Flue pipes are placed directly onto the product flue outlet. There is a screw on threefold sides of the
product flue outlet. These are used to fasten the flue pipe.Fasten the flue pipe with screws.
Note! It is important that the joints are completely sealed. Airleakage etc. may lead to
malfunction.
2.6 Connecting to a masonry chimney
A wall sleeve should be bricked securely into the wall of the chimney at the appropriate height and the
stovepipe inserted centrally. The pipe must not extend into the actual chimney opening, but rather must
reach only to the inside of the chimney aperture. The gap between the stovepipe and sleeve must be
sealed using glass fibre packing rope.
2.7 Connecting to a steel chimney
If your installation involves taking the chimney straight up and through the ceiling, you must comply
with National, Local Building Regulations or flue manufacturers instructions concerning clearances to
combustible materials such as walls, floor joists and ceilings. The joint between the stove flue collar
and the stovepipe must also be sealed using the glass fibre rope provided. It is important that the
insulated flue system is properly supported both at ceiling level and at roof level.
THE STOVE
MUST NOT BEAR THE WEIGHT OF THE CHIMNEY SYSTEM
(See chimney manufacturer’s
instructions). Excessive weight on the stove will inhibit expansion and could lead to damage of the
stove top. Damage caused to the stove in this way would not be covered by the manufacturers
guarantee.
In the event that a chimney fire occurs resulting from faulty operation or prolonged use of damp
wood fuel, close the air vents completely and contact your local fire department immediately.
CAUTION: