless Steel. 

 

The 

or 

key  has  to  be  pressed  to  move  the 

cursor to the material desired to preset. 

ETR  

has to be pressed to confirm. 

ESC  

has to be pressed to cancel. 

 

6.5.4 Hardness Scale Setting 

 

 

The 

or 

key  has  to  be  pressed  to  move  the 

cursor to the hardness scale desired to preset. 

ETR  

has to be pressed to confirm. 

ESC  

has to be pressed to cancel. 

 

Note: 1. Only the valid hardness scale for the present 

selected impact device and material are displayed.  

An invalid hardness scale will not be displayed. 

2. Please select material first and then select hardness 

scale. 

3.  Presetting  the  hardness  scale,  HL  is  automatically 

recovered after material presetting has been changed. 

 

6.5.5 Tolerance Limit Setting 

 

 

The 

~     

key  has  to  be  pressed  to  input  the 

number  value.  The  cursor  will  shift  right  around 

automatically when inputting. 

ETR  

has to be pressed to confirm. 

ESC  

has to be pressed to cancel. 

Note:  1.  If  the  preset  value  exceeds  the  measurement 

range, the user will be reminded by the Tester to reset. 

2. If the bottom limit is larger than the upper limit, they 

will be exchanged automatically. 

 

6.5.6 Hardness / 

б

b Setting 

 

 

ETR   

has  to  be  pressed  to  switch  between  Hard  and 

б

b. 

Note:  Only  D  and  DC  type  of  impact  device  have  got 

the function of 

б

b measurement. So, “Hard” is the only 

selection if the impact device is not D or DC type. 

 

6.6    Print Set 

At  the  main  display  interface, 

MENU 

key  has  to  be 

pressed  to  enter  the  main  menu.  Printing  function  is  not 

available at Hardness Tester HMR. 

 

6.7    Memory Management 

 

At the  main display interface, the 

MENU 

key  has to be 

pressed to enter the main menu. 

 

The 

or 

key  has  to  be  pressed  to  move  the 

cursor  to 

Memory  Manager

ETR   

key  has  to  be 

pressed in 

Memory Manager

menu. If there is no data in 

memory,  <No  Data!>  will  be  displayed.  Then  it  has  to  be 

returned. 

 

 

The 

or 

key  has  to  be  pressed  to  move  the 

cursor to the desired function. 

ETR  

has to be pressed to confirm. 

 

6.7.1 View from No.1 Group/ View from Ending Group 

 

View From No.1 

: values in the memory from the first            

                                  group are displayed. 

View From End 

:  values in the memory from the 

                                  ending group are displayed. 

 

6.7.2 View from Selected No. Group 

 

 

The  digit  figure  keys  have  to  be  pressed  to  input  the 

number.  

ETR   

has  to  be  pressed  to  start  displaying  memory 

data from the selected beginning group.  

ESC  

has to be pressed to cancel. 

 

6.7.3 Data Transfer 

Содержание ARW-HMR

Страница 1: ...al Setting 6 5 4 Hardness Scale Setting 6 5 5 Tolerance Limit Setting 6 5 6 Hardness б b Setting 6 6 Print Set 6 7 Memory Management 6 7 1 View from No 1 Group View from Ending Group 6 7 2 View from Selected No Group 6 7 3 Data Transfer 6 7 4 Delete by Group No 6 7 5 Delete all Data 6 7 6 Deletion Confirmation 6 8 Browsing Memory Data Groups 6 9 System Reset 6 9 1 LCD Brightness Setting 6 9 2 Date...

Страница 2: ... 3 Standard test block 1 4 Cleaning brush I 1 5 Small support ring 1 6 Alkaline battery 4 AA size 7 Manual 1 8 Instrument case 1 9 Optio nal Config uration 11 Cleaning brush II 1 For use with G type impact device 12 Other type of impact devices and support rings Refer to Table 3 and Table 4 in the appendix 13 DataPro for HL200 software 1 14 Communication cable 1 1 4 Working Conditions Working Temp...

Страница 3: ...suring range HLD 170 960 HLD Measuring direction 0 360 Hardness Scale HL HB HRB HRC HRA HV HS Display dot matrix LCD 128 x 64 dots Data memory max 500 groups Power supply 3V 2AA size Alkaline batteries Continuous working period about 50 hours with backlight off Communication interface USB1 1 4 Preparation Testing 4 1 Preparation and Inspection before Testing 4 1 1 Preparation of Sample Surface Pre...

