background image

Instruction Manual of PR5534-01 Model Controller

          

2010-12-01                   N0

VER1.1 

 

                             

  - 

safety during using, please read the following items carefully before using

 

1.  The end user should carry on the load installation strictly according to the wiring 

diagram and parameters. 

2.  The ground wiring should be connected to the normal-running supply circuits, so as for 

the steaming. 

3.  The end user should use power supply cables in 3 x 3mm

2

  or wider cable diameter. 

According to the National standards (GB). The socket should be of 30A or above 

according to the National standards (GB). 

4.  The end user should install air-break or leakage switch of 30A or above according to 

the National standards (GB). 

5.  Please check strictly the wire of input water pipe, steaming pipe, power box and control 

box. After confirming every part is OK, then you can start the shower device.

specially, 

make sure all operation should keep inside water.

 

6.  The steaming device and power box cannot be installed in the sauna shower; it should 

be installed according to the instruction on the shell. 

7.  The inner hole of steam input pipe should be above 15mm; installing valve in the 

output pipe is forbidden. 

8.  Please do not install the equipments of bad quality that manufactured by illegal 

factories to the steaming device; Disassembling, changing the fixed inner wiring or 

connect some wiring to the power box are forbidden. 

9.  The water quality should comply with the local water standards. 

10.  During installation, connect drainage pipe to the steaming device and lead the water 

our-side of the shower. It’s better to install a filter to the input so as to prolong the 

lifetime. 

11.  In the hard-water area, please wash the steaming device and remove the dirt 

periodically. The special water level sensor is probe (indicated by label on the 

steaming device surface). Normally, the user should check every 3 months and do the 

washing according to the practical condition. Suggesting washing methods: dilute 

5~10gs of citric acid with 1.4 liters of water, disassemble the connection pipes of 

Содержание 6100

Страница 1: ...of this controller and stop heating for 30 minutes before touching it 3 Without the clear approval from the controller manufacturer or its authorized units any change or alternation to this controller might bring various inconveniences to the users when in use Attention 1 Please read this operating instruction manual thoroughly so as to allow you to master the correct use of this controller 2 Afte...

Страница 2: ...herwise it will not work or even burn out the controller 4 When installing this controller carefully check if the load parameters are consistent with the parameters required by this controller otherwise it will not work or even burn out the controller 5 If it is halted accidentally please close and restart II Brief introduction 1 General description of the functions MODEL FUNCTIONS PR5534_01 1 LCD...

Страница 3: ...ty to the noise limit of the radio 20 dB µ V 8 Telephone ringing level AC45V AC55V 9 Step down transformer meeting the requirements of 1500V high voltage test as specified by IEC standard 4 LCD shows the following information 5 Characteristics of the remote controller 1 7 color lamp DC12V 5W 2 Loudspeaker 8Ω 15W 3 Ozone generator AC12V Max6W 4 Steam generator AC220V 3000W 6 Schematic Diagram of co...

Страница 4: ...plays LOCK then all the keys will be locked press any key to unlock the keys LOCK on LCD disappears 3 ON OFF 3 1 Press to turn on the controller 7 color lamp are turned on press again to turn off the controller all functions will be turned off 4 7 color lamp When the system is on press or to move the cursor to Light press to turn on the lamp 7 color changes automatically light icon on LCD blinks p...

Страница 5: ...or stops heating Inner temperature Default temperature 1 The steam generator reheats 5 1 2 When run out of the work time steam function stopped automatically 5 2 Press again to turn off the steam function steam icon stops blink 5 3 Temperature setting 5 3 1 When the steam function is on press continually till temperature on LCD blinks then press to increase the temperature press to decrease the te...

Страница 6: ...length of one step 100KHz press this button over 2 seconds the system searches the radio stations of larger frequencies automatically the digital phase locked loop will lock the FM station automatically and the liquid crystal shows the frequency of this station when it reaches to the limit of 87 5MHz press this button again and the frequency jumps to 108 0MHz 6 5 When the FM radio is on and the cu...

Страница 7: ...ursor when the cursor select Music then press continually till LCD displays MP3 then press to turn on the MP3 function press again the turn off the MP3 function 8 2 When the Mp3 function is on press continually till LCD display MP3 then press to play the next song press to play the previous song 8 3 When the MP3 function is on press continually till LCD display VOL then press to increase the volum...

Страница 8: ...n the cleaning function is on the water level cannot achieve the checking value whine 60seconds liquid crystal shows E2 and sound Du Du and the cleaning function stops 2 3 E3 Malfunction of Overtime water level checking When the water level checking malfunction E2 alarms for over 2 minutes the power is still on and the malfunction is not cleared the liquid crystal shows E3 and sound Du Du By then ...

Страница 9: ...ing device and power box cannot be installed in the sauna shower it should be installed according to the instruction on the shell 7 The inner hole of steam input pipe should be above 15mm installing valve in the output pipe is forbidden 8 Please do not install the equipments of bad quality that manufactured by illegal factories to the steaming device Disassembling changing the fixed inner wiring o...

Страница 10: ...5 Do not try to repair of the modifier parts of the controller and the high voltage might cause danger All the maintenance and repairing should be carried our by qualified personal For any consequences caused by wrong operation the user should bear the responsibility VI Declaration 1 Any maintenance or repairing should be handled by qualified maintenance personal authorized by the manufacturer or ...

Отзывы: