background image

www.armytek.com

between them for 3 seconds:

l

 

2xCR123A 3V (Li batteries, min voltage 0V) 

– the 

flashlight blinks once. 

l

1x18650 Li-Ion 3.7V (Li-Ion rechargeable battery, min 

voltage 2.8V) 

– the flashlight blinks twice. 

l

 

2xR123 Li-Ion 3.7V (Li-Ion rechargeable battery, min 
voltage 5.6V) 

– the flashlight blinks 3 times.

l

 

1x18650 LiFePO4 3.2V (LiFePO4 rechargeable battery, 
min voltage 2.5V) 

- the flashlight blinks 4 times.

Selection confirmation:  tighten/loosen the head within 1 
second while the required choice is activated or the flashlight 
pauses after it. The flashlight saves your selection and changes 
the Setting Menu to the standard operation mode. If you do not 
make your choice within 1 minute, your flashlight exits from the 
Setting Menu into the standard operation mode without saving 
your selection. 

The value by default:  2xCR123A 3

В

 (Li 

batteries).

Item

 6. 

Stabilization Type Selection

Entry: when you confirm your choice by tightening/loosening the 
head at blinking for 6 times, which indicates the Item 6 of the 
menu, the flashlight shows through indication the accessible 
alternatives of the LED current stabilization types pausing 
between them for 3 seconds:

l

 

FULL. 

The maximum full stabilization at all battery types 

and operation modes - the flashlight blinks once.

l

 

SEMI. 

The simple semi-stabilization as for the buck driver - 

the flashlight blinks twice.

l

 

STEP. 

The stepped stabilization - the flashlight blinks 3 

times.

Selection confirmation: tighten/loosen the head within 1 second 
while the required choice is activated or the flashlight pauses 
after it. The flashlight saves your selection and changes the 
Setting Menu to the standard operation mode. If you do not 

make your choice within 1 minute, your flashlight exits from the 
Setting Menu into the standard operation mode without saving 
your selection. 

The value by default:  FULL. The maximum full 

stabilization.

Item 7. Setting of Automatic Memorizing Type of Last 

Activated Mode

Entry: when you confirm your choice by tightening/loosening the 
head at blinking for 7 times, which indicates the Item 7 of the 
menu, the flashlight shows through indication the accessible 
alternatives of the automatic memorization types pausing 
between for 3 seconds:

l

 

Activate auto memorization at both lines - 

the flashlight 

blinks once.

l

 

Deactivate auto memorization for the First Line - 

the 

flashlight blinks twice.

l

 

Deactivate auto memorization for the Second Line - 

the 

flashlight blinks 3 times.

l

 

Deactivate auto memorization at both lines - 

the flashlight 

blinks 4 times

.

Selection confirmation: tighten/loosen the head within 1 
second while the required choice is activated or the flashlight 
pauses after it. The flashlight saves your selection and changes 
the Setting Menu to the standard operation mode. If you do not 
make your choice within 1 minute, your flashlight exits from the 
Setting Menu into the standard operation mode without saving 
your selection. 

The value by default:  Activate auto memoriza-

tion at both lines.

Содержание Predator G109.1

Страница 1: ...faultless beam for the distances of 200 meters The diameter of spot is 8 meters for 100 meters of beam distance The full spill is 24 degrees The ultra transparent hardened glass with anti reflective coating which is used in photo lens The recent LED Cree XP G USA is supplied by maximum current of 1 5 amp and due to high efficient heat removal it is not overheated as well as luminous flux drop is m...

Страница 2: ...ody which does not roll and is protected from impacts and scratches The body is developed for the lower weight with sufficient durability The metric threads for better water resistant made precisely for long life using The flashlight has double silicone O rings for each body thread additional O rings for tailcap special form L ring under glass for water resistance improvement The O rings and threa...

Страница 3: ...ra low mode 0 1Lm up to 100 days for 18650 Li Ion 2400mAh l SOS the light flash according to the Morse code up to 3 5 hours for 18650 2400mAh l Beacon 1 flash per 7 seconds at 10 from the maximum brightness up to 30 days for 18650 2400mAh The flashlight is provided with 2 lines of the modes l First Line switching on with the tightened head up to 10 modes of the stabilized light l Second Line switc...

Страница 4: ...ashlight is on and its head is tightened it is required to loosen the head relative to body by turn more than for 1 second then tight the head within 3 seconds and switch on off the flashlight with click This entry is developed to prevent the accidental entry in this mode Brightness selection right after entry in the Brightness Setting the flashlight starts to increase its brightness of the stabil...

Страница 5: ... the Setting Menu into the standard operation mode without saving your selection Item 1 Mode Selection and Setting Entry the flashlight will show the Item 1 by flashing for 1 time when confirming by tightening loosening the head your flashlight shows 5 available modes through indication with the pauses between in the following sequence l Strobe frequent blinking at the same frequency l Firefly swi...

Страница 6: ...n Advanced Settings Armytek Predator Selection confirmation tighten loosen the head within 1 second while the required choice is activated or the flashlight pauses after it The flashlight saves your selection and changes the Setting Menu to the standard operation mode If you do not make your choice within 1 minute your flashlight exits from the Setting Menu into the standard operation mode without...

Страница 7: ...zation the flashlight blinks 3 times Selection confirmation tighten loosen the head within 1 second while the required choice is activated or the flashlight pauses after it The flashlight saves your selection and changes the Setting Menu to the standard operation mode If you do not make your choice within 1 minute your flashlight exits from the Setting Menu into the standard operation mode without...

Страница 8: ...ber and increasing water resistance not corrosive to the rubber If thread is dirty it is required to wipe it dry with clean cloth prior the new lubrication process l If the switch operation is not stable or the rubber button is defected it is required to turn off the rear steel bezel and then turn off the washer counter clockwise with the tweezers or scissors which is set into the rear cover to re...