Страница 4: ...on should pass the axis of the impact device Each measurement area of the sample usually needs 3 to 5 times of testing operations The result data dispersion should not be more than the mean value 15 HL The distance between any two impact points or from the centre of any impact point to the edge of the sample should conform to the regulation of Table 4 1 If an accurate conversion from the Leeb hard...

Страница 5: ...esting Operation at the Main Display Testing operation can be carried out under this interface After each impact operation the current measured value can be displayed Impact times count plus one the buzzer will alert a long howl if the measured value is not within the tolerance limit As soon as the preset impact times are reached the buzzer will alert a long howl After two seconds the buzzer will ...

Страница 6: ...s to be pressed to move the cursor to the desired impact direction ETR has to be pressed to confirm ESC has to be pressed to cancel 6 5 2 Average Times Setting Average times can be modified within the range of 1 to 32 The 0 9 key has to be pressed to input the number value The cursor will shift right around automatically when inputting the number ETR has to be pressed to confirm ESC has to be pres...

Страница 7: ...xceeds the measurement range the user will be reminded by the Tester to reset 2 If the bottom limit is larger than the upper limit they will be exchanged automatically 6 5 6 Hardness бb Setting ETR has to be pressed to switch between Hard and бb Note Only D and DC type of impact device have got the function of бb measurement So Hard is the only selection if the impact device is not D or DC type 6 ...

Страница 8: ...including average value test set and each single value ESC has to be pressed to return to previous display 6 9 System Set At the main display interface MENU key has to be pressed to enter the main menu or key has to be pressed to move the cursor to System Set Menu ETR has to be pressed to enter System Set Menu Auto Save Off Auto Print Off Auto Delete Off Auto Trans Off Key sound On Warn Sound On L...

Страница 9: ...after measuring 5 times or key has to be pressed to input the nominal value ETR has to be pressed to confirm ESC has to be pressed to cancel this operation Range of adjustment 15HL 6 12 EL Background Light By means of the background light it is convenient to work in dark conditions key has to be pressed to switch on or off the background light at any time if necessary after the instrument is power...

Страница 10: ...e It has to be taken out and repeated for 5 times At last the impact body and the support ring have to be installed again The impact body has to be released after use Any lubricant is absolutely prohibited inside the impact device 8 2 Normal Maintenance Program If the standard Rockwell hardness block is used to test and if all the error is bigger than 2 HRC the ball top of the impact device or the...

Страница 11: ...9 8 68 2 20 7 68 2 22 6 70 2 HV 80 898 80 935 100 941 82 1009 Stainless steel HRB 46 5 101 7 HB 85 655 HV 85 802 Grey cast iron HRC HB 93 334 92 326 HV Nodular cast iron HRC HB 131 387 127 364 HV Cast aluminium alloys HB 19 164 23 210 32 168 HRB 23 8 84 6 22 7 85 0 23 8 85 5 BRASS copper zinc alloys HB 40 173 HRB 13 5 95 3 BRONZE copper alum tin alloys HB 60 290 Wrought copper alloys HB 45 315 Tab...

Страница 12: ... 4µm 6 3µm 1 6µm Min weight of sample Measure directly Need support firmly Need coupling tightly 5kg 2 5kg 0 05 2kg 5kg 2 5kg 0 05 2kg 1 5kg 0 5 1 5kg 0 02 0 5kg 15kg 5 15kg 0 5 5kg 5kg 2 5kg 0 05 2kg Min Thickness of sample Coupling tightly Min layer thickness for surface hardening 5mm 0 8mm 5mm 0 8mm 1mm 0 2mm 10mm 1 2mm 5mm 0 8mm Size of tip indentation Hardness 300HV Indentation diameter Depth...

Страница 13: ...25 50 For testing cylindrical outside R25 R50 4 HZ11 13 For testing cylindrical inside R11 R13 5 HZ12 5 17 For testing cylindrical inside R12 5 R17 6 HZ16 5 30 For testing cylindrical inside R16 5 R30 7 K10 15 For testing spherical outside surface SR10 SR15 8 K14 5 30 For testing spherical outside surface SR14 5 SR30 9 HK11 13 For testing spherical inside surface SR11 SR13 10 HK12 5 17 For testing...

Отзывы: