ARMTEL LS-25(T) Скачать руководство пользователя страница 10

LS-25(T) WEATHERPROOF SPEAKER 

User Manual 

page 8/24 

 

armtel.com 

© Armtel 

 

 [email protected]

 

ENG 

1.5 Design 

1.5.1 LS-25(

Т

) housing is made from antistatic PA and included two part. First part of 

the housing including the speaker and the matching transformer, second – terminal block 

and mounting holes for two cable glands 

М

20

х

1,5.    

1.5.2 The housing is as sealed design with a removable back cover. 
1.5.3 LS-25(T) connect to the signal source by the connection cable. The enclosure has 

two holes for cable glands 

М

20

х

1,5 mounting. Maximum cross-sectional area is 2,5 mm

2

cable diameter (for standard cable gland) − from 5 to 12 mm. For example, HMCD031029/50 

manufactured by Schlemmer Tec or analogue. 

The back cover and organize of the cable glands (one cable gland, one plug) in 

standard version of LS-25(T) are shown on 

Figure 2

. 

 

Figure 2 – The back cover, the cable glands in the standard version of LS-25(

Т

Note

 – According to Customer requirements and capabilities of the manufacturer, the 

standard cable glands can be change to other ones. Quantity (up to 2 pcs.) and types of 

installed cable glands according to the supply contract.  

1.5.4 Installation of LS-25 (T) in the operating site is carried out using the bracket (for  

LS-25(T) are available two bracket systems: Standard Bracket (Antistatic PA) from the 

standard scope of supply or Optional Bracket (Stainless Steel)).  External appearance of  

the LS-25(

Т

) Standard Bracket is shown at 

Figure 3

. External appearance of the LS-25(

Т

Optional Bracket is shown at 

Figure 4

Cable gland

Plug

Back cover

Содержание LS-25(T)

Страница 1: ...ENG LS 25 T Weatherproof speaker ARMT 665230 325UM User Manual 26 40 42 110 2020...

Страница 2: ...armtel com Armtel info armtel com...

Страница 3: ...chemical mining wood processing gas and oil industries including rescue services transport facilities etc Short name of the product LS 25 T Maintenance personnel for LS 25 T shall be appointed by the...

Страница 4: ...DAMAGED COMMUNICATION CABLE To avoid electric shock do not turn on the product with a damaged cables ATTENTION NEVER DISMANTLE THE PRODUCT CONNECTED TO MAINS In order to ensure fire safety follow the...

Страница 5: ...INTENDED USE 13 2 1 Operating limits 13 2 2 Preparation for use 14 2 3 Safety precautions 15 2 4 Action in extreme situations 17 2 5 Operation 18 2 5 1 Activity description 18 2 5 2 General requireme...

Страница 6: ...m into the surrounding space air LS 25 T is designed for outdoor use or in premises in environments with high humidity noise dust and smoke levels including environments with aggressive gases and chem...

Страница 7: ...4 kHz 81 37 Protection degree provided by shells under GOST 14254 2015 IEC 60529 2013 IP code IP67 Maximum weight kg 1 9 Overall dimensions mm 348 3 274 200 The secondary tapping of the built in trans...

Страница 8: ...om 50 to 90 from 84 0 to 106 7 from 630 to 800 The LS 25 withstands without mechanical damage in operating conditions refer to Table 2 when exposed to sinusoidal vibration 25 Hz frequency with peak ac...

Страница 9: ...able 3 Table 3 Scope of supply Identification Name Quanty ty pcs Note ARMT 665230 325 LS 25 T Weatherproof speaker 1 Installation kit Standard Bracket Antistatic PA 1 Optional kit Optional Bracket Sta...

Страница 10: ...chlemmer Tec or analogue The back cover and organize of the cable glands one cable gland one plug in standard version of LS 25 T are shown on Figure 2 Figure 2 The back cover the cable glands in the s...

Страница 11: ...Standard Bracket Antistatic PA Figure 4 External appearance of the LS 25 Optional Bracket Stainless steel 1 5 5 LS 25 T can be mounted on a wall surfaces a ceiling or a freestanding columns 1 5 6 To d...

Страница 12: ...5 Angle of rotation of the bracket 1 5 7 Maximum weight of LS 25 without the brackets is 1 9 kg 1 5 8 Overall dimensions of LS 25 length 348 3 mm height 274 mm width 200 mm see Figure 6 a side view b...

Страница 13: ...he following information name trademark and reference information of the manufacturer product name degree of protection provided by enclosures IP code commercialization mark for products on the market...

Страница 14: ...ference information of the manufacturer handling symbols according to GOST 14192 96 and TR CU 005 2011 commercialization mark for products on the market of Customs Union member states serial number an...

Страница 15: ...4 Cables connected to LS 25 T must be protected from tensile and torsional loads 2 1 5 When connecting several LS 25 T to the voice transmission line the polarity of the connection must be observed N...

Страница 16: ...r package Inspect LS 25 T housing visually no mechanical damages cracks dents etc on the enclosure and the cover Check the presence of all fasteners and sealing elements 2 2 4 Prepare for installation...

Страница 17: ...LATION 2 2 11 Connect LS 25 to the signal source For correct operation of LS 25 use the voltages accordance Table 1 ATTENTION DO NOT APPLY TO THE LS 25 T DC VOLTAGE 2 2 12 Check LS 25 T performance tu...

Страница 18: ...ring operation of LS 25 T it is forbidden to use components that do not correspond to those indicated in the Product Passport 2 3 8 It is allowed to connect the LS 25 T to the signal source only when...

Страница 19: ...emergency in operation LS 25 T 2 4 2 1 In case of emergency in operation perform the following actions disconnect the signal source from the power supply take measures to eliminate the causes of the e...

Страница 20: ...tructed and become familiar with the requirements of this User Manual 2 5 2 2 Putting LS 25 T into operation after installation performing safety measures in full accordance with the regulatory docume...

Страница 21: ...No Rated input voltage of the primary tapping Wire color 6 Common white 8 70 V green 9 100 V red Table 5 Secondary nominal tapping Connection of transformer contacts Rated power of the secondary nomin...

Страница 22: ...is not too low Make sure all terminal connections are securely locked Check connection and lack of short circuit If the problem persists contact the manufacturer The signal is accompanied by a hum Ve...

Страница 23: ...rical installation and other 3 3 Maintenance procedure Maintenance includes as follows Inspect LS 25 T hosing visually no mechanical damages cracks dents etc on the enclosure cover or controls are all...

Страница 24: ...orage the LS 25 T must be installed on pads that prevent contact of the packaged product with soil 4 2 4 Conservation LS 25 T is not provided 4 2 5 LS 25 storage piling up no more 10 levels 4 2 6 Stor...

Страница 25: ...ssure levels at 1W 1m dBSPL Curve Freq O O O O O O O O O O O 500 Hz 1 kHz 2 kHz 4 kHz O BW Dispersion 6dB 117 81 37 47 Directivy factor Q 3 1 4 5 7 7 9 6 DI 4 9 6 5 8 8 9 8 0 30 60 90 120 150 180 150...

Страница 26: ...LS 25 T WEATHERPROOF SPEAKER User Manual page 24 24 armtel com Armtel info armtel com ENG NOTES...

Страница 27: ...armtel com info armtel com Armtel...

Страница 28: ...and physical address Russia 192012 Saint Petersburg Zaporozhskaya str 12 building 1 office 1 2 TECHNICAL SUPPORT 8 800 500 90 17 for calls from Russian Federation 7 812 633 04 02 for international ca...

Отзывы: