Athos 2
English
05060087 02 13/05/2010
17
11) Net display surface
12) Type of refrigerant fluid with which the plant operates
13) Mass of refrigerant gas with which each single plant is loaded
14) Environment climatic categories and reference temperature
15) Protection class against humidity
16) Job order number with which the cabinet has been manufactured
17) Order number with which the cabinet has been produced
18) Cabinet year of production
In case of technical assistance, in order to identify the cabinet communicate the following:
- the product name (Fig. 2 - 2); the serial number (Fig. 2 - 4); the job order number (Fig. 2 - 18);
5. Transport (Fig. 3)
The cabinets are supplied on a wooden support fixed to the base for movement with forklift trucks.
Always position the forks at the point specified on the wooden support to avoid the risk of
overturning
. Use a manual or electrical forklift truck that is suitable to moving the cabinet in question.
It must have a nominal capacity of at least 1,000 kg.
6. Receipt and first cleaning
On receiving the cabinet:
- Make sure that the packaging is integral and that there are no signs of evident damage;
- Carefully remove the packaging so as not to damage the cabinet;
- Check the integrity of the cabinet components;
- Call the supplier immediately if damage is detected;
- Use neutral products for a first cleaning of the cabinet. Dry with a soft cloth, do not use abrasive
substances or metal sponges.
- DO NOT use alcohol to clean the methacrylate (Plexiglas) parts
When disposing of the packaging consider that it consists of:
Wood - Polyester - Polythene - PVC - Cardboard.
The suitability of the materials stated above is declared for the purpose and effects of the EEC 94/62
Directive.
7. Installation and environmental conditions (Fig. 3)
When installing respect the following:
- Do not position the cabinet:
- in environments where explosive gas substances are present;
- in open areas and therefore exposed to atmospheric agents;
- near to heat sources (direct sun light, heating plants, incandescent lamps);
- near to air currents (doors, windows, air conditioning plants etc) that exceed the speed of
0.2m/sec
.
- Remove the wooden supports on the base (used for transport) and mount the adjustable feet (Rif. 2)
positioning them so that the cabinet is horizontally positioned and with the aid of a leveller (Rif. 1)
check its position. Make sure that all feet are on the floor.
- If the cabinet is moved repeat the levelling control.
- Before connecting the cabinet to the power line make sure that the data on the plate corresponds to
the features of the electric plant to which it must be connected.
- For the cabinet to function correctly, the temperature and the environment relative humidity must
respect the parameters envisioned by the
EN-ISO 23953 - 1/2
standard that foresees Climatic
Category 3 (
+25°C; U.R. 60%)
.
ATTENZIONE!: Install a maximum of 3 cabinets on the same electric and refrigerating power
line (1 2 Slave).
N.B.All of these operations must be carried out by specialised technical staff
8. Electric connection (Fig. 10 - Fig. 11 - Fig. 12)
- The cabinet must be protected upstream by an automatic omnipolar magnet circuit breaker switch
with adequate features and that will function also as the line master switch.
- Instruct the operator regarding the position of the switch so that it can be reached quickly in case of
an EMERGENCY.
- The electric plant must be earthed.
- First check that the supply voltage is that indicated on the data plate
.
- In order to guarantee correct functioning, it is necessary that the maximum voltage varies b/