Maintenance
WARNING!
Risk of electric shock!
Follow the safety Precautions.
Caution!
Do not attempt to oil or lubricate any parts in the machine. All
bearings are pre-lubricated and will be damaged if any
lubricant is added.
Exchanging the Out-feed Belt
a)
Set the diameter selector (a) to
34 mm
(max.).
b)
Open the inspection cover.
c)
Raise the feed mechanism (b) and the out-feed belt (c).
d)
Remove the old out-feed belt and exchange it for a new one.
e)
Replace the feed mechanism and the out-feed belt.
f)
Close the inspection cover.
g)
Reset the diameter selector to the desired position.
Cleaning
Caution!
Only use cleaning materials and implements which do not
scratch
Clean the machine
daily
to prevent from accumulation of dirt,
since this may cause too many coins to be rejected.
Wipe the coin detector with a soft brush or a soft cloth.
Use a vacuum cleaner to remove dust from the rotating disc.
Cleaning the coin track
Clean the coin track at regular intervals to ensure high counting
performance.
a)
Open the inspection cover.
b)
Raise the feed mechanism (b) to get to the coin track.
c)
Raise the thickness guide block (a).
>>>
a
c
b