Table 48-1. LonWorks Variable List
49
Map Descriptor Name
Data Array
Name
Data Array
Offset
Lon Function Function
Node
Name
SNVT Type
SNVT
option
oFILLSTATUS
BITA
0
NVPO
Server
Lon_1
SNVT_switch
state
oDRAINSTATUS
BITA
1
NVPO
Server
Lon_1
SNVT_switch
state
oCON1
BITA
2
NVPO
Server
Lon_1
SNVT_switch
state
oCON2
BITA
3
NVPO
Server
Lon_1
SNVT_switch
state
oCON3
BITA
4
NVPO
Server
Lon_1
SNVT_switch
state
oCON4
BITA
5
NVPO
Server
Lon_1
SNVT_switch
state
oCOMTYPE
BITB
0
NVPO
Server
Lon_1
SNVT_switch
state
oRH_SELECT
BITB
1
NVPO
Server
Lon_1
SNVT_switch
state
oHL_SELECT
BITB
2
NVPO
Server
Lon_1
SNVT_switch
state
oOUTTEM_SELECT
BITB
3
NVPO
Server
Lon_1
SNVT_switch
state
oNETWORK_ENABLE
BITB
4
NVPO
Server
Lon_1
SNVT_switch
state
oMOD_FILL_ENABLE
BITB
5
NVPO
Server
Lon_1
SNVT_switch
state
oRH_REQUIRE
SINTA
0
NVPO
Server
Lon_1
SNVT_lev_percent
-
oOUTPUT
SINTA
1
NVPO
Server
Lon_1
SNVT_count_f
-
oWATER_LEVEL
SINTA
2
NVPO
Server
Lon_1
SNVT_count_f
-
oRUN_STATUS
SINTA
3
NVPO
Server
Lon_1
SNVT_count_f
-
oBEDLIFE_H
SINTA
4
NVPO
Server
Lon_1
SNVT_count_f
-
oBEDLIFE_M
SINTA
5
NVPO
Server
Lon_1
SNVT_count_f
-
oRUNTIME_H
SINTA
6
NVPO
Server
Lon_1
SNVT_count_f
-
oRUNTIME_M
SINTA
7
NVPO
Server
Lon_1
SNVT_count_f
-
oDRAINTIME_H
SINTA
8
NVPO
Server
Lon_1
SNVT_count_f
-
oDRAINTIME_M
SINTA
9
NVPO
Server
Lon_1
SNVT_count_f
-
oIDLETIME_H
SINTA
10
NVPO
Server
Lon_1
SNVT_count_f
-
oIDLETIME_M
SINTA
11
NVPO
Server
Lon_1
SNVT_count_f
-
oRH_VALUE
SINTA
12
NVPO
Server
Lon_1
SNVT_lev_percent
-
oDUCT_VALUE
SINTA
13
NVPO
Server
Lon_1
SNVT_lev_percent
-
oOUTSIDE_TEMP
SINTA
14
NVPO
Server
Lon_1
SNVT_temp_p
-
oWATER_TEMP
SINTA
15
NVPO
Server
Lon_1
SNVT_temp_p
-
oHEAT_TEMP
SINTA
16
NVPO
Server
Lon_1
SNVT_temp_p
-
oFAULT
SINTA
17
NVPO
Server
Lon_1
SNVT_count_f
-
oCON_NUMBER
SINTA
18
NVPO
Server
Lon_1
SNVT_count_f
-
oHEAT_POWER
SINTA
19
NVPO
Server
Lon_1
SNVT_count_f
-
oLANGUAGE
SINTB
0
NVPO
Server
Lon_1
SNVT_count_f
-
oRH_SET
SINTB
1
NVPO
Server
Lon_1
SNVT_lev_percent
-
oHL_POINT
SINTB
2
NVPO
Server
Lon_1
SNVT_lev_percent
-
oOUTTEMP_H
SINTB
3
NVPO
Server
Lon_1
SNVT_temp_p
-
oOUTTEMP_L
SINTB
4
NVPO
Server
Lon_1
SNVT_temp_p
-
oOUTRH_L
SINTB
5
NVPO
Server
Lon_1
SNVT_lev_percent
-
oRUN_MODE
SINTB
6
NVPO
Server
Lon_1
SNVT_count_f
-
oWATER_TEMP_SET
SINTB
7
NVPO
Server
Lon_1
SNVT_temp_p
-
oBED_LIFE
SINTB
8
NVPO
Server
Lon_1
SNVT_count_f
-
oDRAIN_FREQ
SINTB
9
NVPO
Server
Lon_1
SNVT_count_f
-
oDRAIN_TIME
SINTB
10
NVPO
Server
Lon_1
SNVT_count_f
-
oSENSER_TYPE
SINTB
11
NVPO
Server
Lon_1
