DO NOT
apply heat near these products.
Heat generated by soldering could
damage plastic parts and seals.
25 min.
Lenght depends on valve location
Water supply
pipe Ø 15mm
copper
Full ball
isolation valve
(not supplied)
Filter and flow
regulator fitted
Inline
solenoid
valve
Pre-bended tube
Figure.2
Figure.1
Urinal
inlet
15 mm
compression
pipe fitting
min. R52,5
min. R52,5
4
10
5.2
Plumbing Overview
Once the sensor has been secured to the
panel or mounting surface, consideration
should be given to installing & positioning of
the solenoid valve.
Two sets of standard 15 mm compression fit
-
tings are supplied for installing on either side
of the solenoid valve as shown.
In the plumbing installation example shown in
figure.2, water is being supplied from above,
but can be from any direction.
Observe arrow marking on the solenoid valve
as shown here. Ensure water flows in the
direction indicated.
4. Prepare a standard 15mm copper tube
by bending to 90°with minimum of 52,5mm
radius as shown in figure.1(recommended).
Alternatively use standard 15mm compres-
sion elbow.
INSTALLATION GUIDE continued…