background image

DVi25S Direct Vent Gas-Fired Fireplace Insert Room Heater

®

MANTEL

  12"
MAX.

 12"
MIN.

14"

TOP OF
  UNIT

Diagram B - DVi25S  Clearances

F.  FIREBOX ENTRY

Remove the glass by pulling out [2] Glass Retainer latches.  See Figure 1.  Lift the Glass Door Assembly up and
remove from the bottom retainer.  See Figure 2.     

Place Glass in a safe place until installation is complete.             

Figure 1 - Glass Retainer Latches

Figure 2 - Glass Removal

9-98

6                                                                              29855A

WARNING!

FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THESE DIAGRAMS OR FAILURE

TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN

PROPERTY DAMAGE AND/OR PERSONAL INJURY.

E.  CLEARANCES TO UNIT

Diagram B shows the minimum vertical and corresponding maximum horizontal dimensions of mantels or other com-
bustible projections above the gas fireplace of 12 inches.

When finishing the fireplace 

NEVER OBSTRUCT OR MODIFY THE AIR INLET/OUTLET OPENINGS IN ANY MANNER.

While a hearth extension may be desirable for aesthetic reasons, it is not required for gas wall heaters per ANSI or
CAN/CGA testing standards.

Provide adequate accessibility clearances for servicing and proper operation.

Содержание DVi25S

Страница 1: ...or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch Do not use any pho...

Страница 2: ...OCATED OUT OF TRAF FIC AND AWAY FROM FURNITURE AND DRAPERIES 3 CHILDREN AND ADULTS SHOULD BE ALERT ED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITI...

Страница 3: ...round must be purchased separately 6 Front Face Kit must be purchased separately Optional components include 1 Remote Control 2 Surround Bottom 3 Rectangular Front Face Kit 4 Arched Front Face Kit 5 B...

Страница 4: ...er Flex 923GK 3 Direct Vent Chimney Liner Termination Kit Dura Vent product 710 3 Chimney Liner Flex 35 Dura Vent product 980 Vertical Termination Cap with Wind Halo Dura Vent product 991 High Wind Te...

Страница 5: ...ram A DVi25S Dimensions D HIGH ALTITUDE INSTALLATION For U S installation this appliance has been test ed and approved for elevations from 0 2000 feet When installing this appliance at an elevation ab...

Страница 6: ...CCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY DAMAGE AND OR PERSONAL INJURY E CLEARANCES TO UNIT Diagram B shows the minim...

Страница 7: ...starter collar bracket Note Fireplace chimney systems must be cleaned thoroughly and inspected before installation of the appliance If any portion of the chimney system shows signs of structural or m...

Страница 8: ...eled collar on the termination See Figure 5 Figures 6 and 7 show typical installations of the appli ance Termination Cap Adaptor Inlet Air Collar Exhaust Collar WARNING The exhaust pipe must only be c...

Страница 9: ...ed to the left side The gas supply line should be installed and connected to the shut off valve by a qualified service person in accor dance with all prevailing building codes A 3 8 flare adapter not...

Страница 10: ...round against the face of the unit aligning the holes in the upper and lower right and left corners and secure the surround to the unit with the attachment screws See Figure 13 If optional surround bo...

Страница 11: ...es no larger than 1 2 diameter b Lay the Rock Wool pieces on the top of the Burner so that the flame can touch the Rock Wool and create the glowing ember look Be sure not to pack the Rock Wool against...

Страница 12: ...and the Male end to the Black wire on the Fan Control For the BF30 35 go to Step 5 5 Place Switch Extension Bracket under the Clip located on the Bottom Pan and slide the Bracket back until it is flus...

Страница 13: ...The Valve Access Door located at the base of the Bay Front Face is opened by lifting up on the Door Handle and then rotating downward This will expose the Gas Valve Pilot Controls Burner Controls and...

Страница 14: ...to the lower right side of the appliance to allow the Blower to be plugged in J WIRING WARNING DO NOT connect 110 120 VAC to the Gas Control Valve or Control Wiring System of this unit TO TEST JUNCTI...

Страница 15: ...as leaks This may be done with a soap and water solution or a gas detector 4 Make sure the glass is sealed and in its proper position Never operate this heater with the glass removed or not sealed 5 F...

Страница 16: ...at set to lowest setting 3 Open control access panel 4 Find the pilot The pilot is inside the combustion chamber next to the main burner 5 If the gas control knob is at the OFF position go to step 7 I...

Страница 17: ...this moisture will disappear and within 15 30 minutes the flames should become yellow CAUTION During the initial purging and subsequent lightings NEVER allow the gas valve control knob to remain depre...

Страница 18: ...ol System and any Gas Control which has been under water CLEANING THE GLASS It is recommended to wear gloves while handling or removing the glass DO NOT REMOVE THE GLASS WHEN HOT To gain entry to the...

Страница 19: ...lve to ON Turn switch to ON Check wiring connections at the valve and switch Set thermostat to a lower temperature Check wiring connections and wiring diagram Not heated up enough takes about a minute...

Страница 20: ...478 Pilot Assembly Natural Gas 29479 Pilot Assembly L P 3b 17245 SS Flex Gas Line 4b 19641 Brass Fitting 1 2 3 8 5b 15697 ON OFF Valve 6b 16564 Valve Connector 7b 29850 Valve Bracket 8b 12387 10 32 x...

Страница 21: ...7097 Fan Assembly Not Shown 9 20613 Variable Spd Control Not Shown 10 27234 Thermostat Assembly Not Shown 11 30440 Surround Side RH 32 30441 Surround Side RH 38 11 12 13 14 15 16 17 4 1 2 7 3 6 18 19...

Страница 22: ...Top 28235 Door Frame Trim Bottom 28743 Access Tab ITEM PART DESCRIPTION B 29675 Bay Front Face Assembly 29674 Top Face 29672 Upper Front Face 29671 Front Face 29673 Lower Front Face 29679 Lower Acces...

Страница 23: ...and temporary repairs do not qualify for a service call fee and will not be covered The replacement of consumer replaceable items and installation of upgraded component parts do not qualify for a ser...

Страница 24: ...98 24 29855 Rev B Attention INSTALLER Please return these Operating Installation Instructions to the Consumer Aladdin Hearth Products 401 N Wynne Colville WA 99114 A Division of Hearth Technologies I...

Отзывы: