All dimensions shown in mm unless otherwise stated.

i

i

Any cut lengths should be de-burred and touched up with touch-up paint supplied prior to installation.
For more information or further assistance, please contact us.

Installation Guide for

SWAGED & FLUSHJOINT

DOWNPIPE  FIXING

We advise that you ensure the fi xing background is in good condition and will support the downpipe and that there are 

suffi  cient clips/brackets in place to secure the load.
When fi tting Colonnade downpipes, start from the outlet and work towards the gully.  Make sure you have the right 

combination of off sets/bends/branches and pipe to complete the installation.
Maximum fi xing centres is 2 metres – using correct stainless-steel fi xings and plugs for the substrate being fi tted to.

Ensure vertical alignment between drain 
and gutter outlet.  

Adjust the off set to suit the projection.  

Place the off set in position from the outlet 
and fi x the fi rst pipe into place, thus 
holding the off set in position. 

Sealant can be applied to the inside of the 
pipe socket prior to installation. Swaged and 
fl ushjoint downpipes should have sealant 
applied to the socket prior to installation.  
Cast Collared can be sealed after fi tment.  
When fi tting fl ushjoint downpipe, sealant can 
also be applied to the inside of the clip to 
assist in supporting the pipe. 

A pipe clip should be fi xed directly beneath 

the pipe socket.  

3

2

1

Additional pipe clips should be fi tted at 2m 

maximum intervals.  

Carry on installing pipes in this fashion 

until reaching the drain. Clips to be fi xed 
with plastic wall plugs and stainless steel 
screws of a size suitable for the substrate.

A shoe, drain adaptor or off set may be 

required to terminate the pipe work into the 
gully

As per local building regulations, if a 

shoe is not installed access pipes should 
be fi tted and positioned to give suitable 
rodding access as required.

4

5

6

2000mm