Setup mode

2. Press      button.

3. Press      button.

1. Select an alarm 

number.

A1

A2

A3

A4

 or 

A5

2. Turn on the alarm.

3. Set the hour.

4. Set the minute.

To the top 
of the alarm 
setting.

- To follow the gray arrows (       ), press      button.

- To follow the black arrows (       ), press      button.

- To change the settings or numbers in 

italic

, press      or      button.

- To scroll through the numbers, hold down      or      button.

- To cancel a setting and return to the previous level, hold down      button for 1 

second.

- To turn the meter off (in any screen), hold down      button for 3 seconds.

SET mode selection

Alarm

1. Hold down     button

for 2 seconds to 
turn on the meter. 

To the top of 
the HYPO setting.

1. Turn on the 

HYPO flag.

2. Set the 

threshold value.

A HYPO flag 
appears when 
your test results 
are below the 
threshold value.

10 

to 

120 mg/dL

HYPO

Current setting

HYPER

To the top of 
the HYPER setting.

1. Turn on the 

HYPER flag.

2. Set the 

threshold value.

A HYPER flag 
appears when 
your test results 
are above the 
threshold value.

150 

to 

600 mg/dL

Beeper
volume

On1

: Low

On2

: Normal

On3

: High

OFF

: Off

1. Select a setting.

To the top of the 
beeper volume setting.

Date

1. Set the year.

To the top 
of the date 
setting.

2. Select a date 

format.

3. Set the month.

4. Set the day.

d-n

: Day - month

n-d

: Month - day

Time

1. Select a time 

format.

To the top of 
the time setting.

2. Set the hour.

3. Set the minute.

12h

 or 

24h

Current setting

Current setting

Current setting

Current setting

Current setting

Chapter 6  Meter setup

[        

„

 Alarm: Off 

„

 HYPO: Off 

„

 HYPER: Off 

„

 Time: Current local time (default format: 24 h) 

„

 Date: Current local date (default format: day - month) 

„

 Beeper volume: High(3) 

„

 BLE: Off

(See chapter 7 “Using the wireless communication function” to change the “BLE” settings.)

Содержание GLUCOCARD SM

Страница 1: ...e condensation bathrooms drying rooms kitchen etc Do not use the meter after it has been dropped in liquid or liquids have entered inside even if dried afterwards Avoid hand contact with test strip slot on the meter A thermo sensor is housed inside the meter to minimize errors Do not connect the meter to a computer via USB cable during testing The meter may be damaged leading to inaccurate test re...

Страница 2: ...lucose If nothing appears on the screen remove the test strip and insert it back into 2 Touch the tip of the test strip to the drop of blood with blood Accurate test results will not be obtained if you apply your blood to the check window directly The meter counts down After 5 seconds a beep sounds and the test result and date time are shown NOTE For accurate test results touch the test strip to y...

Страница 3: ...ph 5 2 2 Press 9 JQ 3 9 JQ button The result average changes in the order of 7 14 30 60 and 90 day each time button is pressed Three bars appear when there is no past result to be included in the average calculation 4 button 5 To turn off the meter hold down button for 3 seconds 5 4 Deleting all test results You can delete all test results from the memory Remember that results cannot be retrieved ...

Страница 4: ...ow the threshold value 10 to 120 mg dL HYPO Current setting HYPER To the top of the HYPER setting 1 Turn on the HYPER flag 2 Set the threshold value A HYPER flag appears when your test results are above the threshold value 150 to 600 mg dL Beeper volume On1 Low On2 Normal On3 High OFF Off 1 Select a setting To the top of the beeper volume setting Date 1 Set the year To the top of the date setting ...

Страница 5: ...rocedure 2 Select PrG Selection of a different receiving device 1 Select the number of the receiving device 3 Edit the icon assigned optional 2 Select On To the BLE mode selection SUCCESS FAILURE Back to step 3 Check the settings of your receiving device Turning the wireless communication OFF 1 Select OFF To the BLE mode selection Deletion of a receiving device 1 Select the number of the receiving...

Страница 6: ...lf off Chapter 9 System care 9 1 Storing your system After use tightly close the caps of the test strip bottle and control solution bottle to maintain their quality Store your meter test strips control solutions and manuals in your carrying case and keep this in a dry location The correct storage temperatures are 0 to 50 C 32 to 122 F for the meter 1 to 30 C 34 to 86 F for test strips and 2 to 30 ...

Страница 7: ...mometer symbol and cannot be part of your result averages Chapter 11 Technical information Product GLUCOCARDTM Model SM Test item Blood glucose level Sample Fresh capillary whole blood Sample size _ Assay method dehydrogenase FAD GDH based method Mediator hexaammineruthenium III chloride 1 Methoxy PMS Calibration The results are equivalent to plasma glucose concentration capillary plasma reference...

Страница 8: ...uthorized Representative in the European Community Serial number Consult instructions for use Blood glucose meter revision Direct current voltage Catalogue number ISSUED 2015 07 Distributed by A MENARINI Diagnostics Via Sette Santi 3 50131 Firenze Italy Tel 39 XXX XXXXXXX E mail xxxxxx xxxxxxxxxx 47430 07 15 IVD Directive 98 79 EC GLUCOCARD SM Made in Philippines GLUCOCARD SM TEST STRIPS GLUCOCARD...

Отзывы: