Arlyn Scales 3200 Series Скачать руководство пользователя страница 5

 

5

Front Panel / Keyboard 

The front panel has a twelve button, click touch key panel that allows easy menu navigation as well as full text and floating 
point entry. 
The main scale functions are shown in black, menu navigation and floating point numeric entry keys are blue and the 
secondary functions are yellow. 

Tare

Net

Gross

Menu/
 Back

Print

Units

On/Off

Zero

Enter

.

7

8

1

2

3

0

.

9

4

5

6

.

.

sa

mp

l e

.

a

ccu

m.

?

.

.

sh

i

ft

cle

a r

ARLYN

SCALES

320M 1000 x .2 lb.

 

 

Main Function Keys  

ON/OFF 

Press once to place the scale in its normal operating mode. Pressing and holding the key will return the scale 
to the “ready” mode. On battery pack equipped scales, press and hold this key to power it down. 

TARE    

Pressing this key will tare any weight on the platform and switch the scale to the net mode. Holding this key 
down will clear any active tare weight. 

NET/GROSS 

Will toggle the indicator between the net and gross mode. The net mode will show the weight on the platform 
minus any tared weight. 

UNITS   

Pressing this key allows you to step through the various conversions. By default, the conversions available are 
pounds, kilograms, grams and ounces. There are four other conversions available that can be activated in the 
setup menu. This will add troy ounces, pennyweights, grains and a user defined conversion to the list. 

ZERO   

Will zero the indicator. 

Menu Navigation Keys 

MENU/BACK 

Using this key from the weight display will access the setup menu. In all other areas it is used to back out 
from menus or to complete an operation. 

ENTER  

This key is used to select items and to complete operations in the various menus. 

ARROWS 

Are used to navigate and select menu items. 

Secondary Function Keys 

SAMPLE 

In counting scales is used to acquire a quick parts counting sample from the platform. Pressing and holding 
this key down will clear the active sample. 

ACCUM 

In counting scales is used to add the piece count to the accumulate register allowing the totaling of parts. 
Pressing and holding this key will clear the accumulate register. 

? KEY   

Can be used in various areas to call up help screens. In some areas this key needs to be pressed and held. 

SHIFT   

Used by the text-editing screen to toggle caps on/off. 

CLEAR  

Used in some editing screens to clear input lines and numbers. In some areas this key needs to be pressed 
and held. 

NUMBER KEYS Are used in various places to input floating point numbers. 

 

Содержание 3200 Series

Страница 1: ...Digital Scales Series 3200 5200 6200 8200 Instruction Manual Arlyn Scales 59 Second Street East Rockaway NY 11518 516 593 4465 www arlynscales com ...

Страница 2: ...IES 8200 6 SAMPLE ACQUISITION 7 Quick Sample 7 Defining Saving and Editing Samples 7 Deactivating Samples 7 COUNTING PARTS 7 ACCUMULATE FUNCTION 7 TEXT DESCRIPTIONS 8 SYSTEM MEMORY ALLOCATION AND USAGE 8 THE SYSTEM MENU 8 CONFIGURATION AND CALIBRATION 9 PLATFORM ADVANCED SETUP 9 CALIBRATION AND TROUBLESHOOTING 11 Scale reads zero and will not move 11 Scale reading is fluctuating wildly 11 Scale re...

Страница 3: ...ace Software Precautions 1 Prevent inflammables and liquids from entering scale head 2 Always use the included wall transformer when using AC outlet NEVER replace the wall transformer with a plug This could cause electrical shock and severely damage to the scale 3 Allow clearance on all sides of scale platform for accurate weighing 4 Do not drop large loads on scale platform 5 NEVER EXCEED THE RAT...

Страница 4: ...e For the most accurate readings the scale may re acquire a true zero by using the ZERO button prior to weighing Controls and Indicators Main Display Screen The scale is equipped with 128x64 LCD Graphics Display with a wide viewing angle and variable contrast For normal operations you have a choice of viewing weight information from two main screens For parts counting scales two more screens are a...

Страница 5: ... are pounds kilograms grams and ounces There are four other conversions available that can be activated in the setup menu This will add troy ounces pennyweights grains and a user defined conversion to the list ZERO Will zero the indicator Menu Navigation Keys MENU BACK Using this key from the weight display will access the setup menu In all other areas it is used to back out from menus or to compl...

Страница 6: ...he lower menu and then press ENTER A new tare will be added to the list with the default description of Tare XXX The number XXX is assigned by the system by counting up the number of tares and then adding one It is possible that after adding and deleting a few tares that two tares will have the same description This is acceptable albeit confusing and the description can be changed later This new d...

Страница 7: ...n This is acceptable albeit confusing and the description can be changed later This new default sample will have a weight value of 0 00 lb when first created Editing Samples You can edit any sample by using the arrow keys to line up on it and the EDIT function in the lower menu and then press ENTER The next screen will show the sample with it s description and weight value in pounds The lower menu...

Страница 8: ...his leaves 471 slots available for user definitions that can take the form of tares counting samples and other functions Each definition uses memory differently and is outlined below DEFINITION USAGE DEFINITION USAGE Platform 4 slots Print Frame 2 slots Tare 1 slot Text Def 1 slot Counting Sample 1 slot Setpoints 4 slots For a detailed description on your current memory usage access menu SETUP MEN...

Страница 9: ...UT OFF There are two settable options available ACT Activates deactivates the auto shutoff feature TIME Is the time in minutes that the unit will shutoff due to inactivity Any time from 1 to 25 minutes can be used Configuration and Calibration Platform Advanced Setup The scale s operating system revolves around one or more platform definitions that are stored in memory with most scales only having...

Страница 10: ...problem and you can press the ZERO button to return the reading to zero before weighing Zero tracking when enabled will detect small reading changes over time and correct the platform back to zero Consult the service manual for details on setup and configuration Software Filter The raw internal reading from the load sensor contains electronic noise and other factors that can cause the reading to b...

Страница 11: ...or missing pins Check for nicks or cuts on the platform cable Scale reading is different on different areas on the platform On platform scales check that all four level legs are solid against the floor If a level leg is screwed in all the way then the stud from the level leg may be contacting the underside of the platform not allowing the load sensor to flex Check for any mechanical interference I...

Страница 12: ...t scales with multiple platforms only Actv Edit Edit Description Auto Setup Input Source Corner Calibration Span Calibration Resolution Overload Pounds Kilograms Grams Ounces Troy Ounces Pennyweights Grains Carats Auto Zero Zero Tracking Actv Wind ZCnt Software Filter New Del Option Setups See options manual System Scale Description Scale ID Number Auto Inc Weigh Number Display Contrast Memory Sta...

Страница 13: ...ip for a period of one year Arlyn Scales warrants that the equipment sold hereunder will conform to the written specifications authorized by Arlyn Scales Arlyn Scales warrants the equipment against faulty workmanship and defective materials If any equipment fails to conform to these warranties Arlyn Scales will at their option repair or replace such goods returned within the warranty period subjec...

Страница 14: ...ERMS CONDITIONS OR UNDERSTANDING OR AGREEMENTS PURPORTING TO MODIFY THE TERMS OF THIS WARRANTY SHALL HAVE ANY LEGAL EFFECT UNLESS MADE IN WRITING AND SIGNED BY A CORPORATE OFFICER OF ARLYN SCALES AND THE BUYER ...

Отзывы: