Water supply
pipe Ø 15mm
copper
Flow regulator
fitted
Integral
isolating
valve
Flexible
hose
FLOW
DIRN
FLOW
DIRN
Flexible
hose
Flexible hose
outlet pipe
Ø 15mm
Filter
fitted
Inline
solenoid
valve
6
4
5
23
21
10
5.2
Plumbing Overview
Once the sensor has been secured to the
panel or mounting surface, consideration
should be given to installing & positioning of
the solenoid valve.
Flexible hoses are supplied for installing on
either side of the solenoid valve as shown.
In the plumbing installation example shown
here, water is being supplied from above, but
can be from any direction.
Observe arrow marking on the solenoid valve
as shown here. Ensure water flows in the
direction indicated.
A standard 15mm compression fitting can
be connected on the plain Ø15 of the lower
flexible hose.
4.
To fit upper hose: First fit the o-ring to the
flow regulator.
5.
Insert the flow regulator into the isolating
valve body right down to the shoulder.
Observe orientation of flow regulator.
6.
Slip the compression nut & olive onto the
Ø15mm supply pipe. Push the isolating valve
onto the supply pipe up to the shoulder. Slide
the olive up to the isolating valve & tighten
the compression nut (23mm A/F) with an
adjustable spanner. Hold the isolating valve
steady (21mm A/F) with a second adjustable
spanner.
INSTALLATION GUIDE continued…