Santiago
English
05060120 00 11/05/2011
33
X
Disassemble the shoulders (if present).
X
Position the cabinets side by side
X
Remove the backrests to have access to the holes of the risers
X
Join the risers and the brackets, using the screws supplied
X
Reassemble the backrests.
X
Make sure the alignment pins are inserted in their provided seats.
X
Sliding doors (Rif. 27): when you've finished combining the frames, apply the
stainless steel shet supplied between the frames in the inner part of the cabinet.
Channel combination Kit
12.Electrical connection (Pag. 8) -
specialized technician
-
It is the Client's responsibility to arrange the electrical power supply line up to the point
of connection to the cabinet. Sizing of the electrical power supply line must be
performed in accordance to the power absorbed by the cabinet (see Technical Data).
X
Remove all metallic objects worn: rings, watches, bracelets, earrings, etc.
X
Consult the wiring diagrams before performing the connection.
X
Check that power supply voltage is the one reported on the rating plate.
X
Instruct the operator on the position of the switch so that it may be timely reached in
case of an EMERGENCY.
X
To ensure normal operation, the maximum variation of the voltage must range
b/- 6% of the nominal value.
X
Check that the power supply line has wires with an appropriate diameter, that it is
protected against overcurrents, and that the leakages to ground are in compliance to
the norms in force.
X
If the electrical power supply is interrupted, check that all the electrical devices of the
store can restart without triggering the intervention of the overload protections; if
Ref.
Code
Description
1
04711065 Screw TCEI M8x120
2
04480112 Washer D8,5x24
3
04230600 Nut M8
4
02940045 Alignment pin D3x40
5
02940652 Alignment pin D4x80
6
02047000 Alignment pin D10
7
04230003 Nut M4 (flanged, knurled stainless steel)
FOR SWING DOORS
8
04706025 Screw TSP M4 x 8mm cross-head
9
04525108 Lead screw fastpoint
FOR THE SLIDING DOORS
10 04703014 Screw AF TSP 3,5x19
BEFORE ANY OPERATION REMOVE VOLTAGE TO THE SYSTEM!
The electrical
system must have a grounding connection!
X
The systems must be set up in accordance to the norms that regulate
manufacture, installation, use, and maintenance foreseen by the norms in force
in the country where the cabinet is installed.
X
ARNEG Spa rejects any responsibility toward the user and third parties for
damages caused by breakdowns or malfunctions of the systems arranged
upstream of the cabinet and for damages to the cabinet that stem from causes
directly ascribable to an electrical system malfunction.
X
The cabinet must be protected upstream with an automatic, omnipolar
magneto-thermal switch having adequate characteristics and which will serve
as the main line disconnecting switch.