GPM - 312-A

   

COUNTER     

INSTRUCTION MANUAL

100 Taskant street, B.R. Puram, Peelamedu, 

Coimbatore - 641004.Phone no : 0422 4218101

GREEN MICROELECTRONICS INDIA PVT. LTD.

 Manufacturer

Thank you very much for purchasing  this GREEN product GPM - 312-A.
Please read the instruction manual carefully for the full usage of this product

The counter has passed various quality tests before despatch. Please check however,
at the time of arrival, its model code and its appearance and ensure that all the contents 
are provided and there are no faults, damage etc, to the counter. Please also ensure that  
the model code ,which is labeled on the counter, is identical to the one you ordered.

Note :

1. Our company shall not be liable for any damages, as described below, caused to both 
    any users and third parties
 a) Damages caused by the result of operation of the product.
 b) Damages caused by any defects in the product which are unpredictable for us. 

2. The content in this manual are subject to change without any notice. If you have any 
suggestion on the matter, Please do not hesitate to contact us.  

GREEN

COMPONENTS FOR AUTOMATION

Introduction 

Precaution for safe use

(1)   Use and store the Counter within the specified ambient temperature and humidity
        ranges.

(2)   Do not use the product in location subject to vibrations or shocks. Using the product
       in such location over a long period may result in damage due to stress.

(3)   Do not use the product in locations subject to dust, corrosive gases, or direct sunlight

(4)  Separate the input signal devices, input signal cables and the product from the source 
       of noise or high - tension cables producing noise.

  - mail : greenmicroelectronics@airtel

.in

e

mail

   -   www.greenelectronics.in

(5)  The supplied power voltage and load must be within the rated and specified ranges.

(6)  Do not use where the water or oil splatter on the counter

(7)  Install a switch or circuit breaker that allows the operator to immediately turn off the
      power    

.

Six digits, 0.4 Inch seven segment LED  

3  Keys  &  Displays

                                                   Two relay, 1 c/o 

10 A  @ 230 VAC  

 (Resistive load)

 / 30 VDC

5 VA

Manual, Remote                                                                    

999 999  Counts

  Up

SPECIFICATIONS  

Front panel

Rear panel - Connection diagram

External dimensions 

Panel cutout dimensions

All dimensions are in mm

75

10

90

45

24V AC, 50HZ

170  grams

96 x 48 x 75

Ambient humidity                                                                                35 to 85 % RH                                                                   

   10 million operation 

  100.000 operation 

  -10 to 55 c 

  -25 to 65 c  

+ / -10% from the rated voltage                                                                               

In the pack                                                                                          counter, side clamp and instruction manual                                                               

Wiring diagram

COUNTER

COUNTER

PNP Proximity unit 

 30 Hz  

Memory Retension                                                                    

Input Pulse and  Relay                                                                      

Three (Main Count, Batch Count, Time) 

1

9

2

3

4

10

5

11

12

13

6

7

8

14

15

24 VDC

MAIN RLY 

NO    C            NC

SENSOR 

RESET

O / P

16

 PNP

PROXIMITY

LED

85 - 265 V AC, 50HZ

SUPPLY

              E             P             N

BC RLY
   

NO    

C               

NC

TM

   Display                                                                 

User programming                                                

   Output                                                                     

Relay contact rating           

Power consumption                                                

    Reset 

    Range                                                                   

Count direction                                                     

  Dimensions

48

96

Supply voltage                                                                    

Weight                                                                    

Dimension            

( L  x W x D) 

Mechanical life of relay                                                                    

Electrical life of relay                                                

Ambient temperature                                                              

Storage temperature                                                         

Operating voltage range                                                                    

GPM - 312A

GREEN

SET

      INPUT PULSE

RELAY

GPM - 312A

GREEN

SET

     INPUT PULSE

RELAY

   Input                                                                                                       

   Pulse frequency                                                                                    

   Special feature                                                                                     

   Indications                                                                                              

   Set points                                                                                              

Отзывы: