Keys

 

 

Function confirm

 

  

Left

 

 

Confirm

 

 

Right

 

 

ON/OFF

 

III. Operation of Control Panel

 

When any function button works, there is a sound of di… di… .

 

Lock   

2.1 

Without any operation with the control panel for 3 minutes

the keys will be 

locked and LCD displays “LOCK”

then all the keys will be locked; press any key 

to unlock the keys,

 

“LOCK” on LCD disappears.

   

  ON/OFF 

3.1 

Press 

 to turn on the controller, 7 color lamp are turned on, press again to 

turn off the controller, all functions will be turned off.

 

7 color lamp 

When the system is on

press ”

”  or  “

”    to move the cursor to “Light”, press 

” to turn on the lamp

7 color changes automatically

, light icon on LCD blinks; 

press “

” again to choose the colors; press“

” continually for 2 seconds to turn 

off the lamp, light icon on LCD stops blink. 

Steam sauna 

Содержание 6100

Страница 1: ...of this controller and stop heating for 30 minutes before touching it 3 Without the clear approval from the controller manufacturer or its authorized units any change or alternation to this controller might bring various inconveniences to the users when in use Attention 1 Please read this operating instruction manual thoroughly so as to allow you to master the correct use of this controller 2 Afte...

Страница 2: ...herwise it will not work or even burn out the controller 4 When installing this controller carefully check if the load parameters are consistent with the parameters required by this controller otherwise it will not work or even burn out the controller 5 If it is halted accidentally please close and restart II Brief introduction 1 General description of the functions MODEL FUNCTIONS PR5534_01 1 LCD...

Страница 3: ...ty to the noise limit of the radio 20 dB µ V 8 Telephone ringing level AC45V AC55V 9 Step down transformer meeting the requirements of 1500V high voltage test as specified by IEC standard 4 LCD shows the following information 5 Characteristics of the remote controller 1 7 color lamp DC12V 5W 2 Loudspeaker 8Ω 15W 3 Ozone generator AC12V Max6W 4 Steam generator AC220V 3000W 6 Schematic Diagram of co...

Страница 4: ...plays LOCK then all the keys will be locked press any key to unlock the keys LOCK on LCD disappears 3 ON OFF 3 1 Press to turn on the controller 7 color lamp are turned on press again to turn off the controller all functions will be turned off 4 7 color lamp When the system is on press or to move the cursor to Light press to turn on the lamp 7 color changes automatically light icon on LCD blinks p...

Страница 5: ...or stops heating Inner temperature Default temperature 1 The steam generator reheats 5 1 2 When run out of the work time steam function stopped automatically 5 2 Press again to turn off the steam function steam icon stops blink 5 3 Temperature setting 5 3 1 When the steam function is on press continually till temperature on LCD blinks then press to increase the temperature press to decrease the te...

Страница 6: ...length of one step 100KHz press this button over 2 seconds the system searches the radio stations of larger frequencies automatically the digital phase locked loop will lock the FM station automatically and the liquid crystal shows the frequency of this station when it reaches to the limit of 87 5MHz press this button again and the frequency jumps to 108 0MHz 6 5 When the FM radio is on and the cu...

Страница 7: ...ursor when the cursor select Music then press continually till LCD displays MP3 then press to turn on the MP3 function press again the turn off the MP3 function 8 2 When the Mp3 function is on press continually till LCD display MP3 then press to play the next song press to play the previous song 8 3 When the MP3 function is on press continually till LCD display VOL then press to increase the volum...

Страница 8: ...n the cleaning function is on the water level cannot achieve the checking value whine 60seconds liquid crystal shows E2 and sound Du Du and the cleaning function stops 2 3 E3 Malfunction of Overtime water level checking When the water level checking malfunction E2 alarms for over 2 minutes the power is still on and the malfunction is not cleared the liquid crystal shows E3 and sound Du Du By then ...

Страница 9: ...ing device and power box cannot be installed in the sauna shower it should be installed according to the instruction on the shell 7 The inner hole of steam input pipe should be above 15mm installing valve in the output pipe is forbidden 8 Please do not install the equipments of bad quality that manufactured by illegal factories to the steaming device Disassembling changing the fixed inner wiring o...

Страница 10: ...5 Do not try to repair of the modifier parts of the controller and the high voltage might cause danger All the maintenance and repairing should be carried our by qualified personal For any consequences caused by wrong operation the user should bear the responsibility VI Declaration 1 Any maintenance or repairing should be handled by qualified maintenance personal authorized by the manufacturer or ...

Отзывы: