ARROWELD ARW-HMR Скачать руководство пользователя страница 2

 
 
 
 

Instruction Manual 

ARW-HMR  

 

 

AS, 02.12.2010 

HMR GB 

Page 2 of 13 

ARROWELD ITALIA Spa 

Via M. Pasubio, 137   

36010 Zanè (VI)-(Italia)  
Tel +39 0445 492313  

Fax +39 0445 491365 

E-mail:[email protected]   

 

 

Upper and lower limit can be preset. It will alarm 
automatically if the result value is exceeding the 

limit. 

 

Battery  information:  rest  capacity  of  battery  is 
indicated. 

 

Software calibration function 

 

Software to connect with PC and USB port 

 

Compact metal case, suitable for use under poor 
working conditions 

 

Continuous  working  period  of  not  less  than  50 
hours with two Alkaline batteries (AA size);  

 

Auto Power Off to save energy 

 

Dimensions:   132 mm x 76.2 mm 

 

Weight:   345 g 

 

1.2    Main Application & Testing Range 

1.2.1 Main Application 

 

 

Die cavity of molds

 

 

Bearings and other parts

 

 

Failure  analysis  of  pressure  vessels,  steam 
generators and other equipment

 

 

Heavy work piece

 

 

Testing the surface of a small hollow space

 

 

Material  identification  in  the  range  of  metallic 

materials

 

 

1.2.2 Testing Range 

Please refer to Table 1 and Table 2 in the APPENDIX. 

 

1.3    Configuration 

Table 1-1 

 

No. 

Item 

Qua
ntity 

Remarks 

Stan 
dard 
Config
uration 

Main body 

1  

 

D type impact 
device 

1  

With cable 

Standard test 
block 

1  

 

Cleaning brush 
(I) 

 

Small support 
ring 

 

Alkaline battery 

AA size 

Manual 

 

Instrument case 

 

 

 

 

Optio 
nal 
Config
uration 

11 

Cleaning brush 
(II) 

For use with G 
type impact 
device 

12 

Other type of 
impact devices 
and support 
rings 

 

Refer to Table 3 
and Table 4 in 
the appendix. 

13 

DataPro for 
HL200 software 

 

14 

Communication 
cable 

 

 

1.4 Working Conditions 

Working Temperature:   0°C up to +40°C 

Storage Temperature:   -30°C up to +60°C 

Relative humidity:   

≤ 90%

 

Vibrations,  strong  magnetic  field,  corrosive  medium  and 

heavy dust should be avoided in the surroundings.  

 

2.      Structure Feature & Testing Principle 

2.1    Structure Feature 

2.1.1 Hardness Tester Appearance 

 

 

 

 

 

 

 

 

 

 

 

 

1. Main body             2.Impact device 

 

2.1.2 Parts of the Main body 

 

 

 

 

 

 

 

 

 

 

 

 

 

1    Socket of USB 

2    Aluminium case 

3    Belt hole 

4    Battery cover 

5    Keypad 

6    LCD Display 

7    Socket of Impact Device 

8    Aluminium case, (backside) 

9    Label (backside) 

 

2.1.3  D Type of Impact Device 

 

Mi Tec h

9

7

8

0

1

2

4

5

6

2

1

HL-200 HARDNESS GAUGE

MTL

HD

TIME

DEL

SAVE

MENU

DIR

AVG

ESC

ETR

3

2

4

MENU

DIR

ESC

AVG

0

1

2

MiTec h

ETR

TIME

4

5

MTL

7

8

DEL

6

HD

9

SAVE

5

HL-200 HARDNESS GAUGE

7

6

8

7.          Set Impact Di rection

MiTech Inc. Ltd

www.mitech-ndt.com

8.          Avera ge Result

1. Plug  In Imp act Prob e Cable

2.          Power On/Off

3.          Backlight On/Off

4.          Se t Hardn ess Scale

5.          Select Material

6.          Set Average Times

HL-200 HARDNESS GUAGE

OPERATING  GUIDE

SN:

9

Содержание ARW-HMR

Страница 1: ...al Setting 6 5 4 Hardness Scale Setting 6 5 5 Tolerance Limit Setting 6 5 6 Hardness б b Setting 6 6 Print Set 6 7 Memory Management 6 7 1 View from No 1 Group View from Ending Group 6 7 2 View from Selected No Group 6 7 3 Data Transfer 6 7 4 Delete by Group No 6 7 5 Delete all Data 6 7 6 Deletion Confirmation 6 8 Browsing Memory Data Groups 6 9 System Reset 6 9 1 LCD Brightness Setting 6 9 2 Date...

Страница 2: ... 3 Standard test block 1 4 Cleaning brush I 1 5 Small support ring 1 6 Alkaline battery 4 AA size 7 Manual 1 8 Instrument case 1 9 Optio nal Config uration 11 Cleaning brush II 1 For use with G type impact device 12 Other type of impact devices and support rings Refer to Table 3 and Table 4 in the appendix 13 DataPro for HL200 software 1 14 Communication cable 1 1 4 Working Conditions Working Temp...

Страница 3: ...suring range HLD 170 960 HLD Measuring direction 0 360 Hardness Scale HL HB HRB HRC HRA HV HS Display dot matrix LCD 128 x 64 dots Data memory max 500 groups Power supply 3V 2AA size Alkaline batteries Continuous working period about 50 hours with backlight off Communication interface USB1 1 4 Preparation Testing 4 1 Preparation and Inspection before Testing 4 1 1 Preparation of Sample Surface Pre...

Страница 4: ...on should pass the axis of the impact device Each measurement area of the sample usually needs 3 to 5 times of testing operations The result data dispersion should not be more than the mean value 15 HL The distance between any two impact points or from the centre of any impact point to the edge of the sample should conform to the regulation of Table 4 1 If an accurate conversion from the Leeb hard...

Страница 5: ...esting Operation at the Main Display Testing operation can be carried out under this interface After each impact operation the current measured value can be displayed Impact times count plus one the buzzer will alert a long howl if the measured value is not within the tolerance limit As soon as the preset impact times are reached the buzzer will alert a long howl After two seconds the buzzer will ...

Страница 6: ...s to be pressed to move the cursor to the desired impact direction ETR has to be pressed to confirm ESC has to be pressed to cancel 6 5 2 Average Times Setting Average times can be modified within the range of 1 to 32 The 0 9 key has to be pressed to input the number value The cursor will shift right around automatically when inputting the number ETR has to be pressed to confirm ESC has to be pres...

Страница 7: ...xceeds the measurement range the user will be reminded by the Tester to reset 2 If the bottom limit is larger than the upper limit they will be exchanged automatically 6 5 6 Hardness бb Setting ETR has to be pressed to switch between Hard and бb Note Only D and DC type of impact device have got the function of бb measurement So Hard is the only selection if the impact device is not D or DC type 6 ...

Страница 8: ...including average value test set and each single value ESC has to be pressed to return to previous display 6 9 System Set At the main display interface MENU key has to be pressed to enter the main menu or key has to be pressed to move the cursor to System Set Menu ETR has to be pressed to enter System Set Menu Auto Save Off Auto Print Off Auto Delete Off Auto Trans Off Key sound On Warn Sound On L...

Страница 9: ...after measuring 5 times or key has to be pressed to input the nominal value ETR has to be pressed to confirm ESC has to be pressed to cancel this operation Range of adjustment 15HL 6 12 EL Background Light By means of the background light it is convenient to work in dark conditions key has to be pressed to switch on or off the background light at any time if necessary after the instrument is power...

Страница 10: ...e It has to be taken out and repeated for 5 times At last the impact body and the support ring have to be installed again The impact body has to be released after use Any lubricant is absolutely prohibited inside the impact device 8 2 Normal Maintenance Program If the standard Rockwell hardness block is used to test and if all the error is bigger than 2 HRC the ball top of the impact device or the...

Страница 11: ...9 8 68 2 20 7 68 2 22 6 70 2 HV 80 898 80 935 100 941 82 1009 Stainless steel HRB 46 5 101 7 HB 85 655 HV 85 802 Grey cast iron HRC HB 93 334 92 326 HV Nodular cast iron HRC HB 131 387 127 364 HV Cast aluminium alloys HB 19 164 23 210 32 168 HRB 23 8 84 6 22 7 85 0 23 8 85 5 BRASS copper zinc alloys HB 40 173 HRB 13 5 95 3 BRONZE copper alum tin alloys HB 60 290 Wrought copper alloys HB 45 315 Tab...

Страница 12: ... 4µm 6 3µm 1 6µm Min weight of sample Measure directly Need support firmly Need coupling tightly 5kg 2 5kg 0 05 2kg 5kg 2 5kg 0 05 2kg 1 5kg 0 5 1 5kg 0 02 0 5kg 15kg 5 15kg 0 5 5kg 5kg 2 5kg 0 05 2kg Min Thickness of sample Coupling tightly Min layer thickness for surface hardening 5mm 0 8mm 5mm 0 8mm 1mm 0 2mm 10mm 1 2mm 5mm 0 8mm Size of tip indentation Hardness 300HV Indentation diameter Depth...

Страница 13: ...25 50 For testing cylindrical outside R25 R50 4 HZ11 13 For testing cylindrical inside R11 R13 5 HZ12 5 17 For testing cylindrical inside R12 5 R17 6 HZ16 5 30 For testing cylindrical inside R16 5 R30 7 K10 15 For testing spherical outside surface SR10 SR15 8 K14 5 30 For testing spherical outside surface SR14 5 SR30 9 HK11 13 For testing spherical inside surface SR11 SR13 10 HK12 5 17 For testing...