System Control
ARM DDI 0388I
Copyright © 2008-2012 ARM. All rights reserved.
4-43
ID073015
Non-Confidential
Figure 4-23 Configuration Base Address Register bit assignments
To access the Configuration Base Address Register, read or write the CP15 register with:
MRC p15,4,<Rd>,c15,c0,0; Read Configuration Base Address Register
MCR p15,4,<Rd>,c15,c0,0; Write Configuration Base Address Register
4.3.25
TLB lockdown operations
TLB lockdown operations enable saving or restoring lockdown entries in the TLB.
shows the defined TLB lockdown operations.
The Select Lockdown TLB entry for a read operation is used to select the entry that the data read
by a read Lockdown TLB VA/PA/attributes operations are coming from. The Select Lockdown
TLB entry for a write operation is used to select the entry that the data write Lockdown TLB
VA/PA/attributes data are written to. The TLB PA register must be the last written or read
register when accessing TLB lockdown registers.
shows the bit assignment of the
index register used to access the lockdown TLB entries.
Figure 4-24 Lockdown TLB index bit assignments
shows the bit arrangement of the TLB VA Register format.
Figure 4-25 TLB VA Register bit assignments
Base address
31
0
Table 4-50 TLB lockdown operations
Description
Data
Instruction
Select Lockdown TLB Entry for Read
Main TLB Index
MCR p15,5,<Rd>,c15,c4,2
Select Lockdown TLB Entry for Write
Main TLB Index
MCR p15,5,<Rd>,c15,c4,4
Read Lockdown TLB VA Register
Data
MRC p15,5,<Rd>,c15,c5,2
Write Lockdown TLB VA Register
Data
MCR p15,5,<Rd>,c15,c5,2
Read Lockdown TLB PA Register
Data
MRC p15,5,<Rd>,c15,c6,2
Write Lockdown TLB PA Register
Data
MCR p15,5,<Rd>,c15,c6,2
Read Lockdown TLB attributes Register
Data
MRC p15,5,<Rd>,c15,c7,2
Write Lockdown TLB attributes Register
Data
MCR p15,5,<Rd>,c15,c7,2
31
2 1
0
UNK/SBZP
Index
VPN
31
10
0
Process
11
11 10 9
UNK/SBZP
NS
12