 PELLET STOKER KMP PX50

ARITERM SWEDEN AB

 

  

Installation Instructions - 

2007.12.14 - 3/16

  Fitting

The PX50 stoker is to be mounted to one of the boiler hatches. The best place is 
often where the oil burner normally goes, but if there is not sufficient room for 
the ashes, the hatch for the wood can be a good alternative. If the hatch is not 
big enough to be opened with the stoker in place, arrangements has to be made 
to facilitate an effortless removal and reassembly. One way is to mount screws in 
threaded holes from the inside of the hatch, and use wing nuts. The stoker is to be 
cleaned from deposits and ashes at least  once a week during the cold season.

Note!

 Contact your local chimney sweeper when installing the stoker

  Fitting the stoker

1.   Decide where to put the stoker. If the hatch can be opened with  

the stoker in situ, this is to be preferred. 

 

Note! The electric supply is to be automatically shut of when the  
hatch is opened.

2.   Make a 160 mm diameter hole in the hatch. Seal off using glass fibre rope  

or a similar high temperature gasket. Fasten the burner,  
using the screw on the top of the mounting flange.

 

Note!

 The hatchet has to be well insulated.

3.   All hatches and valves have to be airtight in order to not allow  

undue draught into the boiler.

4.   After mounting the stoker and sealing the boiler it’s time for the screw feeder.
 

Note! When feeding directly to the burner, the standard feeder (maximum 
length 2,3 m) is to be used. Preferably it should be hung from the ceiling.  
Before connecting feeder and stoker; see section Start och adjustment.

Important!

•   The flue valve, if any, must be kept fully open at all times.
•   All hatchets and flue pipes must be airtight.
This is particularly important if the chimney is tight or there is a low draught for any 
other reason. Otherwise there is a risk of smoke going backwards during startup, 
especially if the stoker is not properly adjusted.

  Screw feeder

Allways observe the following:
•  The feeder inlet opening is not to be less than 100 mm from the bottom  

150 mm from the nearest side wall of the storage bin.

•   The feeder has to be inclined between 40˚ and 50˚ from horizontal. 
•   Attach the feeder thoughly to keep it from working its´ way into the storage bin!

  Temperature sensor

The temperature sensor is to be placed in a submerged tube, alternatively high up 
on the boiler top beneath the insulation. If there is not a suitable fastening point the 
sensor can be glued directly to the metal using an epoxi resin. Note that the sensor 
has to be attached directly to the metal to ensure a stable and exact temperature 
regulation.

  Boiler room and safety

There has to be an inlet aperture to allow air being  drawn in to the room from the 
outside. The free area of the aperture should correspond to the area of the chimney. 

A boiler using air for convection must not use air from the room!

It´s important that the room is clean and free from dirt and dust to prevent fire. 
Combustable materials shall not be cept at a distance closer than 1,5 meters from 
the stoker.
Chemicals are not to be stored in the boiler room, because of fire hazards and  
possible damage of the chimney due to acid fumes.

The door to the boiler room must be kept shut!

Содержание PX50

Страница 1: ...DIRECTIONS FOR INSTALLATION AND USE PX50 ...

Страница 2: ...for start and stop and a control screw to adjust the desired working temperature of the boiler Three control lamps indicate that 1 current is on green above On Off switch stoker is in full power mode green stoker is igniting green blink stoker is standing by green slow blink 2 stoker is in low power mode yellow 3 shut down red shut down in full power mode red green shut down in low power mode red ...

Страница 3: ... connecting feeder and stoker see section Start och adjustment Important The flue valve if any must be kept fully open at all times All hatchets and flue pipes must be airtight This is particularly important if the chimney is tight or there is a low draught for any other reason Otherwise there is a risk of smoke going backwards during startup especially if the stoker is not properly adjusted Screw...

Страница 4: ...wer parts of the chimney If so the flue gas temperature has to be rizen If there is only a small amount of moisture in the upper part installation of a draught pass might be sufficient Alternatively the stoker can be run only in full power mode If large amounts of moisture appears installation of a stainless steel insert tube is the best solution If the draught in the chimney burner reacently stop...

