Designs, materials, weights and performance ratings
are approximate and subject to change without notice.
Visit
armstrong
international.com for up-to-date information.
Armstrong
International
221 Armstrong Blvd., Three Rivers, Michigan, 49093 - USA
Tel. (269) 279-3602 Fax. (269) 279-3130
Page 3 of 44
Specification Matrix
Specifications
Operating Specifications
Steam Supply Pressure
2-15 PSIG (0.14-1 barg)
Water Supply Pressure
20-150 PSIG (1.4-10 barg)
Minimum Inlet Supply Water Temperature
34°F (1°C)
Set Point Range (DRV)
81-158°F (27-70°C)
Minimum System Recirculation Flow
10 GPM (38 LPM) for EACH DRV80 or DRV50, and 5 GPM (19 LPM) for EACH DRV40
Minimum System Draw Off
0 GPM / LPM
Minimum Distance to First Outlet
25 ft (7.62 m)
Minimum Recirculation Loop Temperature Loss
2°F (1°C)
Control Circuit Fuse
3 A (5A w/ SAGE
™
)
Enclosure Protection Rating (DRV)
NEMA 3S
Signal Cable Fittings (DRV)
3/8” liquid-tight, conduit fitting
Battery (DRV)
Qty. 2, type CR-P2, 6V rating
Power Supply Requirements
120/240 VAC / 50-60 Hz / 1 Ph.
Digital-Flo
®
: Single Heater & Single DRV
Optional
Standard
Optional
Model
Heat
Exchanger
Double-Wall
Tube Bundle
DRV
SAGE
™
For Building
System (BS)
Integration
DF
415
DW
40
BS
DF
535
DW
40
BS
DF
665
DW
50
BS
DF
8120
DW
80
BS
Example of Single-Wall Tube Bundle, with SAGE
™
: DF41540BS
Example of Double-Wall Tube Bundle, without SAGE
™
: DF415DW40
Operational Limitations (all models):
Steam pressure, maximum allowable = 150 PSIG (10 barg)
and maximum operating = 15 PSIG (1 barg)
Water pressure, maximum allowable = 150 PSIG (10 barg)
Setpoint temperature, maximum allowable = 158°F (70°C)
Содержание Digital-Flo DF41540
Страница 45: ...Notes...