DVi25S Direct Vent Gas-Fired Fireplace Insert Room Heater
H. GOLD TRIM CLEANING
All prints and smudges must be wiped clean from the
gold trim prior to initial burn. If this is not done, these
prints will be cured into the gold finish and set for the
life of the heater. To keep the finish looking its best,
gently wipe with a soft cloth. If desired, use a non-
abrasive cleaner such as soap and water. Never use
any solvent, thinner, or abrasive cleaner since these
will damage the finish.
WARNING!
DO NOT operate appliance with the Panel(s) removed, cracked or broken. Replacement of
the Panel(s) should be done by a Licensed or Qualified Service Person.
WARNING!
This appliance is equipped with a Three-
prong (grounding) Plug for your protec-
tion against shock hazards and should
be plugged directly into a properly
grounded Three-prong Receptacle. Do
not cut or remove the Grounding Prong
from this plug.
9-98
13 29855A
Valve Access for the Bay Front Face.
The Valve Access Door, located at the base of the
Bay Front Face, is opened by lifting up on the Door
Handle and then rotating downward. This will
expose the Gas Valve, Pilot Controls, Burner
Controls, and Fan Controls. See Figure 7BF.
AIR
SLOT
Figure 5BF
Placing Lava Rock Into Bay
Figure 6BF
Placing Bay into Slots
Figure 7BF - Valve Access Door
Figure 4BF
Extension Knob
I. BLOWER
This appliance has a factory installed Blower,
Junction Box, variable speed Rheostat Control
Switch and Temperature Sensor Switch for the
Blower. The Blower, temperature sensor switch and
junction box are located behind the lower grille. To
provide the 110-120 VAC, 60 HZ are needed at the
junction Box. Simply plug the 3-prong grounded
cord into a 3-prong grounded 110-120 VAC, 60 HZ
wall outlet. This cord exits the unit at the lower right
hand front surround corner.
The Temperature Sensor Switch will automatically
turn the Blower ON when the unit warms up. To
install or service the Blower, this appliance must be
removed from the fireplace. Remove the five sheet
metal screws holding the Blower cover in place and
slide the Blower cover out. Reverse to install the
Blower.