Preventive Maintenance – continued
Clean-in-Place Unit Maintenance Details
a. Rite-Qwik™ that remains active may be stored for later use. Test the solution by dropping a calcium antacid tablet
into the tank. Fizzing indicates the solution is still active, and can be returned to the original shipping container via
the CIP tank drain outlet. If the solution does not fizz, it is inactive and not worthy of storing.
b. Unused product can be flushed with water into a sanitary sewer. Used solution may be hazardous as a result of
the pre-existing contaminants present in the equipment being cleaned. Dispose of material in accordance with the
Local, State, Provincial, and Federal regulations for your location.
c. After draining and properly storing or disposing of contents in the CIP unit tank, close the tank drain and fill the CIP
tank with fresh water.
d. Connect a CIP hose to the pump discharge outlet, position to drain, and open ball valve.
e. Perform a brief flush of the CIP tank drain by opening and closing tank drain ball valve.
f. Start CIP unit pump. Immediately stop the CIP unit pump once the tank is empty.
g. Perform manual flush of the second CIP hose. Allow components to air dry.
h. Store the Armstrong CIP unit in a warm and dry place. Do not expose to freezing temperatures.