![Arktic KITCHEN LINE 232019 Скачать руководство пользователя страница 124](http://html1.mh-extra.com/html/arktic/kitchen-line-232019/kitchen-line-232019_user-manual_2972944124.webp)
124
GR
Symbol
Name
Type
Mode
Meaning
Up/Switch
Button
Press and hold for min.
3 seconds
Switch ON/OFF
Press and release
Scrolling functions; increasing the value of the se-
lected parameter (In the programming mode)
Down/
Defrosting
Button
Press and hold for min.
3 seconds
Manual defrosting will start
Press and release
Scrolling functions; decreasing the value of the se-
lected parameter (In the programming mode)
Set/Mute
Button
Press and release
Mutes the audible alarm
Press and hold for min.
1 second
Displays/sets the set point
Press and hold for min.
3 seconds
Accesses the parameter setting menu
Aux
Light
Illuminated
The additional output active (service mode only)
Clock (RTC) Light
Illuminated
RTC available, enabled (tEN=1) and at least one
time band has been set (service mode only).
Alarm
Light
Illuminated
Alarm in progress
Cooling
Fan
Light
Illuminated
Fan activated
Blinks
The start of fan is delayed due to external shut-off;
other procedure is in progress
Defrosting
Light
Illuminated
Defrosting in progress
Blinks
The start of defrosting is delayed due to external
shut-off; other procedure is in progress
Compresor Light
Illuminated
Compressor on
Blinks
The start of Compresor is delayed by protective
procedure
Operation of control panel
Changing the set value
• In order to display the set value, press and imme-
diately release the [SET/MUTE] button.
• Press and hold the [SET/MUTE] button for at least
1 seconds to change the set value. The current
set value will be displayed.
• To change the set value, press the [UP/SWITCH]
or [DOWN/DEFROSTING] arrows. To store the
new set value, press the [SET/MUTE] button
again or wait 15 seconds.
Setting the default parameters
To reset the default parameters:
• disconnect power from the instrument;
• reconnect power while holding the [SET/MUTE]
and [DOWN/DEFROSTING] buttons;
• the display will show the message “CF”;
• after a few seconds the instrument starts oper-
ating with the default configuration. Any different
parameter settings will need to be updated.
Warnings: running this procedure overwrites any
custom parameter settings.