10. 

Dismounting and Disposal

  

WARNING! Risk of injury!

 Never remove the device from a system in 

operation.

 

  Make sure that the system is switched off 

professionally.

Before dismounting:
Check before dismounting, whether the system
•  is switched off,
•  is in a safe and currentless state,
•  is unpressurised and cooled down.

Dismounting:
Pay attention to potentially leaking media. Take ap-
propriate precautions to collect them.

Disposal:
In compliance with the directives 2011/65/EU (RoHS) 
and 2012/19/EU (WEEE), the device must be disposed 
of separately as electrical and electronic waste. Please 
regard legal regulations of the country of distribution.

NO DOMESTIC WASTE!

 

 

The instrument comprises various materials. 
It shall not be disposed of together with do-
mestic waste.

 

Æ

Bring the device to your local recycling plant

or

 

Æ

send the device back to your supplier or to the 
ARMANO Messtechnik GmbH.

Disposal of used batteries:
•  Cover the poles with tape during storage and dis-

posal to avoid short circuits.

•  Dispose of used batteries properly in commercial 

collection boxes or at municipal collection points.

WARNING!  Depending on the medium 

used, residues on the device may cause 
a risk for the user and the environment. 
Therefore, take appropriate precautions 
and dispose of the device properly. 

11. 

Warranty Conditions

The warranty conditions are subject to the statutory 
warranty period of 24 months, valid from the date of 
delivery.
Any warranty claims are excluded in case of improper 
use, modification of or damage to the device. Dam-
aged membranes are not accepted as warranty claim. 
Furthermore, defects resulting from normal wear are 
not subject to warranty services.

12. 

CE Conformity

  The CE marking of the instruments certifies 

the conformity with prevailing EU directives 
for placing products on the market within 
the European Union. The following direc-
tives apply:

 

 

2014/30/EU (EMC)

 

 

2014/68/EU (PED)

 

 

The corresponding declaration of conform-
ity is enclosed or available upon request.

Содержание DPG 2600

Страница 1: ...tly at ARMANO Messtechnik GmbH Location Beierfeld Am Gewerbepark 9 08344 Gr nhain Beierfeld Tel 49 3774 58 0 Fax 49 3774 58 545 mail armano beierfeld com Location Wesel Manometerstra e 5 46487 Wesel G...

Страница 2: ...oroughly be fore operating the digital pressure gauge Disregarding the containing warnings especially the safety instructions may result in danger for people the environment and the device and the sys...

Страница 3: ...other wise any warranty and manufacturer responsibility expires In order to ensure measurement accuracy and du rability of the instrument and to avoid damage the limit values indicated in the technic...

Страница 4: ...cker The nameplate is located on the device It contains the most important technical data and information Figure 1 nameplate Scope of delivery Digital pressure gauge DPG 2600 Calibration certificate O...

Страница 5: ...be operated without batteries us ing only the mains adapter Four NiMH batteries size AAA are installed as standard power supply which can also be recharged via the mains adapter 6 Commissioning Befor...

Страница 6: ...and off A flashing symbol is displayed on the screen during logging Up to 8 logs in CSV format can be downloaded via the RS 232 port optional RS 232 data cable and software BAUD RATE sets the baud ra...

Страница 7: ...instrument in its original pack aging If possible remove the packaging not until installa tion of the device Store the instruments in a dry place not exposed to direct sunlight The storage temperatur...

Страница 8: ...your supplier or to the ARMANO Messtechnik GmbH Disposal of used batteries Cover the poles with tape during storage and dis posal to avoid short circuits Dispose of used batteries properly in commerc...

Страница 9: ...E 2014 30 EU OF THE EUROPEAN PARLIAMENT AND THE COUNCIL from February 26 2014 on the approximation of the laws of the Member States relating to the electromagnetic compatibility short EMC Directive DI...

Страница 10: ...B78 01 22 GB p 10 of 12 www armano messtechnik com Operating Instructions Digital Pressure Gauge DPG 2600...

Страница 11: ...www armano messtechnik com p 11 of 12 GB 01 22 B78 Operating Instructions Digital Pressure Gauge DPG 2600...

Страница 12: ...changes replacement of materials and printing errors excepted ARMANO Messtechnik GmbH Location Beierfeld Am Gewerbepark 9 08344 Gr nhain Beierfeld Tel 49 3774 58 0 Fax 49 3774 58 545 mail armano beier...

Отзывы: