Athos 2
English
16
05060087 02 13/05/2010
1. Introduction - Purpose of the manual/Application field
This instructions manual refers to the
Athos 2
refrigerated cabinets line.
The information that follows provides indications relating to:
Use of the cabinet, technical features, installation and assembly, information for the operator in charge
of use, maintenance interventions.
This manual is to be considered part of the cabinet and must be preserved for its entire duration.
The manufacturer cannot be held responsible for:
Improper use of the cabinet, installation not carried out in compliance with the standards indicated,
electric power supply faults, lack of envisioned maintenance, unauthorised modifications and
interventions, use of non original spare parts, failure to comply with the instructions.
N.B.Electric appliances may be dangerous for ones health.
Regulations and existing laws in force must be respected during installation and use.
This manual must be read by anyone using this cabinet.
2. Presentation - Declared use (Fig. 1)
The
Athos 2
refrigerated cabinets line, with a remote condensation unit, is suitable for displaying deli
meats and milk products.
3. Norms and certifications
All the refrigeration unit models described in the usage manual for the
Athos 2
series meet the
essential requirements for safety, health, and protection required by the following European directives
and laws:
- Machines Directive 2006/42 EC;
harmonised standards applied: EN ISO 14121:2007; EN ISO 12100-1:2005; EN ISO 12100-2:2003
- Electromagnetic Compatibility Directive 2004/108/EC;
harmonised standards applied: EN 61000-3-2:2006; EN 61000-3-12:2005; EN 55014-1:2006;
EN 55014-2:1997;
- Low Voltage Directive 2006/95/EC;
harmonised standards applied: EN 60335-1:2008; EN 60335-2-89 :2002/A2:2007
European Regulation
EC-1935/2004
on materials and articles intended to come into contact with food
- standards applied: EN 1672-2
They are excluded from the field of application of Directive
EEC 97/23 (PED)
on the basis
of that
specified by Article 3 paragraph 3 of the Directive.
A copy of the declaration of product conformity can be requested by filling in the form available
at the internet address:
http://
www.arneg.it/conformity
The performance of these refrigerated units has been determined by means of tests carried out in
accordance with standard
UNI EN ISO 23953-2: 2006
in the environmental conditions corresponding
to climate class 3 (25 °C , 60% Rel. Humidity)
Environmental climatic classes according to UNI EN ISO 23953 - 2
4. Identification - Data plate (Fig. 2)
Inside the cabinet a plate with all the characteristc data is present:
1) Name and address of the manufacturer
2) Name and length of the cabinet
3) Cabinet code number
4) Cabinet serial number
5) Supply voltage
6) Power frequency
7) Input current
8) Electric power absorbed during the refrigeration phase (fans+hot cables)
9) Electric power input during the defrost phase (Hot fan eva
defrosting resistance)
10) Lighting power (where foreseen)
Climatic class
Temp. dry bulb
Relative humidity
Dew point
1
16?
80%
12?
2
22?
65%
15?
3
25?
60%
17?
4
30?
55%
20?
5
40?
40%
24?
6
27?
70%
21?