background image

 

 

Distance to walls covered by a firewall 
Firewall requirement 

The firewall must be at least 

100 mm thick 

and be made of brick,concrete-stone or light concrete. 

Other materials and structureswith satisfactory documentation may also be used. 

Ceiling protection 

There must be a minimum distance of 

1200 mm

to a combustibleceiling above the fireplace. 

Clearances to furniture and soft furnishings 

We recommend that the stove be installed 800 mm from furniture. Serious consideration should also 
be given to positioning of any furniture that could be adversely affected by heat. The clearances to 
combustible materials in front of the stove should be a minimum of 800mm. When lit, a wood-burning 
stove gets hot and therefore adequate protection must be provided, particularly in situations where 
there is a safety risk to children or the infirm. A suitable safety guard around the stove should be 
considered

 

 

2.4 The chimney

 

This product never connect to any shared chimney. 

An efficient modern stove places heavy demands on the chimney, and  you should have the chimney 
regularly swept and inspected by your approved chimney sweep. 
The cross-sectional area of the chimney (at its narrowest point) must comply with National and Local 
Building  Regulations.  Generally,  the  area  needed  for  a  - 7 -  wood-burning  stove  installation  should 
measure at least113cm

2

(125 mm diameter). 

An over-sized chimney is generally hard to keep warm and results in poor draft. In cases here there is 
an  oversized  masonry  chimney,  it  is  recommended  that  the  chimney  be  lined  using  an  appropriate 
chimney lining system with the correct internal diameter. 
With  respect  to  the  chimney  termination,  all  chimneys  should  terminate  in  accordance  with  national 
and Local Building Regulations. 
Note  that  National  and  Local  Regulations  also  apply  with  regard  to  the  placement  of  chimneys  and 
flues in connection with thatched roofs.   
The chimney or flue system must be equipped with access doors for inspection and cleaning. the size 
of  the  cleaning  door  in  the  chimney  must  at  least  equal  to  that  of  the  cross-sectional  area  of  the 
chimney.  In the event that a chimney  fire occurs resulting from faulty operation or prolonged use of 
damp wood fuel, close the air vents completely and contact your local fire department immediately. 

 

2.5 Pipe connections   

The stove is installed with a 125 mmdiameter flue pipe. This must be an approved thickness. 
The  flue  outlet  for  this  product  is  inside  the  burn  chamber  during  transportation.  You  can  choose 
between  a  top  or  rear  outlet  from  the  flue  pipe.  The  screws  for  fastening  are  in  the  bag  containing 

screws.

Figure 3

 

Содержание Seattle

Страница 1: ...roductions for installation and use Seattle Multi fuel stove Imported and Distributed by Micon Distribution Ltd 1a Hallstown Road Ballinderry Upper Lisburn BT28 2NE Arizona brand exclusively owned by Micon ...

Страница 2: ...secondary air 2 3Stove placement clearance requirements 2 4 The chimney 2 5 Pipe connections 2 6 Connecting to a masonry chimney 2 7 Connecting to a steel chimney 2 8 Draft conditions 3 0 User Manual 3 1 Choice of fuel 3 2Use 3 2 1 Use with wood 3 2 2 Use with solid fuel 3 2 3 Ash Removal 3 3 Maintenance 3 3 1 Cleaning glass 3 3 2 External surface cleaning 3 3 3 Gaskets 3 4 Operational problems tr...

Страница 3: ...eat resistant material is affixed to the product This contains information about identification and documentation for the product Installation introduction with technical data 1 0 Technical data Material Cast iron Finish High temp Resistance paint Fuel Multi fuel Log length max 34 7cm Flue outlet Top and rear Flue pipe dimension Inside 3 125 mm 113cm2 cross section Approx weight 99kgs Dimensions d...

Страница 4: ... packaging can be placed underneath to prevent marring Remove the leg pack from the stove and bolt each leg securely to the underside of the base on the combustion chamber using the bolts provided found inside the stove We recommend that two people perform the assembly and installation procedure 2 2installing this stove The stove and chimney installations MUST comply to all current National and Lo...

Страница 5: ...c must be removed from under the floor plate Requirement for protecting combustible flooring in front of fireplace The dimensions of the heart must be in accordance with national laws and regulations See figure 2 Contact your local building authority regarding restrictions and installation requirements Walls protection Note The side load door must not be used in corner installations if this produc...

Страница 6: ......

Страница 7: ...th National and Local Building Regulations Generally the area needed for a 7 wood burning stove installation should measure at least113cm2 125 mm diameter An over sized chimney is generally hard to keep warm and results in poor draft In cases here there is an oversized masonry chimney it is recommended that the chimney be lined using an appropriate chimney lining system with the correct internal d...

Страница 8: ...taking the chimney straight up and through the ceiling you must comply with National Local Building Regulations or flue manufacturers instructions concerning clearances to combustible materials such as walls floor joists and ceilings The joint between the stove flue collar and the stovepipe must also be sealed using the glass fibre rope provided It is important that the insulated flue system is pr...

Страница 9: ...e blocked On a positive note a properly installed wood burner will give even the most efficient houses a pleasant and natural ventilation 2 8 Draft conditions If smoke spillage occurs when the fire door is opened it is probably due to poor chimney draft This type of stove requires at least 12 pa of chimney draft to achieve satisfactory combustion and smoke spillage prevention However in cases wher...

Страница 10: ...most all kinds of wood you should not fire with wet wood or unseasoned wood Wood ought to be stored under a roof for at least 1 year and preferably 2 years with free access to wind Wood should be chopped as soon as possible after felling if it is to dry quickly The wood can be used once the moisture content is less than 20 During the EN test all stoves are tested with wood with a moisture content ...

Страница 11: ...ntrols The primary air supply where air passes up through the riddling grate is controlled using the lower air control and the secondary air airwash system which is supplied to the combustion over the glass is controlled using the upper air control A third air inlet normally named secondary air provides a constant pre heated air supply to the combustion just above the fire is controlled using the ...

Страница 12: ...given circumstances 3 2 2 Use with solid fuel lighting Figure 4 Slide the top air control to open Open the lower control Lay firelighters or rolled up newspapers on the grate with a reasonable quantity if necessary of dry kindling wood Place a small quantity of solid fuel on top Light the newspaper or firelighters using a long taper and close the door When the fire is burning fiercely add further ...

Страница 13: ...nd removal of residue material We would strongly recommend that you do not leave your stove alit at night when burning wood It harms the environment and constitutes very poor use of the wood as the gases in the wood do not ignite at the low temperature but settle as soot unburned gases in the chimney and stove Extreme conditions such as poor draught in the chimney large quantities of wood or wet w...

Страница 14: ...al to keep the grate free from a heavy build up of ashes This product is equipped with a grate riddling device which is used to shake ashes off the grate into the ash pan Whenever the stove is burning without life when the lower control is open use the riddling lever to clear the grate of surplus ashes If burning solid fuel always empty the ash pan at least once a day or whenever it is full of ash...

Страница 15: ...s painted with heat resistant paint It is best maintained by simply vacuuming it with a soft brush attachment or wiping it down with a dry dust free cloth If the stove is used too vigorously the painted surface may assume a greyish tinge over time but the stove can easily be freshened up with spray paint which is available from your local retailer 3 3 3 Gaskets The gaskets in the door will wear ou...

Страница 16: ...e duct is cold Room is in decompression Burn paper and kindling wood to increase heat In houses equipped with mechanical ventilation open a window until the fire is well established Smokes while burning Draught is insufficien Down draught Room is in decompression Consult a chimney specialist Check that the flue is not obstructed sweep if necessary Install an anti down draught cowl Consult your Dea...

Отзывы: