4) If your scale comes equipped with ramps, fix them to the floor using the mounting holes provided. This way the ramp will not 
move during normal use. Be careful not to let the scale platform rub up against the ramp or any other surface, as this would 
cause non-repeatability of other inaccuracies.  
5) Plug into 117 VAC wall outlet.   
6) For non-battery pack equipped scales, the scale will run a self-test procedure to check its load sensors and electronic 

circuitry. Upon proper completion, scale will display the prompt (“ready”).  Press the ON/OFF key to activate the unit. Press 
and hold the ON/OFF key to return the scale to the ready state. 

   For battery pack equipped scales, the screen will remain blank until you press the ON/OFF key. To shut the scale down, 

press and hold the ON/OFF key until the display blanks out.  

7)  Allow a five-minute warm-up time for stabilization and most accurate results. Items to be weighed may be placed anywhere 

on the platform,  but if heavy items are to be weighed, it is advisable to place them near the center. Many models are 
equipped with shock absorbers and positive overload stops for protection.  Still, care should be taken to avoid putting 
excessive stress on the load cell system, as when heavy weights are dropped on the platform. It is normal for a small 
amount of drift to occur over periods of time. For the most accurate readings the scale may re-acquire a true zero by using 
the ZERO button prior to weighing. 

Controls and Indicators 

Main Display Screen 

The scale is equipped with 128x64 LCD Graphics Display with a wide viewing angle and variable contrast. For normal 
operations, you have a choice of viewing weight information from two main screens. For parts counting scales, two more 
screens are available. You can switch screens by pressing the MENU key and then press ENTER to accept the “Next Screen” 
menu choice. Doing this will step through the screens shown below in order. For non-counting scales screens 3 and 4 are 
skipped. 
 

 

 
WEIGHT DISPLAY 

Shows the weight on the platform in the current units setting. 

COUNT DISPLAY 

Shows the current piece count on the platform. If there are any totals in the accumulate register it will 
indicate “pcs acc” 

UNITS   

 

Shows the active conversion units. 

NET INDICATOR 

Shows “Net” if the indicator is in net weighing mode. 

STATUS/ZERO   

Shows either “Zr” if the platform is at zero, a bar graph showing how close the scale is to maximum 
capacity or “Ouch!” if the platform is overloaded. 

TARE DESCRIPTION 

Shows the description of the active tare weight. If the tare was taken from the keyboard using the 
TARE key it will show “From Keyboard”. 

TARE WEIGHT   

Shows the weight value of the active tare. 

SAMPLE DESCR 

Shows the description of the active sample weight. If the sample was taken from the keyboard using 
the SAMPLE key it will show “From Keyboard”. 

SAMPLE WEIGHT 

Shows the weight value of the active sample. 

 

Содержание 3200 Series

Страница 1: ...Digital Scales Series 3200 5200 6200 8200 Instruction Manual Arlyn Scales 59 Second Street East Rockaway NY 11518 516 593 4465 www arlynscales com ...

Страница 2: ...IES 8200 6 SAMPLE ACQUISITION 7 Quick Sample 7 Defining Saving and Editing Samples 7 Deactivating Samples 7 COUNTING PARTS 7 ACCUMULATE FUNCTION 7 TEXT DESCRIPTIONS 8 SYSTEM MEMORY ALLOCATION AND USAGE 8 THE SYSTEM MENU 8 CONFIGURATION AND CALIBRATION 9 PLATFORM ADVANCED SETUP 9 CALIBRATION AND TROUBLESHOOTING 11 Scale reads zero and will not move 11 Scale reading is fluctuating wildly 11 Scale re...

Страница 3: ...ace Software Precautions 1 Prevent inflammables and liquids from entering scale head 2 Always use the included wall transformer when using AC outlet NEVER replace the wall transformer with a plug This could cause electrical shock and severely damage to the scale 3 Allow clearance on all sides of scale platform for accurate weighing 4 Do not drop large loads on scale platform 5 NEVER EXCEED THE RAT...

Страница 4: ...e For the most accurate readings the scale may re acquire a true zero by using the ZERO button prior to weighing Controls and Indicators Main Display Screen The scale is equipped with 128x64 LCD Graphics Display with a wide viewing angle and variable contrast For normal operations you have a choice of viewing weight information from two main screens For parts counting scales two more screens are a...

Страница 5: ... are pounds kilograms grams and ounces There are four other conversions available that can be activated in the setup menu This will add troy ounces pennyweights grains and a user defined conversion to the list ZERO Will zero the indicator Menu Navigation Keys MENU BACK Using this key from the weight display will access the setup menu In all other areas it is used to back out from menus or to compl...

Страница 6: ...he lower menu and then press ENTER A new tare will be added to the list with the default description of Tare XXX The number XXX is assigned by the system by counting up the number of tares and then adding one It is possible that after adding and deleting a few tares that two tares will have the same description This is acceptable albeit confusing and the description can be changed later This new d...

Страница 7: ...n This is acceptable albeit confusing and the description can be changed later This new default sample will have a weight value of 0 00 lb when first created Editing Samples You can edit any sample by using the arrow keys to line up on it and the EDIT function in the lower menu and then press ENTER The next screen will show the sample with it s description and weight value in pounds The lower menu...

Страница 8: ...his leaves 471 slots available for user definitions that can take the form of tares counting samples and other functions Each definition uses memory differently and is outlined below DEFINITION USAGE DEFINITION USAGE Platform 4 slots Print Frame 2 slots Tare 1 slot Text Def 1 slot Counting Sample 1 slot Setpoints 4 slots For a detailed description on your current memory usage access menu SETUP MEN...

Страница 9: ...UT OFF There are two settable options available ACT Activates deactivates the auto shutoff feature TIME Is the time in minutes that the unit will shutoff due to inactivity Any time from 1 to 25 minutes can be used Configuration and Calibration Platform Advanced Setup The scale s operating system revolves around one or more platform definitions that are stored in memory with most scales only having...

Страница 10: ...problem and you can press the ZERO button to return the reading to zero before weighing Zero tracking when enabled will detect small reading changes over time and correct the platform back to zero Consult the service manual for details on setup and configuration Software Filter The raw internal reading from the load sensor contains electronic noise and other factors that can cause the reading to b...

Страница 11: ...or missing pins Check for nicks or cuts on the platform cable Scale reading is different on different areas on the platform On platform scales check that all four level legs are solid against the floor If a level leg is screwed in all the way then the stud from the level leg may be contacting the underside of the platform not allowing the load sensor to flex Check for any mechanical interference I...

Страница 12: ...t scales with multiple platforms only Actv Edit Edit Description Auto Setup Input Source Corner Calibration Span Calibration Resolution Overload Pounds Kilograms Grams Ounces Troy Ounces Pennyweights Grains Carats Auto Zero Zero Tracking Actv Wind ZCnt Software Filter New Del Option Setups See options manual System Scale Description Scale ID Number Auto Inc Weigh Number Display Contrast Memory Sta...

Страница 13: ...ip for a period of one year Arlyn Scales warrants that the equipment sold hereunder will conform to the written specifications authorized by Arlyn Scales Arlyn Scales warrants the equipment against faulty workmanship and defective materials If any equipment fails to conform to these warranties Arlyn Scales will at their option repair or replace such goods returned within the warranty period subjec...

Страница 14: ...ERMS CONDITIONS OR UNDERSTANDING OR AGREEMENTS PURPORTING TO MODIFY THE TERMS OF THIS WARRANTY SHALL HAVE ANY LEGAL EFFECT UNLESS MADE IN WRITING AND SIGNED BY A CORPORATE OFFICER OF ARLYN SCALES AND THE BUYER ...