SNVT_count_f
-
oPID_DIV
SINTB
12
NVPO
Server
Lon_1
SNVT_count_f
-
oPID_PB
SINTB
13
NVPO
Server
Lon_1
SNVT_count_f
-
oPID_SI
SINTB
14
NVPO
Server
Lon_1
SNVT_count_f
-
oPID_DG
SINTB
15
NVPO
Server
Lon_1
SNVT_count_f
-
oMOD_FILL_FREQ
SINTB
16
NVPO
Server
Lon_1
SNVT_count_f
-
oMOD_FILL_TIME
SINTB
17
NVPO
Server
Lon_1
SNVT_count_f
-
oWATER_TEMP_COMP
SINTB
18
NVPO
Server
Lon_1
SNVT_temp_p
-
oHEAT_TEMP_COMP
SINTB
19
NVPO
Server
Lon_1
SNVT_temp_p
-
iCOMTYPE
BITB_in
0
NVUI
Server
Lon_1
SNVT_switch
state
iRH_SELECT
BITB_in
1
NVUI
Server
Lon_1
SNVT_switch
state
iHL_SELECT
BITB_in
2
NVUI
Server
Lon_1
SNVT_switch
state
iOUTTEM_SELECT
BITB_in
3
NVUI
Server
Lon_1
SNVT_switch
state
iNETWORK_ENABLE
BITB_in
4
NVUI
Server
Lon_1
SNVT_switch
state
iMOD_FILL_ENABLE
BITB_in
5
NVUI
Server
Lon_1
SNVT_switch
state
iLANGUAGE
SINTB_in
0
NVUI
Server
Lon_1
SNVT_count_f
-
iRH_SET
SINTB_in
1
NVUI
Server
Lon_1
SNVT_lev_percent
-
iHL_POINT
SINTB_in
2
NVUI
Server
Lon_1
SNVT_lev_percent
-
iOUTTEMP_H
SINTB_in
3
NVUI
Server
Lon_1
SNVT_temp_p
-
iOUTTEMP_L
SINTB_in
4
NVUI
Server
Lon_1
SNVT_temp_p
-
iOUTRH_L
SINTB_in
5
NVUI
Server
Lon_1
SNVT_lev_percent
-
iRUN_MODE
SINTB_in
6
NVUI
Server
Lon_1
SNVT_count_f
-
iWATER_TEMP_SET
SINTB_in
7
NVUI
Server
Lon_1
SNVT_temp_p
-
iBED_LIFE
SINTB_in
8
NVUI
Server
Lon_1
SNVT_count_f
-
iDRAIN_FREQ
SINTB_in
9
NVUI
Server
Lon_1
SNVT_count_f
-
iDRAIN_TIME
SINTB_in
10
NVUI
Server
Lon_1
SNVT_count_f
-
iSENSER_TYPE
SINTB_in
11
NVUI
Server
Lon_1
SNVT_count_f
-
iPID_DIV
SINTB_in
12
NVUI
Server
Lon_1
SNVT_count_f
-
iPID_PB
SINTB_in
13
NVUI
Server
Lon_1
SNVT_count_f
-
iPID_SI
SINTB_in
14
NVUI
Server
Lon_1
SNVT_count_f
-
iPID_DG
SINTB_in
15
NVUI
Server
Lon_1
SNVT_count_f
-
iMOD_FILL_FREQ
SINTB_in
16
NVUI
Server
Lon_1
SNVT_count_f
-
iMOD_FILL_TIME
SINTB_in
17
NVUI
Server
Lon_1
SNVT_count_f
-
iWATER_TEMP_COMP
SINTB_in
18
NVUI
Server
Lon_1
SNVT_temp_p
-
iHEAT_TEMP_COMP
SINTB_in
19
NVUI
Server
Lon_1
SNVT_temp_p
-
Содержание HumidiClean HC-6100 Series
Страница 28: ...HC6100 Wye Wiring layout 28...
Страница 29: ...HC6100 Delta Wiring layout 29...
Страница 30: ...30 HC6100 PAR Single Phase Wiring Layout...
Страница 31: ...HC6300 Wye Wiring layout 31...
Страница 32: ...HC6300 Delta Wiring layout 32...
Страница 33: ...HC6500 Wye Wiring layout 33...
Страница 34: ...HC6500 Delta Wiring layout 34...
Страница 35: ...35 HC6500 WYE 2 contactors Wiring Layout...
Страница 36: ...36 HC6500 Delta 2 contactors Wiring Layout...
Страница 37: ...HC6700 Wye Wiring layout 37...