Intended use

Intended use for

 Sara Plus

The 

Sara Plus

 is a standing and raising aid for short 

transfers of residents/patients e.g. raising from bed and 

transfer to wheelchairs, or from wheelchair to toilet. 

This equipment is also suitable for rehab exercises 

including walking training when the footboard and 

kneepad are removed. Transfers with the 

Sara Plus

 are 

made indoors in the resident’s/patient’s room, treatment 

rooms, in communal areas or in a bathroom.
The 

Sara Plus 

is intended to be used in hospitals, 

nursing homes or other health care facilities for different 

categories of residents/patients.
The 

Sara Plus

 shall always be handled by a trained 

caregiver, continuously attending to the resident/patient, 

and in accordance with the instructions outlined in the 

Instructions for Use (IFU)

.

The 

Sara Plus

 is intended to be used with specifically 

designed Arjo slings.
When using the transfer/walking sling for the transfer, 

the Safe Working Load is 140 kg (308 lbs). When using 

the same sling for walking practice the Safe Working 

Load is 190 kg (420 lbs).
The 

Sara Plus

 should only be used for the purpose 

specified in the 

IFU

. Any other use is prohibited.

Patient assessment

Before attempting to use 

Sara Plus

, a full clinical 

assessment of the resident/patient condition and 

suitability must be carried out by a qualified person. 
The

 Sara Plus

 is intended 

IRU

 the resident/patient who:

• Sits in a wheelchair
• Is able to partially bear weight on at least one leg
• Has some trunk stability
• Is dependent on the caregiver in most situations
• Needs mobility-maintaining standing exercises

When used in combination with an EPS (Extra Postural 

Support)/BOS sling (Buttocks support standing sling) 

and only for raising and transferring purpose, the 

Sara 

Plus

 is intended 

IRU

the resident/patient who:

• Sits in a wheelchair
• Is dependent on the caregiver in most situations
If the resident/patient does not meet these criteria an 

alternative equipment/system shall be used.

Expected service life

The expected service life is the maximum period of 

useful life as defined by the manufacturer.
The expected service life of the 

Sara Plus

 is ten (10) 

years from the date of manufacture, providing the 

following conditions are adhered to:
• The unit is cared for and serviced in accordance with

“Cleaning and disinfection” 

and 

“Care and

preventive maintenance”

.

• The unit is maintained to the minimum requirements

as published in the 

“Preventive maintenance

schedule”

• The servicing and product care, in accordance with

Arjo requirements, must begin on first use of the unit

by the customer.

For expected service life for slings please refer to the 

IFU

 for the respective sling.

The expected service life for consumable products, such 

as batteries, fuses, seal kits, seat inserts, safety belts, 

padded covers, straps and cords in dependent upon the 

care and usage of the equipment concerned. 

Consumables must be maintained in accordance with 

“Cleaning and disinfection” 

and 

“Care and preventive 

maintenance”

.

The equipment is not suitable for use if it is damaged.

Caution:

Although manufactured to a

high standard the 

Sara Plus

 and its

accessories should not be left for extended

periods in humid or wet areas.
Do not under any circumstances spray the

Sara Plus

 or accessories (excluding

slings) with water e.g. under a shower.

Содержание SARA PLUS

Страница 1: ...Sara Plus KKX52180M EN_21 0 2020 INSTRUCTIONS FOR USE...

Страница 2: ...s improvement we reserve the right to modify designs without prior notice The content of this publication may not be copied either whole or in part without the consent of Arjo WARNING To avoid injury...

Страница 3: ...s legs 10 Scale if available 10 Allowed slings with Sara Plus 10 Commode seat Accessory 11 How to use the Sara Plus 12 General 12 Prepare Sara Plus and patient 12 Use the Standing sling for transfer 1...

Страница 4: ...t occur as a result of any unauthorized modification to its products Support If you require further support please contact Arjo for comprehensive support and maintenance to maximize the long term safe...

Страница 5: ...eds mobility maintaining standing exercises When used in combination with an EPS Extra Postural Support BOS sling Buttocks support standing sling and only for raising and transferring purpose the Sara...

Страница 6: ...is 190kg 420lbs Do not exceed these weight limits Warning It is advisable to familiarise yourself and understand the operation of the various controls and features of the Sara Plus as described in Pro...

Страница 7: ...use 4 steps 1 Visually inspect Sara Plus If any part is damaged do NOT use the product 2 Check the battery level 3 Make sure the green reset button situated on the rear of the mast is pressed i See Fi...

Страница 8: ...3 Dual control panel 14 Hand control 15 System failure lower override knob 16 Label System failure lower override identification 17 Handset cable connection 18 Battery discharge indicator 19 Power on...

Страница 9: ...nadvertently overloaded trying to lift a patient heavier than permitted an automatic cut out operates to prevent the lift raising a load in excess of the safe working load this stops the lift motion a...

Страница 10: ...ce to follow the intended straight line walked by the patient The function is activated by flipping over the steering guide on the rear castor to hold it in position See Fig 6 Arc Rest with handgrips...