Страница 5: ... be made with the enclosed cables and connectors NOTE The stoker has to be connected to the mains on a manual reset cut out thermostat on the boiler The bulb of the cut out thermostat has to be immersed in the boiler water or other wise located on the boiler where a quick action is guaranteed in case of overheating If there is no thermostat on the boiler an external one has to be installed optiona...

Страница 6: ...about 3 4 of a turn every 20 th second Fine tuning full power In order to get optimal result a flue gas tester must be used Consult your local ditributor It is important to achieve the right mixture between fuel and air to get good economy A few minutes after startup the blaze should have a yellow white colour If it is dark yellow there is too much fuel or too less air A very light blaze indicates...

Страница 7: ... and shunt valve is situated in in the tank the temperature sensor can alternatively be placed on the tank this leading to longer running intervals thus mini mizing the number of starts and stops Placing the temperature sensor on the tank If the temperature sensor is to placed on the storage tank the charging pump system must have capacity enough to cool the boiler off sufficiently Boiler temperat...

Страница 8: ...st two months after installation The burner must be dismantled at least four times per year The outer and inner burner tubes should be separated and cleaned from sintered ashes Dismantle by loosing four screws on the front of the stoker Note that all cables have to be unplugged before removing the cover Safety systems The PX50 stoker meets all current safety regulations and standards There are two...

Страница 9: ...cover and pull the cover backwards 3 Disconnect the white wires from the terminal block no 17 18 and pull the sensor out of its hole to the left of and beneath the ventilator 4 Push the new sensor into the hole until it gets stuck Be sure to align it perpendicular to the surface Reconnect the wires on the terminal block and refit the cover Dismantling the screw feeder 1 Disconnect the cable on the...

Страница 10: ...ormally heating element will glow 1 minute after finished start dose If no glow first check all wires and connections then the glow coil 120 145 Ohms If alright change the ignition controller Fault Cause What to do Stoker doesn t ignite remaining pellets in stoker not scorched Faulty ignition element See section Changing the heating element Fault Cause What to do Stoker stops now and then without ...

Страница 11: ...a Technical data Dimensions outside boiler b x h x d 300 x 310 x 300 mm Dimensions inside boiler Ø x l Ø180 x 200 mm Efficiency ca 95 Output maximum 50 kW Output minimum ca 20 kW Voltage 230 VAC Power consumtion mean under power 50 W Weight 12 kg Length standard screw feeder 1 7 m Accessories and fittings Adaptor plate Adaptor plate with flange Overheat cut out thermostat for boiler Longer screw f...

Страница 12: ...PELLET STOKER KMP PX50 ARITERM SWEDEN AB Installation Instructions 2007 12 14 12 16 Warranty For warranty issues Ariterm Sweden AB refers to our local Distributor ...

Страница 13: ... draught cold Pa Temperature outside C Flue gas temperature max power C CO2 content Chimney draught hot Pa Boiler make model Year manufactured Installed at Name Telephone Address Postal address Sold by Seller Company Address Postal address Telephone Mobile Installed by Assembler Company Address Postal adress Telephone Mobile Installed product Pellet stoker type PX50 ...

Страница 14: ......

Страница 15: ...draught cold Pa Temperature outside C Flue gas temperature max power C CO2 content Chimney draught hot Pa Boiler make model Year manufactured Installed at Name Telephone Address Postal address Sold by Seller Company Address Postal address Telephone Mobile Installed by Assembler Company Address Postal adress Telephone Mobile Installed product Pellet stoker type PX50 ...

Страница 16: ...ation and maintenance the obligations of Ariterm Sweden AB under the warranty regulations are no longer binding Ariterm reserve the right to alter any details and specifications without prior notice Ariterm Sweden AB Flottiljvägen 15 SE 392 41 Kalmar www ariterm se ...

Отзывы: