12
Crimped Rib
Uncrimped Rib
Whenever a crimped rib and an uncrimped rib
meet, the crimped rib should be placed UNDER
the uncrimped rib if possible. See next page.
Use the diagram to the right when attaching Wall Panels.
• Secure the top row to Top Frames
• Secure the middle row to Wall Channels
• Secure the lower row to Floor Frames
• Secure the circled holes to the Panel next to it
FASTEN TO TOP FRAMES
FASTEN TO FLOOR FRAMES
FASTEN TO WALL CHANNELS
7822
IMPORTANT:
When installing the Wall
Panels over a Truss, you will need to ‘roll’
the Panels as shown to be able to attach the
next Panel at the overlap. When securing the
Panel to the building with Small Screws, do
not insert Screws in the row of holes closest
to the last rib of the Panel. Next, roll the Panel
back slightly and attach the next Panel at the
overlap with a Bolt and Nut in the center hole.
Once this is done, continue securing the Panel
to the building.
LEAVE LAST ROW OF HOLES EMPTY
UNTIL NEXT PANEL IS IN PLACE
Step 7 - Install all Wall Panels.
12J
13
13J
Install ALL Wall Panels:
A)
Working one side at a time, lift the Panels into place and secure with three Small Screws in the top
of the Panel, three Small Screws in the middle of the Panel, and three Small Screws in the bottom
of the Panel. Roll the Panel back as shown on the previous page and overlap the rib with the rib of
the next Panel.
B)
Secure the Panels with a Bolt and Nut thru the center hole at the overlap (see below). Next, fi nish
securing the Panels to the building with Small Screws as shown in the diagram on the previous
page.
C)
Continue until all Wall Panels have been installed.
Use washers on all fasteners
used on painted parts.
Place Bolt thru center hole where Panels overlap.
Continue until ALL Wall
Panels have been installed.
You will need the following parts for this step:
7822 Wall Panel