Страница 11: ...opened to any variable width See Fig 10 When pressure is released from the button movement stops and the chassis legs remains securely in position Scale if available If your Sara Plus has been suppli...

Страница 12: ...patient has been lifted to a standing or near standing position in the manner previously described See Fig 11 Removal of any clothing can be attended to and the patient is then lowered down onto the c...

Страница 13: ...lowered sufficiently to avoid approaching the patient at eye level and making allowances for the patients arms and any obstructions e g chair arms etc 3 Approach the patient from the front with the li...

Страница 14: ...e attached correctly make adjustments on both cords equally so that any slack is taken up in each cord and the back section of the sling supports the patient comfortably and securely Fig 16 Warning As...

Страница 15: ...nger distance transportation See Fig 21 The patient should be supported by the sling but not pulled forward too much See Fig 18 Note Fig 18 Detail view showing cords cleats Fig 19 If the patient can o...

Страница 16: ...trap repeat for the other side See Fig 22 and Fig 17 for attachment of the cords 2 When both cords are attached correctly make adjustments on both cords equally so that any slack in the cord is taken...

Страница 17: ...es and close the chassis legs then transport the patient to desired position See Fig 26 13 Lower the patient carefully using the hand control or dual control panel 14 When the patient is seated in the...

Страница 18: ...connect the attachment clips to the lugs on the outer sides of the Arc Rest See Fig 28 5 When the patient is ready operate the lift button on the handset or dual control to raise the patient at the s...

Страница 19: ...available refer to the Scale IFU Fig 31 Warning When the Proactive Pad assembly is removed make sure that the attachment bracket is also removed before starting therapy Failure to do so could lead to...

Страница 20: ...empt to open or tamper with the charger unit in any way for any repair the charger must be sent to the manufacturer The mains electricity socket must be easily accessible Should a faulty condition occ...

Страница 21: ...arged This will change to a yellow light as the battery approaches full charge capacity finally changing to a green light when the battery is fully charged 5 Charge the battery until the charger indic...

Страница 22: ...pment needs cleaning or are suspected of being contaminated follow the cleaning and or disinfection procedures recommended below before re using the equipment This is especially important when using t...

Страница 23: ...Commode seat 2 steps 1 Pull the rear edge up sharply to disengage the locating lugs 2 Slide the seat forwards a short distance until clear of the frame tubes and lift away See Fig 34 Attach the Commod...

Страница 24: ...ors Replace as required X S Check that the covers fit correctly and are not damaged Replace as required X S Check for evidence of corrosion Replace as necessary X S Warning The points on this checklis...

Страница 25: ...n in the upper lift arm is tightened Make sure the screws retaining the cord cleats in the Arc Rest are tight Make sure all instruction labels are firmly attached and are readable Examine all exposed...

Страница 26: ...y an obstruction Remove the obstruction and check the Sara Plus thoroughly for damage before continuing the lifting cycle If in doubt use the System failure lower override to return the resident to a...

Страница 27: ...SPL3021 Battery capacity 6 Ah Battery charger part number Note indicates relevant country code SPL3024 Fuse 15 A Thermal overcurrent circuit breaker Fuse PCBA 20 A Fuse battery 30 A Protection class...

Страница 28: ...and Storage Atmospheric pressure 800 hPa to 1060 hPa Operating 500 hPa to 1100 hPa Transport 500 hPa to 1100 hPa Storage End of Life Disposal All batteries in the product must be recycled separately B...

Страница 29: ...28 Dimensions Sara Plus dimensions Dimensions in millimetres equivalent in inches...

Страница 30: ...entification 5 Address and SWL 190 kg 420 lbs 6 Product name 7 Safe working load 190 kg 420 lbs 8 CE mark 9 System failure lower override identification 10 Sling size guide 11 Read operating instructi...

Страница 31: ...duct is protected against insertion of fingers and splashing water Type BF Applied part protection against electrical shockinaccordancewith EN IEC 60601 1 CE marking indicating conformity with Europea...

Страница 32: ...ence in nearby electronic equipment RF emissions CISPR 11 Class B This equipment is suitable for use in all establishments including domestic establishments and those directly connected to the public...

Страница 33: ...z 28 V m 710 745 780 MHz 9V m 810 870 930 MHz 28 V m 1720 1845 1970 2450 MHz 28 V m 5240 5500 5785 MHz 9V m Electrical fast transient burst EN 61000 4 4 1kV SIP SOP ports 100 kHz repetition frequency...

Страница 34: ...Intentionally left blank...

Страница 35: ...22 E mail Italy promo arjo com MIDDLE EAST Arjo Middle East FZ LLC Of ce 908 9th Floor HQ Building North Tower Dubai Science Park Al Barsha South P O Box 11488 Dubai United Arab Emirates Direct 971 48...

Страница 36: ...e ergonomic patient handling personal hygiene disinfection diagnostics and the effective prevention of pressure ulcers and venous thromboembolism we help professionals across care environments to cont...

Отзывы: